A Validated LC-MS/MS Assay for the Quantification of Cholate Isotopes in Human Serum

被引:2
|
作者
Helmke, Steve M. [1 ]
McRae, Michael P. [2 ]
Christians, Uwe [3 ]
Shokati, Touraj [1 ]
Everson, Gregory T. [1 ]
机构
[1] HepQuant LLC, Denver, CO USA
[2] Custom DX Solut LLC, Houston, TX USA
[3] Univ Colorado, Sch Med, iC42 Clin Res & Dev, Aurora, CO 80237 USA
来源
关键词
CHRONIC HEPATITIS-C; HEPQUANT-SHUNT TEST; SEVERITY INDEX DSI; DISEASE SEVERITY; LIVER-FUNCTION; FIBROSIS; IMPROVEMENT; IMPAIRMENT; CIRRHOSIS; PRESSURE;
D O I
10.1093/jalm/jfae094
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Current methods for evaluating liver health rely on nonspecific blood tests, elastography surrogates for fibrosis, and invasive procedures, none of which directly measure liver function and physiology. Herein we present the analytical validation of a unique, highly sensitive LC-MS/MS assay and dual-sample oral (DuO) cholate challenge test to reliably quantify serial serum concentrations of cholate isotopes administered to patients with liver diseases. The clearance of administered cholate isotopes measured by the assay provides information about liver function and physiology.Methods Analytical method validation of the cholate assay analytes (endogenous unlabeled cholic acid, 24-13C-cholic acid, and 2,2,4,4-D4-cholic acid) in terms of accuracy, precision, analytical sensitivity, analytical specificity, and range of reliable response was completed in human serum samples spiked with quality controls and calibrators in accordance with applicable guidelines. DuO test parameters were validated using samples from 48 subjects representing various liver disease etiologies.Results Accuracy (mean biases) for all analytes ranged from 0.1% to 3.7%. Using a nested components-of-variance design (20 days, 2 runs per day, 2 replicates per sample), total imprecision for all analytes ranged from 2.3% to 8.4%. Lower and upper limits of quantitation were established and validated at 0.1 to 10.0 mu M. Matrix effects and potential interferents did not affect assay performance. DuO test validation met all prespecified acceptance criteria.Conclusions The method validation studies described herein established the performance characteristics in terms of accuracy, precision, analytical sensitivity, analytical specificity, reportable ranges, and reference intervals of the LC-MS/MS cholate assay and DuO test.
引用
收藏
页码:1028 / 1039
页数:12
相关论文
共 50 条
  • [41] DETERMINATION OF LEVONORGESTREL IN HUMAN PLASMA BY A VALIDATED LC-MS/MS METHOD
    Svinarov, D.
    Kasabova, L.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2009, 105 : 67 - 67
  • [42] Fully Validated LC-MS/MS Assay for the Simultaneous Quantitation of Coadministered Therapeutic Antibodies in Cynomolgus Monkey Serum
    Jiang, Hao
    Zeng, Jianing
    Titsch, Craig
    Voronin, Kimberly
    Akinsanya, Billy
    Luo, Linlin
    Shen, Hongwu
    Desai, Dharmesh D.
    Allentoff, Alban
    Aubry, Anne-Francoise
    DeSilva, Binodh S.
    Arnold, Mark E.
    ANALYTICAL CHEMISTRY, 2013, 85 (20) : 9859 - 9867
  • [43] Development and validation of an LC-MS/MS assay for the quantification of dolutegravir extracted from human hair
    Sykes, Craig
    Blake, Kimberly
    White, Nicole
    Schauer, Amanda P.
    Guzman, Bryan B.
    Cottrell, Mackenzie L.
    Tamraz, Bani
    Kashuba, Angela D. M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (29) : 7773 - 7781
  • [44] A novel ultrasensitive LC-MS/MS assay for quantification of intracellular raltegravir in human cell extracts
    Robbins, Brian L.
    Nelson, Sarah R.
    Fletcher, Courtney V.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 378 - 387
  • [45] Development and validation of an LC-MS/MS assay for the quantification of dolutegravir extracted from human hair
    Craig Sykes
    Kimberly Blake
    Nicole White
    Amanda P Schauer
    Bryan B. Guzman
    Mackenzie L. Cottrell
    Bani Tamraz
    Angela D. M. Kashuba
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7773 - 7781
  • [46] LC-MS/MS Method for the Quantification of Infliximab in Human Blood
    Nakamura, H.
    Araki, T.
    Nakamura, T.
    Yamamoto, K.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 724 - 724
  • [47] A robust and validated LC-MS/MS method for the quantification of ramucirumab in rat and human serum using direct enzymatic digestion without immunoassay
    Huang, Wen-si
    Li, Wei-qiang
    Yu, Xiong
    Xue, Ming-zhen
    Yuan, Ya-li
    Chen, Chong
    Wu, Ya-li
    Yu, Jing-hua
    Diao, Xing-xing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1234
  • [48] Validated LC-MS/MS method of Sphingosine 1-phosphate quantification in human serum for evaluation of response to radiotherapy in lung cancer
    Tang, Xiaohui
    Chen, Haisheng
    Chen, Guanxuan
    Duan, Cunxian
    Fan, Qing
    Li, Hui
    Wang, Yanhong
    Li, Zhijun
    Shi, Wenna
    Liu, Yuguo
    THORACIC CANCER, 2020, 11 (06) : 1443 - 1452
  • [49] A combined LC-MS/MS and LC-MS3 multi-method for the quantification of iodothyronines in human blood serum
    Keith H. Richards
    Ray Monk
    Kostja Renko
    Daniel Rathmann
    Eddy Rijntjes
    Josef Köhrle
    Analytical and Bioanalytical Chemistry, 2019, 411 : 5605 - 5616
  • [50] A validated LC-MS/MS method for the quantification of piperacillin/tazobactam on dried blood spot
    Barco, Sebastiano
    Risso, Francesco Maria
    Bruschettini, Matteo
    Bandettini, Roberto
    Ramenghi, Luca A.
    Tripodi, Gino
    Castagnola, Elio
    Cangemi, Giuliana
    BIOANALYSIS, 2014, 6 (21) : 2795 - 2802