High sensitivity Mach-Zehnder interferometric fiber-optic humidity sensor based on multimode interference enhancement

被引:4
|
作者
Li, Yuzhuo [1 ]
Li, Xisheng [1 ]
Liu, Yin [1 ]
You, Jia [1 ]
Peng, Yunfeng [2 ]
Chen, Hongbing [3 ]
机构
[1] Univ Sci & Technol Beijing, Beijing Engn Res Ctr Ind Spectrum Imaging, Sch Automat & Elect Engn, Beijing 100083, Peoples R China
[2] Commun Engn Univ Sci & Technol Beijing, Sch Comp Sci, Beijing 100083, Peoples R China
[3] Resource Engn Univ Sci & Technol Beijing, Sch Civil, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber-optic humidity sensor; Mach-Zender interferometer; Multi-mode interference; Gelatin film; TEMPERATURE;
D O I
10.1016/j.yofte.2024.103891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Variations in humidity can significantly disrupt the proper functioning of precision instruments and meters across various industrial, medical, and scientific applications, thereby necessitating real-time humidity monitoring. Here, a high sensitivity fiber-optic relative humidity (RH) sensor based on Mach-Zender interferometer (MZI) is proposed and demonstrated. The humidity sensor consists of single-mode fiber (SMF), peanut structure (PS), and multi-mode fiber (MMF). A multi-mode interference (MMI) enhanced fiber-optic MZI was constructed using a SMF-PS-SMF-MMF-SMF-PS-SMF cascade structure to detect small changes in the refractive index (RI) and expansion force of gelatin film caused by humidity variation. PS, as a beam splitter and combiner of MZI, provides the possibility for simple, economical, and efficient manufacturing of the fiber-based part of humidity sensors. The addition of MMF will excite higher-order core and cladding modes, laying the foundation for achieving high-sensitivity fiber-optic humidity sensors. The fiber-optic RH sensor prototype demonstrate a high sensitivity of about 0.633 nm/% RH in the RH range of 50 % RH to 80 % RH, and a low temperature crosssensitivity of 0.165 % RH/degrees C. This sensor has the advantages of safe and easy manufacturing process, low manufacturing cost, and high sensitivity, providing continuous high accuracy humidity measurement results for humidity sensing in different fields.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] High-sensitivity humidity sensor based on Mach-Zehnder interferometer in seven-core fiber
    Shao, Min
    Yu, Yang
    Ma, Xinyuan
    Fu, Haiwei
    Zhang, Wensong
    Lu, Qingqing
    OPTICS COMMUNICATIONS, 2025, 574
  • [22] Fiber-optic sensor based on Mach-Zehnder interferometer for securing entrance areas of buildings
    Nedoma, Jan
    Fajkus, Marcel
    Martinek, Radek
    Mec, Pavel
    Novak, Martin
    Bednarek, Lukas
    Vasinek, Vladimir
    OPTICAL MATERIALS AND BIOMATERIALS IN SECURITY AND DEFENCE SYSTEMS TECHNOLOGY XIV, 2017, 10440
  • [23] MULTIMODE FIBER-OPTIC MACH-ZEHNDER INTERFEROMETER AND ITS USE IN TEMPERATURE-MEASUREMENT
    OKAMOTO, T
    YAMAGUCHI, I
    APPLIED OPTICS, 1988, 27 (15): : 3085 - 3087
  • [24] A Mach-Zehnder interferometric humidity sensor based on waist-enlarged tapers
    Shao, Min
    Qiao, Xueguang
    Fu, Haiwei
    Li, Huidong
    Zhao, Jianlin
    Li, Yan
    OPTICS AND LASERS IN ENGINEERING, 2014, 52 : 86 - 90
  • [25] Fiber-optic seismometer on the basis of Mach-Zehnder interferometer
    Kamenev, Oleg T.
    Kulchin, Yuri N.
    Petrov, Yuri S.
    Khiznyak, Ruslan V.
    Romashko, Roman V.
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 244 : 133 - 137
  • [26] Distributed fiber-optic vibration sensor using a ring Mach-Zehnder interferometer
    Sun, Qizhen
    Liu, Deming
    Wang, Han
    Liu, Hairong
    OPTICS COMMUNICATIONS, 2008, 281 (06) : 1538 - 1544
  • [27] Mach-Zehnder and modified Sagnac-distributed fiber-optic impact sensor
    Chtcherbakov, AA
    Swart, PL
    Spammer, SJ
    APPLIED OPTICS, 1998, 37 (16) : 3432 - 3437
  • [28] Low-coherence fiber-optic sensor ring network based on a Mach-Zehnder interrogator
    Yuan, LB
    Zhou, LM
    Jin, W
    Yang, J
    OPTICS LETTERS, 2002, 27 (11) : 894 - 896
  • [29] Frequency response of distributed fiber-optic vibration sensor based on nonbalanced Mach-Zehnder interferometer
    Wei, Pu
    Shan, Xuekang
    Sun, Xiaohan
    OPTICAL FIBER TECHNOLOGY, 2013, 19 (01) : 47 - 51
  • [30] High Sensitivity Fiber-Optic Strain Sensor Based on Modified Microfiber-Assisted Open-Cavity Mach-Zehnder Interferometer
    Zhang, Hui
    Zhang, Meng
    Kang, Jing
    Zhang, Xudong
    Yang, Jiuru
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (13) : 4556 - 4563