First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

被引:0
|
作者
Gallardo-Diaz, E. [1 ]
Mancini, R. C. [1 ]
Clapp, J. [1 ]
Adrian, P. [2 ]
Evans, T. E. [2 ]
Frenje, J. [2 ]
Florido, R. [3 ]
Kruse, M. K. G. [4 ]
Nagayama, T. [5 ]
机构
[1] Univ Nevada, Phys Dept, Reno, NV 89557 USA
[2] MIT, Plasma Sci Fus Ctr, Cambridge, MA 02139 USA
[3] Univ Las Palmas Gran Canaria, iUNAT Dept Fis, Las Palmas Gran Canaria 35017, Spain
[4] Lawrence Livermore Natl Lab, POB 808, Livermore, CA 94550 USA
[5] Sandia Natl Labs, 1611 Innovat Pkwy SE, Albuquerque, NM USA
关键词
INERTIAL-CONFINEMENT-FUSION; PINHOLE-ARRAY; DENSITY; LINE; SPECTROSCOPY; TEMPERATURE;
D O I
10.1063/5.0207826
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (T-e), and electron densities (n(e)) are extracted through the analysis of the spectral region encompassing the Kr He alpha and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at T-e > 2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.
引用
收藏
页数:8
相关论文
共 4 条
  • [1] Design of a Multi-Monochromatic X-ray Imager (MMI) for Kr K-shell line emission
    Gallardo-Diaz, E.
    Mancini, R. C.
    Cliche, D. T.
    Tommasini, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (11)
  • [2] Impact of 3D effects on the characteristics of a multi-monochromatic x-ray imager
    Cliche, Dylan T.
    Mancini, Roberto C.
    APPLIED OPTICS, 2019, 58 (17) : 4753 - 4761
  • [3] An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images
    T.Nagayama
    R.C.Mancini
    D.Mayes
    R.Tommasini
    R.Florido
    HighPowerLaserScienceandEngineering, 2015, 3 (03) : 59 - 65
  • [4] An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images
    Nagayama, T.
    Mancini, R. C.
    Mayes, D.
    Tommasini, R.
    Florido, R.
    HIGH POWER LASER SCIENCE AND ENGINEERING, 2015, 3