Indoor Environmental Quality and Effectiveness of Portable Air Cleaners in Reducing Levels of Airborne Particles during Schools' Reopening in the COVID-19 Pandemic

被引:4
|
作者
Villanueva, Florentina [1 ,2 ]
Felgueiras, Fatima [3 ]
Notario, Alberto [1 ,4 ]
Cabanas, Beatriz [1 ,4 ]
Gabriel, Marta Fonseca [3 ]
机构
[1] Univ Castilla La Mancha, Inst Invest Combust & Contaminac Atmosfer, Camino Moledores S-N, Ciudad Real 13071, Spain
[2] Parque Cient & Tecnol Castilla La Mancha, Paseo Innovac 1, Albacete 02006, Spain
[3] Inst Sci & Innovat Mech & Ind Engn, INEGI, Campus FEUP,Rua Dr Roberto Frias 400, P-4200465 Porto, Portugal
[4] Univ Castilla La Mancha, Fac Ciencias & Tecnol Quim, Dept Quim Fis, Ave Camilo Jose Cela S-N, Ciudad Real 13071, Spain
关键词
COVID-19; pandemic; particulate matter; portable air cleaners; school environment; ventilation; VENTILATION; RISK;
D O I
10.3390/su16156549
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Educational buildings tend to fail in the contagion containment of airborne infectious diseases because of the high number of children, for several hours a day, inside enclosed environments that often have inadequate indoor air quality (IAQ) conditions. This study aimed to assess indoor environmental quality and test the effectiveness of portable air cleaners (PACs) in alleviating airborne particle levels in schools of Central-Southern Spain during the period of reopening after the lockdown due to the COVID-19 outbreak. To accomplish this, three sampling campaigns were organized from September to December 2020 to consistently monitor temperature and relative humidity, carbon dioxide, and particulate matter in nineteen classrooms (seven school buildings). Results showed that although the recommendation of maintaining the windows open throughout the day seemed to be effective in promoting, in general, proper ventilation conditions (based on CO2 levels). For the colder campaigns, this practice caused notorious thermal comfort impairment. In addition, a great number of the surveyed classrooms presented levels of PM2.5 and PM10, attributable to outdoor and indoor sources, which exceeded the current WHO guideline values. Moreover, considering the practice of having the windows opened, the installation of 1 unit of PACs per classroom was insufficient to ensure a reduction in particle concentration to safe levels. Importantly, it was also found that children of different ages at different education levels can be exposed to significantly different environmental conditions in their classrooms; thus, the corrective measures to employ in each individual educational setting should reflect the features and needs of the target space/building.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Indoor Air Quality and Health Outcomes in Employees Working from Home during the COVID-19 Pandemic: A Pilot Study
    Roh, Taehyun
    Moreno-Rangel, Alejandro
    Baek, Juha
    Obeng, Alexander
    Hasan, Nishat Tasnim
    Carrillo, Genny
    ATMOSPHERE, 2021, 12 (12)
  • [42] SCHOOL CHILDREN EXPOSURE TO LOW INDOOR AIR QUALITY IN CLASSROOMS DURING COVID-19 PANDEMIC: RESULTS OF A PILOT STUDY
    Kulo, Aida
    Klaric, Sanela
    Cetkovic, Asja
    Blekic, Amina
    Kusturica, Jasna
    Spahic, Nadir
    Sljivo, Armin
    Secic, Damir
    PSYCHIATRIA DANUBINA, 2021, 33 : 83 - 94
  • [43] The Status of Air Quality in the United States During the COVID-19 Pandemic: A Remote Sensing Perspective
    Elshorbany, Yasin F.
    Kapper, Hannah C.
    Ziemke, Jerald R.
    Parr, Scott A.
    REMOTE SENSING, 2021, 13 (03) : 1 - 23
  • [44] Statewide assessment of air quality changes in Florida during the COVID-19 pandemic
    Ghanim, Mohammad Shareef
    Muley, Deepti
    Kianmehr, Peiman
    Kharbeche, Mohamed
    RESULTS IN ENGINEERING, 2023, 20
  • [45] Air quality changes in New York City during the COVID-19 pandemic
    Zangari, Shelby
    Hill, Dustin T.
    Charette, Amanda T.
    Mirowsky, Jaime E.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 742 (742)
  • [46] Air quality characteristics in Wuhan (China) during the 2020 COVID-19 pandemic
    Chen Jiaxin
    Hu Hui
    Wang Feifei
    Zhang Mi
    Zhou Ting
    Yuan Shicheng
    Bai Ruoqiao
    Chen Nan
    Xu Ke
    Huang Hao
    ENVIRONMENTAL RESEARCH, 2021, 195
  • [47] Systematically omitting indoor air quality: sub-standard guidance for shelters, group homes and long-term care in Ontario during the COVID-19 pandemic
    Katz, Amy
    Li, Tianyuan
    James, Llana
    Siegel, Jeffrey
    O'Campo, Patricia
    CRITICAL PUBLIC HEALTH, 2023, 33 (05) : 683 - 696
  • [48] Air quality assessment in Southeast Brazil during COVID-19 pandemic and lockdown: report of increased air pollution
    Bainy, Bruno Kabke
    Paschoal, Ilma Aparecida
    Heuminski de Avila, Ana Maria
    dos Santos, Henrique Oliveira
    CADERNOS DE SAUDE PUBLICA, 2021, 37 (09):
  • [49] Evaluating the impact of air purifiers and window operation upon indoor air quality - UK nurseries during Covid-19
    Zhang, Shuo
    Stamp, Samuel
    Cooper, Elizabeth
    Curran, Katherine
    Mumovic, Dejan
    BUILDING AND ENVIRONMENT, 2023, 243
  • [50] Assessing air quality changes in heavily polluted cities during the COVID-19 pandemic: A case study in Xi'an, China
    Han, Li
    Zhao, Jingyuan
    Gu, Zhaolin
    SUSTAINABLE CITIES AND SOCIETY, 2021, 70