Following Distal Radius Volar Plate Fixation

被引:4
作者
Bachoura, Abdo [1 ,2 ]
Prokuski-Lund, Vanessa [1 ]
Kane, Patrick [1 ]
Zelouf, David S. [1 ]
Osterman, Lee [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Philadelphia Hand Shoulder Ctr, Philadelphia, PA USA
[2] Rothman Orthopaed, 1141 Patterson Ter, Lake Mary, FL 32746 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2024年 / 49卷 / 08期
关键词
Distal radius fracture; fl exor tendon rupture; volar plate; POLLICIS LONGUS TENDON; PRONATOR QUADRATUS REPAIR; NONOPERATIVE TREATMENT; FRACTURES; RUPTURE; POSITION; DESIGN;
D O I
10.1016/j.jhsa.2022.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To investigate patient and radiographic factors that may correlate with the time to flexor tendon rupture following volar plate fixation of distal radius fractures. Methods A total of 31 patients who underwent volar plate removal because of flexor tendon rupture were analyzed. Patient demographics and the interval from operative fixation until rupture were determined retrospectively. Volar tilt and lateral carpal alignment were measured radiographically. The Soong classification was used to grade volar plate prominence. The correlation between the duration to tendon rupture and volar tilt, carpal alignment, and age was evaluated. Results There were 7 men and 24 women. Mean age at the time of hardware removal and flexor tendon management was 66 years (n = 31). Radiographs were classified as Soong 1 (n = 24) and Soong 2 (n = 3). The mean measured volar tilt was -4 degrees (range, -20 degrees-+7 degrees). The mean interval from operative fixation until complete tendon rupture was 4.9 years, (range, 0.3-13.1 years; n = 30). There was no correlation between the time interval to rupture and the magnitude of tilt, carpal alignment, or age at the time of operative fixation. Conclusions Although volar plate prominence was present in all patients with flexor tendon ruptures, radiographic parameters including the degree of dorsal tilt, lateral carpal alignment, and patient age did not correlate with the time interval from fixation to tendon rupture. (J Hand Surg Am. 2024;49(8):736-744. Copyright (c) 2024 by the American Society for Surgery of the Hand. All rights reserved.) Type of study/level of evidence Prognostic IV.
引用
收藏
页码:736 / 744
页数:9
相关论文
共 33 条
[1]   Aging does not alter tendon mechanical properties during homeostasis, but does impair flexor tendon healing [J].
Ackerman, Jessica E. ;
Bah, Ibrahima ;
Jonason, Jennifer H. ;
Buckley, Mark R. ;
Loiselle, Alayna E. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (12) :2716-2724
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   A Prospective Randomized Trial Comparing Nonoperative Treatment with Volar Locking Plate Fixation for Displaced and Unstable Distal Radial Fractures in Patients Sixty-five Years of Age and Older [J].
Arora, Rohit ;
Lutz, Martin ;
Deml, Christian ;
Krappinger, Dietmar ;
Haug, Luzian ;
Gab, Markus .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (23) :2146-2153
[4]   Flexor tendon injuries following plate fixation of distal radius fractures: A systematic review of the literature [J].
Asadollahi S. ;
Keith P.P.A. .
Journal of Orthopaedics and Traumatology, 2013, 14 (4) :227-234
[5]   Distal Radius Volar Plate Design and Volar Prominence to the Watershed Line in Clinical Practice: Comparison of Soong Grading of 2 Common Plates in 400 Patients [J].
Bergsma, Minke ;
Brown, Kimberly ;
Doornberg, Job ;
Sierevelt, Inger ;
Jaarsma, Ruurd ;
Jadav, Bhavin .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (10) :853-859
[6]   FLEXOR POLLICIS LONGUS TENDON RUPTURES AFTER PALMAR PLATE FIXATION OF FRACTURES OF THE DISTAL RADIUS [J].
Casaletto, J. A. ;
Machin, D. ;
Leung, R. ;
Brown, D. J. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) :471-474
[7]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[8]  
Fuller D J, 1973, J Bone Joint Surg Br, V55, P173
[9]   Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons-a randomized controlled study [J].
Goorens, C. K. ;
De Keyzer, P. B. ;
Van Royen, K. ;
Provyn, S. ;
Goubau, J. F. .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (03) :541-548
[10]   The Effects of Pronator Quadratus Repair on Outcomes After Volar Plating of Distal Radius Fractures [J].
Hershman, Stuart H. ;
Immerman, Igor ;
Bechtel, Christopher ;
Lekic, Nikola ;
Paksima, Nader ;
Egol, Kenneth A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (03) :130-133