Effect of cement volume on biomechanical response of a spine segment treated with a PEEK polymer implant: a finite element comparative study with vertebroplasty

被引:0
作者
Vienney, Cecile [1 ]
Hambli, Ridha [2 ]
De Leacy, Reade [3 ]
Cornelis, Francois H. [4 ,5 ]
机构
[1] Hyprevent Res & Dev, Pessac, France
[2] Univ Orleans, Univ Tours, INSA CVL, LaMe, Orleans, France
[3] Icahn Sch Med Mt Sinai, Neurosurg, New York, NY USA
[4] Mem Sloan Kettering Canc Ctr, New York, NY USA
[5] Weill Cornell Med Coll, Radiol Dept Radiol, New York, NY USA
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
lumbar spine; vertebral compression fractures; implant; vertebroplasty; cement; dose; finite element; BONE-CEMENT; PERCUTANEOUS VERTEBROPLASTY; VERTEBRAL FRACTURES; STIFFNESS; AUGMENTATION; MODEL; BODY;
D O I
10.3389/fbioe.2024.1399851
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In the current study, a 3D finite element study was performed to investigate the biomechanical response of an osteoporotic spine segment treated with a novel transpedicular implant (V-STRUT (c), Hyprevention, France) made of PEEK (polyetheretherketone) material combined with either injections of 2, 3, 4, 5 and 6 cc of cement. The objective was to assess numerically the biomechanical performance of the implant in combination with different doses of the injected bone cement and to compare its performance with the gold standard vertebroplasty (VP) technique. A female (69 yo) was selected and a 3D finite element model of an osteoporotic spine segment was built based on a Computed Tomography (CT) scan performed from T12 to L2 with corresponding intervertebral discs and ligaments. A heterogeneous distribution of bone material properties was assigned to the bone using grey scale levels. Bilateral ellipsoid geometries of the inserted cement were retained for the V-STRUT and VP models based on experimental observation performed on different patients treated with the V-STRUT device. The current study demonstrated an optimal dose of 4 cc of bilaterally injected cement for the V-STRUT and VP techniques to restore the treated segment and confirmed that the V-STRUT device in combination with bone cement is superior to VP alone in establishing the normal stiffness and in reducing the applied stress to the immediately adjacent vertebral levels.
引用
收藏
页数:12
相关论文
共 26 条
  • [21] Effect of bone cement augmentation with different configurations of the dual locking plate for femoral allograft fixation: finite element analysis and biomechanical study
    Wisanuyotin, Taweechok
    Paholpak, Permsak
    Sirichativapee, Winai
    Sirichativapee, Wilasinee
    Kosuwon, Weerachai
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [22] Effect of bone cement augmentation with different configurations of the dual locking plate for femoral allograft fixation: finite element analysis and biomechanical study
    Taweechok Wisanuyotin
    Permsak Paholpak
    Winai Sirichativapee
    Wilasinee Sirichativapee
    Weerachai Kosuwon
    Journal of Orthopaedic Surgery and Research, 18
  • [23] Comparative biomechanical analysis of rigid vs. flexible fixation devices for the lumbar spine: A geometrically patient-specific poroelastic finite element study
    Khalaf, Kinda
    Nikkhoo, Mohammad
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 212
  • [24] Biomechanical effect of C5-C6 intervertebral disc degeneration on the human lower cervical spine (C3-C7): a finite element study
    Rahman, Waseem Ur
    Jiang, Wei
    Zhao, Fulin
    Li, Zhijun
    Wang, Guohua
    Yang, Guanghui
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (07) : 820 - 834
  • [25] Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
    Kanneganti, Krishna Chaitanya
    Vinnakota, Dileep Nag
    Pottem, Srinivas Rao
    Pulagam, Mahesh
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02) : 161 - 167
  • [26] Analysis of the Effect of Thread Depth in Four Different Thread Designs on the Stress Distribution at the Implant-bone Interface Using Finite Element Analysis - A Comparative Three-Dimensional In vitro Study
    Patwari, Swati
    Sahu, Jeeban
    Samanta, Satyaki
    Bharti, Shreya
    Saha, Dipanwita
    Manna, Rohan
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2024, 16 (01) : 48 - 54