3D ultrasonic full matrix capture imaging for cylindrical scans with wavenumber-domain reconstruction

被引:1
作者
Chen, Mu [1 ,2 ]
Weng, Chenxin [1 ,2 ]
Xu, Xintao [1 ,2 ]
Yang, Keji [1 ,2 ]
Mei, Deqing [1 ,3 ]
Chen, Jian [1 ,2 ]
Jin, Haoran [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Sch Mech Engn, Key Lab Printing Proc & Equipment Zhejiang Prov 3D, Hangzhou 310027, Peoples R China
[3] Zhejiang Ocean Univ, Zhoushan 316022, Peoples R China
基金
中国国家自然科学基金;
关键词
Cylindrical scans; Full matrix capture (FMC); Multilayered structures; 3D ultrasonic imaging; Wavenumber domain; INSPECTION; PIPELINES; ALGORITHM; ARRAYS;
D O I
10.1016/j.ymssp.2024.111528
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonic imaging of cylindrical structures using linear array scanning is a promising nondestructive testing technique. The image resolution in the axial direction of a cylinder has significantly improved through 2D total focusing algorithms employing single -frame full matrix capture (FMC) data. Further enhancement in circumferential resolution is achievable with synthetic aperture focusing using multiple FMC frames. However, conventional methods suffer from time-consuming computational complexity when focusing in both directions. This paper introduces an efficient 3D wavenumber-domain reconstruction method for both axial total and circumferential focusing in cylindrical FMC scans. Key steps include cylindrical scan phase shift migration (CSPSM) for rapid image migration and subsequent deconvolution for high image resolutions. In CSPSM, the imaging model can be simplified for wavefield extrapolation through appropriate distance approximations and the principle of stationary phase. The extrapolation is applicable to multilayered structures, considering constant transmission coefficients. A 3D imaging rate of 5 Hz is attainable with 32 frames of FMC data in the circumferential direction, each acquired by a 32 -element linear array. Experimental results demonstrate achieving an axial resolution of 1.684 mm and a circumferential resolution of 0 . 37 degrees . This method holds potential for real-time 3D imaging in the inspection of wrapped pipelines.
引用
收藏
页数:17
相关论文
共 41 条
  • [31] Synthetic Aperture Focusing of Ultrasonic Data From Multilayered Media Using an Omega-K Algorithm
    Skjelvareid, Martin H.
    Olofsson, Tomas
    Birkelund, Yngve
    Larsen, Yngvar
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (05) : 1037 - 1048
  • [32] A novel design framework of synthetic radial aperture focusing for volumetric transrectal ultrasound imaging
    Song, Hyunwoo
    Kang, Jeeun
    Boctor, Emad M.
    [J]. JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2022, 9 (05) : 1852 - 1865
  • [33] An implementation of synthetic aperture focusing technique in frequency domain
    Stepinski, Tadeusz
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (07) : 1399 - 1408
  • [34] A Modified Omega-K Algorithm for Near-Field MIMO Array-Based 3-D Reconstruction
    Tan, Kai
    Wu, Shiyou
    Liu, Xiaojun
    Fang, Guangyou
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2018, 15 (10) : 1555 - 1559
  • [35] An analytical comparison of ultrasonic array imaging algorithms
    Velichko, Alexander
    Wilcox, Paul D.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (04) : 2377 - 2384
  • [36] Williams Earl G, 2000, FOURIER ACOUSTICS SO
  • [37] Ultrasonic array imaging of multilayer structures using full matrix capture and extended phase shift migration
    Wu, Haiteng
    Chen, Jian
    Yang, Keji
    Hu, Xuxiao
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (04)
  • [38] Synthetic aperture imaging for multilayer cylindrical object using an exterior rotating transducer
    Wu, Shiwei
    Skjelvareid, Martin H.
    Yang, Keji
    Chen, Jian
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (08)
  • [39] Phase Shift Migration with Modified Coherent Factor Algorithm for MIMO-SAR 3D Imaging in THz Band
    Yang, Guan
    Li, Chao
    Wu, Shiyou
    Zheng, Shen
    Liu, Xiaojun
    Fang, Guangyou
    [J]. REMOTE SENSING, 2021, 13 (22)
  • [40] A Modified Wavenumber Algorithm of Multi-Layered Structures with Oblique Incidence Based on Full-Matrix Capture
    Yu, Bei
    Jin, Haoran
    Mei, Yujian
    Chen, Jian
    Wu, Eryong
    Yang, Keji
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (22):