Enhancement in thermal and electrical characteristics of solar photovoltaic module through a direct contact water jacketed cooling system

被引:2
作者
Sharma, Deepak Kumar [1 ]
Rathod, Manish K. [1 ]
Bhale, Purnanand, V [1 ]
机构
[1] Sardar Vallabhbhai Natl Inst Technol, Dept Mech Engn, Renewable & Sustainable Energy Lab, Surat 395007, India
来源
JOURNAL OF THERMAL ENGINEERING | 2024年 / 10卷 / 02期
关键词
Electrical Efficiency; PV; T; Solar Cell; Temperature; Water Jacketed Cooling System; HEAT-PUMP SYSTEM; PERFORMANCE EVALUATION; COLLECTOR; CLIMATE; DUST; MASS; CELL;
D O I
10.18186/thermal.1448632
中图分类号
O414.1 [热力学];
学科分类号
摘要
Renewable energy resources are vital for addressing the universal concerns of air quality, energy security, and sustainable development. Solar energy has several benefits over other popular renewable energy sources, such as its accessibility and increased predictability. The device used for conversion of solar energy to electrical energy is known as photovoltaic panel, which is highly sensitive to the temperature. A significant reduction in efficiency is observed with an increment in temperature hence cooling of photovoltaic panel is highly desirable. Among the different cooling techniques, water cooling is attractive and widely used due to its good thermal properties and availability. Generally, panel cooling through water circulation in tubing is explored in past, however, these tubing structures are having some limitations such as heat transfer barrier, limited surface area, leakage issues, clogging and cost of material. These issues can be partially resolved by using direct contact water jacket cooling system. Therefore, the present study focuses on in enhancing the thermal and electrical characteristics of the solar photovoltaic module through a direct contact water jacketed cooling system. Initially, a 3D numerical model is developed and the outcome of the numerical model is compared with the experimental work. The results obtained are found in good agreement for solar cell temperature and water outlet temperature. The solar panel performance is investigated with different flow rates such as 0.01, 0.05, 0.1 and 1 cm/s. The direct contact water jacketed cooling system offers simplicity, light weight and cost effectiveness and is found promising over the indirect system. Temperature reduction up to 20 degrees C is observed over uncooled PV panel whereas enhancement in electrical efficiency up to 9.6 % is observed. The cooled PV solar cell maintain 40.2% low temperature compare to uncooled solar cell temperature.
引用
收藏
页码:360 / 374
页数:15
相关论文
共 43 条
  • [1] Experimental and numerical investigation on a solar direct-expansion heat pump system employing PV/T & solar thermal collector as evaporator
    Abbas, Sajid
    Yuan, Yanping
    Hassan, Atazaz
    Zhou, Jinzhi
    Zeng, Chao
    Yu, Min
    Emmanuel, Bisengimana
    [J]. ENERGY, 2022, 254
  • [2] Up-to-date literature review on Solar PV systems: Technology progress market status and R&D ,
    Allouhi, Amine
    Rehman, Shafiqur
    Buker, Mahmut Sami
    Said, Zafar
    [J]. JOURNAL OF CLEANER PRODUCTION, 2022, 362
  • [3] Amelia AR., 2016, ADV SCI ENG INOFRMAT, V6, P682, DOI DOI 10.18517/IJASEIT.6.5.938
  • [4] Performance evaluation of a PV (photovoltaic) module by back surface water cooling for hot climatic conditions
    Bahaidarah, H.
    Subhan, Abdul
    Gandhidasan, P.
    Rehman, S.
    [J]. ENERGY, 2013, 59 : 445 - 453
  • [5] Ozone depletion and global warming: Case for the use of natural refrigerant - a review
    Bolaji, B. O.
    Huan, Z.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 18 : 49 - 54
  • [6] A study on photovoltaic parameters of mono-crystalline silicon solar cell with cell temperature
    Chander, Subhash
    Purohit, A.
    Sharma, Anshu
    Arvind
    Nehra, S. P.
    Dhaka, M. S.
    [J]. ENERGY REPORTS, 2015, 1 (104-109) : 104 - 109
  • [7] Hybrid photovoltaic-thermosyphon water heating system for residential application
    Chow, TT
    He, W
    Ji, J
    [J]. SOLAR ENERGY, 2006, 80 (03) : 298 - 306
  • [8] Assessment of the Operating Temperature of Crystalline PV Modules Based on Real Use Conditions
    Ciulla, Giuseppina
    Lo Brano, Valerio
    Franzitta, Vincenzo
    Trapanese, Marco
    [J]. INTERNATIONAL JOURNAL OF PHOTOENERGY, 2014, 2014
  • [9] Hazardous emissions, global climate change and environmental precautions
    Demirbas, Ayhan
    [J]. ENERGY SOURCES PART B-ECONOMICS PLANNING AND POLICY, 2006, 1 (01) : 75 - 84
  • [10] Experimental research on the performance of household-type photovoltaic-thermal system based on micro-heat-pipe array in Beijing
    Deng, Yuechao
    Quan, Zhenhua
    Zhao, Yaohua
    Wang, Lincheng
    Liu, Zhongliang
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 1039 - 1047