Boosting mold aerosol reduction and dehumidification performance in liquid desiccant systems using airborne ultrasound: An experimental study

被引:1
|
作者
Gu, Yuqian [1 ]
Zhuang, Wenfei [2 ]
Zhong, Ke [1 ]
Yang, Zili [1 ]
机构
[1] Donghua Univ, Sch Environm Sci & Engn, Dept Civil Engn, Shanghai 201620, Peoples R China
[2] Marine Design & Res Inst China, Shanghai 200011, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Airborne ultrasound; Dehumidification; Air disinfection; Mold aerosol; INACTIVATION; SAMPLER; ENHANCEMENT; VENTILATION; DEPOSITION; EFFICIENCY; FIELD; FLOW;
D O I
10.1016/j.buildenv.2024.111956
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor mold exposure in hot-humid regions poses considerable risks to public health and food security. Ensuring safe, durable, and energy-efficient air disinfection is crucial for the air-conditioning field. While liquid desiccant air-conditioning (LDAC) systems eliminate condensation-related mold proliferation, their capability to combat airborne mold spores is limited due to the spores' robust resistance. This paper explores a novel airborne ultrasound-assisted liquid desiccant air-conditioning (US-LDAC) system. Experiments were conducted using culture-based methods to compare the system's disinfection capacities against Aspergillus niger spores, a desiccant-resistant species, under ventilation, liquid desiccation dehumidification, and airborne ultrasoundassisted liquid desiccant dehumidification modes. Moreover, the viability and morphological changes of mold spores exposed to airborne ultrasound, with and without liquid desiccants, were analyzed to verify the disinfection effectiveness and extrapolate the improving mechanisms. The results show that irradiating low-intensity airborne ultrasound ( 127 W, harmless mechanical waves) into the dehumidifier significantly increased the disinfection efficiency by 50 % and the dehumidification rate by over 90 % when airflow passed through the dehumidifier ( 0.4 s). The enhanced disinfection is attributed to ultrasonic cavitation, which facilitates the rupture of the desiccant-captured spores through microstreaming-induced shear forces. Notably, the improvements were more pronounced in humid air and with dilute desiccant solutions, suggesting that efficiency can be maintained with lowered desiccant concentrations. The US-LDAC system was particularly adept at removing mold aerosols (2.1-3.3 mu m) which are easily inhaled. These findings propose a promising avenue for retrofitting existing LDAC systems to effectively reduce airborne molds and enhance dehumidification, thereby protecting indoor air quality.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] A view on the performance comparison between adiabatic and internally-cooled dehumidification processes using liquid desiccant
    Luo, Jielin
    Wang, Qiliang
    Zhang, Yanling
    Yang, Hongxing
    DESALINATION, 2024, 586
  • [42] Performance Study on a Heat Pump Driven Three-stage Liquid Desiccant Deep Dehumidification Processor
    Zhang, Haiqiang
    Liu, Xiaohua
    Jiang, Yi
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 679 - 686
  • [43] Experimental study on a fresh air heat pump desiccant dehumidification system using rejected heat
    Chai, Shaowei
    Zhao, Yao
    Ge, Tianshu
    Dai, Yanjun
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [44] Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system
    Yang, Yu
    Yan, Junwei
    Zhou, Xuan
    Xiao, Liehui
    Huang, Si-Min
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 (131) : 87 - 100
  • [45] Experimental study on the performance of an improved dehumidification system integrated with precooling and recirculated regenerative rotary desiccant wheel
    Su, Minqi
    Han, Xiaoqu
    Chong, Daotong
    Wang, Jinshi
    Liu, Jiping
    Yan, Junjie
    APPLIED THERMAL ENGINEERING, 2021, 199
  • [46] Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance
    Venegas, Tomas
    Qu, Ming
    Wang, Lingshi
    Liu, Xiaobing
    Gluesenkamp, Kyle
    Gao, Zhiming
    ENERGY AND BUILDINGS, 2023, 278
  • [47] Energy and thermal performance of optimised hollow fibre liquid desiccant cooling and dehumidification systems in mediterranean regions: Modelling, validation and case study
    Qu, Ke
    Barreto, Germilly
    Iten, Muriel
    Wang, Yuhao
    Riffat, Saffa
    ENERGY, 2023, 263
  • [48] Numerical and experimental study on internally cooled liquid desiccant dehumidification concerning film shrinkage shape and vapor condensation
    Wen, Tao
    Lu, Lin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 136 : 316 - 327
  • [49] Experimental performance of polymeric air-solution contactors for liquid desiccant systems
    Prieto, Juan
    Ortiga, Jordi
    Coronas, Alberto
    APPLIED THERMAL ENGINEERING, 2017, 121 : 576 - 584
  • [50] Experimental study of internally cooled liquid desiccant dehumidification: Application in Hong Kong and intensive analysis of influencing factors
    Luo, Yimo
    Wang, Meng
    Yang, Hongxing
    Lu, Lin
    Peng, Jinqing
    BUILDING AND ENVIRONMENT, 2015, 93 : 210 - 220