A review regarding the article 'Effectiveness of mechanical circulatory support devices in reversing pulmonary hypertension among heart transplant candidates: A systematic review.

被引:0
作者
Li, Hu [1 ]
Li, Jinfeng [2 ]
Huang, Jianxin [1 ]
Jiang, Danfeng [1 ]
机构
[1] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Sch Med, Dept Anesthesiol, Chengdu 610072, Sichuan, Peoples R China
[2] Chengdu Seventh Peoples Hosp, Dept Anesthesiol, Chengdu 610072, Sichuan, Peoples R China
关键词
Pulmonary hypertension; Mechanical circulatory support; Left ventricular assist devices; Heart transplantation;
D O I
10.1016/j.cpcardiol.2024.102614
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pulmonary hypertension (PH) with high pulmonary vascular resistance (PVR) is a very often diagnosed contraindication for orthotopic heart transplantation (OHT). It is a direct consequence of left ventricle failure characterized by high diastolic pressure obstructing the collection of blood from the pulmonary vessels. The occurrence of this situation grows with the increasing time of waiting for OHT, and with the progression of heart failure. Mechanical circulatory support (MCS) devices, particularly left ventricular assist devices (LVADs), have emerged as pivotal interventions for patients with fixed PH, offering a potential bridge to transplantation. The pathophysiological impact of PH in heart transplant candidates is profound, as it is associated with increased perioperative risk and heightened mortality post-transplantation. The selection of heart transplant candidates thus mandates a careful evaluation of PH, with an emphasis on distinguishing between reversible and fixed forms of the condition. Reversible PH can often be managed with medical therapies; however, fixed PH presents a more daunting challenge, necessitating more aggressive interventions like MCS. Patients are supported with LVADs until evidence of pulmonary afterload reversal is evident and then can be considered for heart transplantation. However, in those who are non-responders or have complications while being supported, their option for transplant is revoked. Despite these advancements, the heterogeneity of MCS devices and their mechanisms of action necessitates a nuanced understanding of their efficacy.
引用
收藏
页数:3
相关论文
共 5 条
[1]   Effectiveness of mechanical circulatory support devices in reversing pulmonary hypertension among heart transplant candidates: A systematic review [J].
Albulushi, Arif ;
Al-Riyami, Mohammed B. ;
Al-Rawahi, Najib ;
Al-Mukhaini, Mohammed .
CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (07)
[2]   Evolution and Current Circumstances of Heart Transplants: Global and Mexican Perspective [J].
Rangel-Ugarte, Paula-Mariana ;
Ramirez-Castaneda, Serafin ;
Mendoza-Lopez, Abril-Carolina ;
Gonzalez-Hermosillo, Leslie-Marisol ;
Flores-Calderon, Octavio ;
Salazar-Hernandez, Ignacio ;
Ramirez-Castaneda, Alberto ;
Roldan-Valadez, Ernesto .
CURRENT PROBLEMS IN CARDIOLOGY, 2022, 47 (10)
[3]   Right ventricle-pulmonary artery coupling in pulmonary artery hypertension its measurement and pharmacotherapy [J].
Sandeep, Bhushan ;
Cheng, Han ;
Yan, Yifan ;
Huang, Xin ;
Wu, Qinghui ;
Gao, Ke ;
Xiao, Zongwei .
CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (04)
[4]   Revisiting Pulmonary Hypertension in the Era of Temporary Mechanical Circulatory Support - Literature Review and Case-Based Discussion [J].
Sharma, Shriya ;
Ruiz, Jose ;
Paghdar, Smit ;
Desai, Smruti ;
Goswami, Rohan .
TRANSPLANTATION PROCEEDINGS, 2023, 55 (10) :2462-2469
[5]   Mechanical circulatory support is effective to treat pulmonary hypertension in heart transplant candidates disqualified due to unacceptable pulmonary vascular resistance [J].
Zakliczynski, Michal ;
Pacholewicz, Jerzy ;
Copik, Izabela ;
Maruszewski, Marcin ;
Hrapkowicz, Tomasz ;
Przybylski, Roman ;
Zembala, Marian .