Case report: Endobronchial closure of postoperative bronchopleural fistula with embolization coil: a sandwich-like approach

被引:0
|
作者
Bai, Yang [1 ]
Chi, Jing [1 ]
Wang, Hansheng [2 ]
Li, Yishi [1 ]
Guo, Shuliang [1 ]
机构
[1] Chongqing Med Univ, Affiliated Hosp 1, Dept Resp & Crit Care Med, Chongqing, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Dept Radiol, Chongqing, Peoples R China
关键词
bronchopleural fistula; Embolization Coil; bronchoscopic treatment; case series; interventional pulmonary; OCCLUSION; MANAGEMENT; RISK;
D O I
10.3389/fmed.2024.1333157
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Embolization Coil has been reported to effectively treat postoperative bronchopleural fistula (BPF). Little detailed information was available on computer tomography (CT) imaging features of postoperative BPF and treating procedures with pushable Embolization Coil.Objective We aimed to specify the imaging characteristics of postoperative BPFs and present our experience treating them with the pushable Embolization Coil.Methods Six consecutive patients (four males and two females aged 29-56 years) diagnosed with postoperative BPF receiving bronchoscopic treatment with the pushable Nester (R) Embolization Coil (Cook Medical, Bloomington, Indiana) were included in this single-center, retrospective study. Multiplanar reconstruction of multidetector CT scans was reviewed for the presence, location, size, and radiological complications of each BPF, including air collection, pneumothorax, bronchiectasis, and chest tube. Using standardized data abstraction forms, demographic traits and clinical outcomes were extracted from the medical files of these patients.Results The underlying diseases for lung resection surgery were pulmonary tuberculosis (n = 3), lung adenocarcinoma (n = 2), and pulmonary aspergillosis (n = 1). All patients had air or air-fluid collection with chest tubes on radiological findings. Multiplanar reconstruction identified the presence of postoperative BPF in all patients. Five fistulas were central, located proximal to the main or lobar bronchus, while one was peripheral, distant from the lobar bronchus. Fistula sizes ranged from 0.8 to 5.8 mm. Subsequent bronchoscopy and occlusion testing confirmed fistula openings in the bronchial stump: right main bronchus (n = 1), right upper lobe (n = 2), and left upper lobe (n = 3). The angioplasty catheter-based procedure allows precise fistula occlusion "like a sandwich" with the pushable Embolization Coil. Five patients with BPF sizes ranging from 0.8 to 1.5 mm were successfully treated with a pushable Embolization Coil, except for one with a BPF size of 5.8 mm. No adverse events or complications were observed throughout follow-up, ranging from 29 to 1,307 days.Conclusion The pushable Nester (R) Embolization Coil seems a minimally invasive, cost-effective, and relatively easy-to-perform bronchoscopic treatment for postoperative BPF with a size less than 2 mm. Further studies are required to ensure the use of pushable Embolization Coil in treating postoperative BPF.
引用
收藏
页数:7
相关论文
共 24 条
  • [1] Endobronchial closure of the bronchopleural fistula with the ventricular septal defect occluder: a case series
    Bai, Yang
    Li, Yishi
    Chi, Jing
    Guo, Shuliang
    BMC PULMONARY MEDICINE, 2021, 21 (01)
  • [2] Endobronchial closure of the bronchopleural fistula with the ventricular septal defect occluder: a case series
    Yang Bai
    Yishi Li
    Jing Chi
    Shuliang Guo
    BMC Pulmonary Medicine, 21
  • [3] Endobronchial Valves for Treatment of Bronchopleural Fistula in Granulomatous Polyangitis A Longitudinal Case Report
    Venkatappa, Neethi
    Fadul, Rafid
    Raymond, Daniel
    Cicenia, Joseph
    Gildea, Thomas R.
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2013, 20 (02) : 186 - 188
  • [4] Endobronchial management of bronchopleural fistula using vascular plug device—a case report
    Avinash A. Gutte
    Saurabh Dembla
    The Egyptian Journal of Bronchology, 2022, 16
  • [5] Closure of Bronchopleural Fistula with Mesenchymal Stem Cells: Case Report and Brief Literature Review
    Zeng, Yiming
    Gao, Hong-Zhi
    Zhang, Xiao-Bin
    Lin, Hui-Huang
    RESPIRATION, 2019, 97 (03) : 273 - 276
  • [6] SUCCESSFUL CLOSURE OF BRONCHOPLEURAL FISTULA WITH ADHESIVE TISSUE - CASE-REPORT
    ENG, J
    SABANATHAN, S
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 24 (02): : 157 - 159
  • [7] Endobronchial management of bronchopleural fistula using vascular plug device-a case report
    Gutte, Avinash A.
    Dembla, Saurabh
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2022, 16 (01)
  • [8] Surgically intractable bronchopleural fistula treated with endobronchial valve insertion by isolating the tract with indigo carmine: A case report
    Zo, Sungmin
    Song, Ju Yeun
    Kim, Bo-Guen
    Jeong, Byeong-Ho
    Jeon, Kyeongman
    Cho, Jong Ho
    Kim, Hojoong
    RESPIRATORY MEDICINE CASE REPORTS, 2020, 29
  • [9] Inverted Placement of Endoscopic One-Way Endobronchial Valve Combined with Gelfoam in the Closure of Bronchopleural Fistula with Empyema in a Mechanically Ventilated Patient: A Case Report
    Liu, Jie
    Li, Chun
    Liu, Zilong
    Ye, Ling
    Shen, Qinjun
    Hong, Qunying
    Song, Yuanlin
    Ye, Maosong
    RESPIRATION, 2024, 103 (03) : 166 - 170
  • [10] Pedicled gastric seromuscular patch for one-stage closure of a bronchopleural fistula: a case report
    Jun Suzuki
    Hiroyuki Oizumi
    Hirohisa Kato
    Akira Hamada
    Hikaru Watarai
    Kenta Nakahashi
    Takayuki Sasage
    Mitsuaki Sadahiro
    Surgical Case Reports, 4 (1)