Portable electrochemical aptasensor for highly sensitive detection of 3,3′,4,4′-tetrachlorobiphenyl

被引:7
作者
Chen, Beibei [1 ]
Wang, Dou [1 ]
Wei, Shusheng [1 ]
Wang, Juan [1 ]
机构
[1] Shanghai Univ Elect Power, Shanghai Key Lab Mat Protect & Adv Mater Elect Pow, Shanghai 200090, Peoples R China
关键词
Hierarchical structure; Modified electrode; Electrochemical biosensor; Aptasensor; PCB77; POLYCHLORINATED-BIPHENYLS; CONGENERS;
D O I
10.1016/j.bios.2024.116434
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Aptamer-based electrochemical sensors are frequently used as independent, surface-functionalized, passive electrodes. However, their sensitivity and detection limits become limited, particularly when the electrode area is reduced to facilitate miniaturization. A mobile phone -based microfluidic electrochemical aptamer sensing platform for 3,3 ' ,4,4 ' -tetrachlorobiphenyl (PCB77) detection was developed in this work. This aptamer sensor utilized Exonuclease I (Exo I) and DNA/AuNPs/horseradish peroxidase (DNA/AuNPs/HRP) nanoprobes as a merged signal amplification method, which resulted in an increase in the electrochemical sensing performance. Sensitive detection of PCB77 was accomplished by functionalizing the hierarchically structured Au@MoS 2 / CNTs/GO modified working/sensing electrode with the specific aptamer. The aptamer sensor was tested with different concentrations of PCB77 within the microfluidic platform. Afterward, the differential pulse voltammograms were recorded using a wireless integrated circuit device. Subsequently, the collected data was transmitted to a smartphone using Bluetooth communication. A detection limit of 0.0085 ng/L was obtained for PCB77 detection, with a detection range from 0.1 to 1000 ng/L. In addition, the detection of PCB77 in spiked water samples validated the possibility of using this aptamer sensor in a real environment, and the aptamer sensor demonstrated high selectivity in distinguishing PCB77 from other potential interfering species. The merging of electrochemical aptamer sensors with purposefully engineered microfluidic and integrated devices in this study is a novel and promising method that provides a dependable platform for on -site applications.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Testicular spermiation failure in rats exposed prenatally to 3,3′,4,4′,5-pentachlorobiphenyl [J].
Wakui, Shin ;
Muto, Tomoko ;
Motohashi, Masaya ;
Kobayashi, Yasuko ;
Suzuki, Yoshihiko ;
Takahashi, Hiroyuki ;
Hano, Hiroshi .
JOURNAL OF TOXICOLOGICAL SCIENCES, 2010, 35 (05) :757-765
[22]   3,3′,4,4′,5-Pentachlorobiphenyl influences mitochondrial apoptosis pathway in granulosa cells [J].
Zhong, Tao ;
Zhang, Jianmei ;
Han, Xiaoying ;
Gongye, Xiaoxiao ;
Lyu, Tianqi ;
Jiang, Menghan ;
Yu, Kaiwei ;
Meng, Xiaoqian ;
Cheng, Dong ;
Lyu, Hui ;
Zhang, Tianliang ;
Zhang, Lei ;
Liu, Shuzhen .
JOURNAL OF CELLULAR BIOCHEMISTRY, 2019, 120 (09) :15337-15346
[23]   Effect of 3,3′,4,5′-tetrachlorobiphenyl and 2,2′,4,4′,5,5′-hexachlorobiphenyl on the induction of hepatic lipid peroxidation and cytochrome P-450 associated enzyme activities in rats [J].
Fadhel, Z ;
Lu, ZJ ;
Robertson, LW ;
Glauert, HP .
TOXICOLOGY, 2002, 175 (1-3) :15-25
[24]   Hydroxylation and dechlorination of 3,3′,4,4′-tetrachlorobiphenyl (CB77) by rat and human CYP1A1s and critical roles of amino acids composing their substrate-binding cavity [J].
Yabu, Miku ;
Haga, Yuki ;
Itoh, Toshimasa ;
Goto, Erika ;
Suzuki, Motoharu ;
Yamazaki, Kiyoshi ;
Mise, Shintaro ;
Yamamoto, Keiko ;
Matsumura, Chisato ;
Nakano, Takeshi ;
Sakaki, Toshiyuki ;
Inui, Hideyuki .
SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 837
[25]   A highly selective electrochemical impedance spectroscopy-based aptasensor for sensitive detection of acetamiprid [J].
Fan, Lifang ;
Zhao, Guohua ;
Shi, Huijie ;
Liu, Meichuan ;
Li, Zhengxin .
BIOSENSORS & BIOELECTRONICS, 2013, 43 :12-18
[26]   Ultra-Sensitive Aptasensor Based on IL and Fe3O4 Nanoparticles for Tetracycline Detection [J].
Shi, Zhaoqiang ;
Hou, Wenjie ;
Jiao, Yancui ;
Guo, Yemin ;
Sun, Xia ;
Zhao, Jing ;
Wang, Xiangyou .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (08) :7426-7434
[27]   Fabrication of a Highly Sensitive Electrochemical Immunosensor for Human Epididymis Protein 4 (HE4) Detection [J].
Qu, Jian ;
Yu, Feng .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11) :11193-11202
[28]   Mixture toxicity effects and uptake of titanium dioxide (TiO2) nanoparticles and 3,3′,4,4′-tetrachlorobiphenyl (PCB77) in juvenile brown trout following co-exposure via the diet [J].
Lammel, Tobias ;
Wassmur, Britt ;
Mackevica, Aiga ;
Chen, Chang-Er L. ;
Sturve, Joachim .
AQUATIC TOXICOLOGY, 2019, 213
[29]   Effects of nonylphenol and 3,3',4,4',5-pentachlorobiphenyl on in vitro oocyte steroidogenesis in redlip mullet, Chelon haematocheilus [J].
Baek, Hea Ja ;
Hwang, In Joon ;
Lee, Young Don ;
Kim, Hyung Bae .
ANIMAL CELLS AND SYSTEMS, 2011, 15 (03) :189-196
[30]   Structure-switching hairpin probe based electrochemical aptasensor for highly sensitive detection of protein [J].
Hu, Xia ;
Zhang, Song-Bai ;
Lu, Ji-Lin ;
Zheng, Li-Ying ;
Geng, Hong-En ;
Qiu, Yan-Qing ;
Huang, Yan-Yan ;
Qiu, Li-Ping ;
Chen, Yuan-Dao .
PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 :114-117