Evaluation of a Novel Drilling Approach for Dynamic Navigation-Aided Endodontic Microsurgery: A Surgical Simulation Comparison Study

被引:3
作者
Qin, Li [1 ,2 ]
Chen, Chen [1 ,2 ]
Zhang, Rui [1 ,2 ]
Wang, Zan [1 ,2 ]
Li, Fangzhe [1 ,2 ]
Meng, Liuyan [1 ,2 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, State Key Lab Oral & Maxillofacial Reconstruct & R, Key Lab Oral Biomed,Minist Educ,Hubei Key Lab Stom, Luoyu Road 237, Wuhan 430079, Hubei, Peoples R China
[2] Wuhan Univ, Sch & Hosp Stomatol, Dept Cariol & Endodont, Wuhan, Peoples R China
关键词
Accuracy; dynamic navigation; endodontic microsurgery; safety; time; trephine; ACCURACY; EFFICIENCY; SYSTEM;
D O I
10.1016/j.joen.2024.03.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study investigated the feasibility of a novel drilling approach that integrates a pilot trephine into dynamic navigation (DN) for guided osteotomy and root-end resection (RER) with unimanual operation in endodontic microsurgery. Methods: Two operators with varying levels of DN experience performed guided osteotomy and RER using 2 unimanual drilling methods with DN-aided operation on 3-dimensional printed jaw models. Method 1 (M1) involved drilling with a conventional trephine. Method 2 (M2) involved drilling with a pilot trephine, followed by drilling with a conventional trephine. Accuracy, time, and safety of M1 and M2 were compared. Accuracy measurements included platform deviation (PD), end deviation (ED), angular deviation (AD), resection length deviation (RLD), and resection bevel angle (RBA). Additional parameters included osteotomy and RER time (OT) and bur slippage number (BSN). Statistical analyses were conducted using a 2-sample t-test or Mann-Whitney U test, with the significance level set at .05. Results: The PD, AD, RBA, and BSN in the M2 group were significantly less than in the M1 group (P < .05). For M1, the novice operator (NO) exhibited significantly higher values of PD, ED, OT, and BSN than the experienced operator (EO) (P < .05). For M2, the NO exhibited significantly higher value of ED only (P < .05), and drilling depth .7 mm was significantly associated with a longer OT (P < .05). Conclusion: In this surgical simulation comparison study, the incorporation of a pilot drill improved the accuracy and safety of DN-aided endodontic microsurgery.
引用
收藏
页码:989 / 996
页数:8
相关论文
共 20 条
[11]   Accuracy and the role of experience in dynamic computer guided dental implant surgery: An in-vitro study [J].
Jorba-Garcia, Adria ;
Figueiredo, Rui ;
Gonzalez-Barnadas, Albert ;
Camps-Font, Octavi ;
Valmaseda-Castellon, Eduard .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (01) :E76-E83
[12]   Outcome of nonsurgical retreatment and endodontic microsurgery: a meta-analysis [J].
Kang, Minji ;
Jung, Hoi In ;
Song, Minju ;
Kim, Sue Youn ;
Kim, Hyeon-Cheol ;
Kim, Euiseong .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (03) :569-582
[13]   Modern endodontic surgery concepts and practice: A review [J].
Kim, Syngcuk ;
Kratchman, Samuel .
JOURNAL OF ENDODONTICS, 2006, 32 (07) :601-623
[14]  
Liu S M, 2022, Beijing Da Xue Xue Bao Yi Xue Ban, V54, P146
[15]   Comparison of the Accuracy and Efficiency of a 3-Dimensional Dynamic Navigation System for Osteotomy and Root-end Resection Performed by Novice and Experienced Endodontists [J].
Martinho, Frederico C. ;
Aldahmash, Sara A. ;
Cahill, Thomas Y. ;
Gupta, Swati ;
Dianat, Omid ;
Mostoufi, Behzad ;
Price, Jeffery B. ;
Griffin, Ina ;
Tordik, Patricia A. .
JOURNAL OF ENDODONTICS, 2022, 48 (10) :1327-+
[16]   Removal of failed dental implants revisited: Questions and answers [J].
Solderer, Alex ;
Al-Jazrawi, Adrian ;
Sahrmann, Philipp ;
Jung, Ronald ;
Attin, Thomas ;
Schmidlin, Patrick R. .
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2019, 5 (06) :712-724
[17]  
Sreedevi Pv, 2011, J Conserv Dent, V14, P68, DOI 10.4103/0972-0707.80743
[18]   Accuracy and Efficiency of Endodontic Microsurgery Assisted by Dynamic Navigation Based on Two Different Registration Methods: An In Vitro Study [J].
Wang, Zan ;
Chen, Chen ;
Qin, Li ;
Li, Fangzhe ;
Chen, Yun ;
Meng, Liuyan .
JOURNAL OF ENDODONTICS, 2023, 49 (09) :1199-1206
[19]   Effect of Field of View and Voxel Size on CBCT-Based Accuracy of Dynamic Navigation in Endodontic Microsurgery: An In Vitro Study [J].
Wang, Zan ;
Guo, Xiaolong ;
Chen, Chen ;
Qin, Li ;
Meng, Liuyan .
JOURNAL OF ENDODONTICS, 2023, 49 (08) :1012-1019
[20]   Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Procedure for Endodontic Access Cavities: An In Vitro Study [J].
Zubizarreta-Macho, Alvaro ;
de Pedro Munoz, Ana ;
Riad Deglow, Elena ;
Agustin-Panadero, Ruben ;
Mena Alvarez, Jesus .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (01)