Correlation to predict thermal characteristics of pulsating heat pipes with long evaporator section

被引:0
作者
Sakulchangsatjatai, Phrut [1 ]
Siritan, Methida [1 ]
Wanison, Ramnarong [1 ]
Kammuang-Lue, Niti [1 ]
Terdtoon, Pradit [1 ]
机构
[1] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Heat Pipe & Heat Syst Lab, Chiang Mai 50200, Thailand
关键词
Closed-loop pulsating heat pipe; Extra-long evaporator section; Evacuated glass tube solar water heating; system; Semi-Empirical Correlation; Solar simulator; CLOSED-END; FLOW VISUALIZATION; SOLAR COLLECTOR; WORKING FLUIDS; PERFORMANCE; INSTABILITY; PART;
D O I
10.1016/j.applthermaleng.2024.123868
中图分类号
O414.1 [热力学];
学科分类号
摘要
In terms of employing closed-loop pulsating heat pipes as heat transfer devices in solar water heaters, the evaporator should be extremely long according to the length of the solar collector. However, there is a noticeable shortage of Semi-Empirical Correlations for predicting the thermal performance of extra-long closed-loop pulsating heat pipes utilized for heat absorption within solar collectors. The primary objective of this study was to formulate a Semi-Empirical Correlation specifically designed for predicting the thermal efficiency in extra-long closed-loop pulsating heat pipe configurations. This study extensively examined the thermal efficiency of a comprehensive design of closed-loop pulsating heat pipe samples when implemented in an evacuated-tube solar water heater system strategically designed for individual households. The specified maximum length for the evaporator section of the closed-loop pulsating heat pipes is set at 1.50 m, in contrast to the conventional design, which typically features an evaporator section of approximately 0.15 m. Furthermore, the investigation encompasses a number of sets, varying as one, two, and four. Therefore, a Semi-Empirical Correlation derived from the experimental data concerning seven pertinent non-dimensional parameters is presented, demonstrating a standard deviation percentage of 4.4 %. Among these parameters, the number of sets emerged as the most influential, inducing a maximum percentage change in the heat rate of water of 20.47 %. Moreover, compared with other studies utilizing pulsating heat pipes in solar water heaters, the correlation exhibited a 1.52 % error. These findings suggest that the developed Semi-Empirical Correlation is a valuable tool for predicting the thermal performance of an extra-long closed-loop pulsating heat pipe. It is particularly well suited for estimating the thermal behavior of closed-loop pulsating heat pipes with extended configurations, showcasing its enhanced accuracy and relevance in capturing the distinction of heat transfer in extra-long closed-loop pulsating heat pipe systems.
引用
收藏
页数:13
相关论文
共 44 条
  • [1] [Anonymous], 2006, EN 12975-2
  • [2] A novel dual-diameter closed-loop pulsating heat pipe for a flat plate solar collector
    Aref, Latif
    Fallahzadeh, Rasoul
    Shabanian, Seyed Reza
    Hosseinzadeh, Mojtaba
    [J]. ENERGY, 2021, 230
  • [3] Partial visualization study on flow, startup and heat transfer characteristics of closed-loop pulsating heat pipe with R1336mzz(Z)
    Bao, Kangli
    Liu, Ying
    Yan, Yuhao
    Ye, Gongran
    Han, Xiaohong
    [J]. APPLIED THERMAL ENGINEERING, 2023, 226
  • [4] Closed loop pulsating heat pipes - Part A: parametric experimental investigations
    Charoensawan, P
    Khandekar, S
    Groll, M
    Terdtoon, P
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (16) : 2009 - 2020
  • [5] Thermal performance of horizontal closed-loop oscillating heat pipes
    Charoensawan, Piyanun
    Terdtoon, Pradit
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (5-6) : 460 - 466
  • [6] Thermal performance correlation of horizontal closed-loop oscillating heat pipes
    Charoensawan, Piyanun
    Terdtoon, Pradit
    [J]. 2007 9TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2007, : 906 - +
  • [7] Predicting thermal instability in a closed loop pulsating heat pipe system
    Chen, Ping-Hei
    Lee, Ya-Wei
    Chang, Tien-Li
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1566 - 1576
  • [8] Detailed visualization experiments on the start-up process and stable operation of pulsating heat pipes: Effects of dividing boards
    Cheng, Po -Shen
    Wong, Shwin-Chung
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [9] Thermal performance of rotating closed-loop pulsating heat pipes: Experimental investigation and semi-empirical correlation
    Dehshali, M. Ebrahimi
    Nazari, M. A.
    Shafii, M. B.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 123 : 14 - 26
  • [10] Correlation for Predicting Heat Transfer Characteristics of A Helical Oscillating Heat Pipe (HOHP) at Normal Operating Conditions
    Donmuang, Amorn
    Chompookham, Teerapat
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2021, 10 (02): : 171 - 182