Effects of Cataract on Optic Nerve Head and Macular Analysis Using Optical Coherence Tomography

被引:0
作者
Park, Chanjoon [1 ]
Jung, Kyoung In [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Ophthalmol, Seoul, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2024年 / 65卷 / 07期
关键词
Cataract; Glaucoma; Optic nerve heads; Optical coherence tomography; FIBER LAYER THICKNESS; DOMAIN; SURGERY; REMOVAL; STRATUS; ERRORS;
D O I
10.3341/jkos.2024.65.7.442
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the impact of cataract on optic nerve head (ONH) parameters (disc area, rim area, average cup/disc ratio, vertical cup/disc ratio, cup volume), peripapillary retinal nerve fiber layer (pRNFL) thickness, and macular ganglion cell-inner plexiform layer (mGC-IPL) thickness in patients with glaucoma and in a control group. Methods: A retrospective analysis was conducted on medical records from January to December 2021 for individuals undergoing cataract surgery. This group included normal, glaucoma suspects, and glaucoma patients, totaling 44 individuals and 63 eyes. Measurements of ONH parameters, pRNFL thickness, and mGC-IPL thickness were taken using spectral-domain optical coherence tomography before and after surgery. We analyzed postoperative changes in these parameters and related factors to preoperative segmentation errors. Results: In glaucoma patients, a significant increase in the average thickness of the pRNFL (p = 0.002) was observed after surgery, while no significant changes were seen in ONH parameters and the average thickness of the mGC-IPL (all p > 0.05). Conversely, the control group showed an increase in some areas of mGC-IPL thickness after surgery (p < 0.05). Multivariate regression analysis indicated that in glaucoma patients, thinner preoperative pRNFL and mGC-IPL thickness were predictors of increased average thickness after surgery (p < 0.001 and p = 0.008, respectively). Conclusions: Cataract significantly impacts the pRNFL and mGC-IPL thickness in glaucoma patients, with less effect on ONH parameters. These findings suggest that ONH parameters can be more reliable for monitoring patients undergoing cataract surgery and assessing glaucoma progression simultaneously.
引用
收藏
页码:442 / 455
页数:14
相关论文
共 25 条
  • [1] EVALUATION OF METHODS FOR AUTOMATED HEMIFIELD ANALYSIS IN PERIMETRY
    ASMAN, P
    HEIJL, A
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (06) : 820 - 826
  • [2] Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography
    Bambo, Maria P.
    Garcia-Martin, Elena
    Otin, Sofia
    Sancho, Eva
    Fuertes, Isabel
    Herrero, Raquel
    Satue, Maria
    Pablo, Luis
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) : 52 - 58
  • [3] Choi Young-Je, 2023, Korean J Ophthalmol, V37, P12, DOI 10.3341/kjo.2022.0097
  • [4] THE LENS OPACITIES CLASSIFICATION SYSTEM-III
    CHYLACK, LT
    WOLFE, JK
    SINGER, DM
    LESKE, MC
    BULLIMORE, MA
    BAILEY, IL
    FRIEND, J
    MCCARTHY, D
    WU, SY
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) : 831 - 836
  • [5] The effect of phacoemulsification cataract surgery on the measurement of retinal nerve fiber layer thickness using optical coherence tomography
    El-Ashry, Mohamed
    Appaswamy, Shivashankar
    Deokule, Sunil
    Pagliarini, Sergio
    [J]. CURRENT EYE RESEARCH, 2006, 31 (05) : 409 - 413
  • [6] OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA
    HEE, MR
    IZATT, JA
    SWANSON, EA
    HUANG, D
    SCHUMAN, JS
    LIN, CP
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) : 325 - 332
  • [7] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [8] Jha Bhaskar, 2017, Oman J Ophthalmol, V10, P91, DOI 10.4103/ojo.OJO_93_2016
  • [9] COMPARISON OF ANALYTIC ALGORITHMS FOR DETECTING GLAUCOMATOUS VISUAL-FIELD LOSS
    KATZ, J
    SOMMER, A
    GAASTERLAND, DE
    ANDERSON, DR
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (12) : 1684 - 1689
  • [10] Detection of incident field loss using the glaucoma hemifield test
    Katz, J
    Quigley, HA
    Sommer, A
    [J]. OPHTHALMOLOGY, 1996, 103 (04) : 657 - 663