摘要
We demonstrate mid -infrared time -domain optical coherence tomography (OCT) with an orientation -patterned GaP optical parametric oscillator. Instantaneous broadband mid -infrared spectra provide reduced scattering for OCT applications including cultural heritage, quality assurance, and security. B -scan calibrations performed across the wavelength tuning range show depth resolutions of 67 mu m at 5.1 mu m and 88 mu m at 10.5 mu m. Volumetric imaging inside a plastic bank card is demonstrated at 5.1 mu m, with a 1 Hz A -scan rate that indicates the potential of stable broadband OPO sources to contribute to mid -infrared OCT.
引用
收藏
页码:2882 / 2885
页数:4
相关论文
共 24 条
[1]  
Bohren C. F., 1983, Absorption and Scattering of Light by Small Particles
[2]   Mid-infrared optical coherence tomography [J].
Colley, Christopher S. ;
Hebden, Jeremy C. ;
Delpy, David T. ;
Cambrey, Alison D. ;
Brown, Robert A. ;
Zibik, Evgeny A. ;
Ng, Wing H. ;
Wilson, Luke R. ;
Cockburn, John W. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (12)
[3]  
Drexler W., 2015, Optical Coherence Tomography. Technology and Applications
[4]   High-resolution mid-infrared optical coherence tomography with kHz line rate [J].
Israelsen, Niels M. ;
Rodrigo, Peter John ;
Petersen, Christian R. ;
Woyessa, Getinet ;
Hansen, Rasmus E. ;
Tidemand-Lichtenberg, Peter ;
Pedersen, Christian ;
Bang, Ole .
OPTICS LETTERS, 2021, 46 (18) :4558-4561
[5]   Real-time high-resolution mid-infrared optical coherence tomography [J].
Israelsen, Niels M. ;
Petersen, Christian R. ;
Barh, Ajanta ;
Jain, Deepak ;
Jensen, Mikkel ;
Hannesschlaeger, Guenther ;
Tidemand-Lichtenberg, Peter ;
Pedersen, Christian ;
Podoleanu, Adrian ;
Bang, Ole .
LIGHT-SCIENCE & APPLICATIONS, 2019, 8 (1)
[6]   Dual-comb spectroscopy in the spectral fingerprint region using OPGaP optical parametric oscillators [J].
Kara, Oguzhan ;
Maidment, Luke ;
Gardiner, Tom ;
Schunemann, Peter G. ;
Reid, Derryck T. .
OPTICS EXPRESS, 2017, 25 (26) :32713-32721
[7]   Reconstruction of visible light optical coherence tomography images retrieved from discontinuous spectral data using a conditional generative adversarial network [J].
Lichtenegger, Antonia ;
Salas, Matthias ;
Sing, Alexander ;
Duelk, Marcus ;
Licandro, Roxane ;
Gesperger, Johanna ;
Baumann, Bernhard ;
Drexler, Wolfgang ;
Leitgeb, Rainer A. .
BIOMEDICAL OPTICS EXPRESS, 2021, 12 (11) :6780-6795
[8]   Long-wave infrared generation from femtosecond and picosecond optical parametric oscillators based on orientation-patterned gallium phosphide [J].
Maidment, Luke ;
Kara, Oguzhan ;
Schunemann, Peter G. ;
Piper, Jonathon ;
McEwan, Kenneth ;
Reid, Derryck T. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2018, 124 (07)
[9]   Molecular fingerprint-region spectroscopy from 5 to 12 μm using an orientation-patterned gallium phosphide optical parametric oscillator [J].
Maidment, Luke ;
Schunemann, Peter G. ;
Reid, Derryck T. .
OPTICS LETTERS, 2016, 41 (18) :4261-4264
[10]   Sub-surface characterisation of latest-generation identification documents using optical coherence tomography [J].
Marques, Manuel J. ;
Green, Robert ;
King, Roberto ;
Clement, Simon ;
Hallett, Peter ;
Podoleanu, Adrian .
SCIENCE & JUSTICE, 2021, 61 (02) :119-129