3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING

被引:0
|
作者
Cetin, Tugce [1 ]
Asian, Y. Umut [1 ]
机构
[1] Marmara Univ, Sch Dent, Dept Prosthodont, Istanbul, Turkiye
关键词
IN-VITRO EVALUATION; BIOMECHANICAL BEHAVIOR; FRACTURE-RESISTANCE; LOAD APPLICATION; HYBRID ABUTMENT; INTERFACE; FATIGUE; CROWNS; MICROMOTION; METAL;
D O I
10.11607/ijp.8308
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To analyze the microgap changes between hybrid -abutment crowns made of two materials and three internal taper connection implants with different connection designs before and after thermodynamic loading. Materials and Methods: A total of 30 implants -10 each of Straumann Bone Level Implant -RC (STR); GC AADVA Implant (AAD); and Astra-Tech OsseoSpeed EV (AST) -were included in this laboratory study. Each implant had an internal taper connection, but their designs were slightly different. Five hybrid -abutment crowns were fabricated using a lithium disilicate ceramic (LD), and five were fabricated using polymethylmethacrylate (PMMA) with CAD/CAM technologies for each implant system, providing six sample groups STR-LD, AAD-LD, AST-LD, STR-PMMA, AAD-PMMA, and ASTPMMA. The microgap volume was measured using micro -CT images obtained before and after thermodynamic loading equivalent to 4 months of clinical use. Student ttest, one-way ANOVA, and Tukey test were used for comparisons. Results: The greatest microgap volume increase was recorded (3.405% +/- 1.567%) in the AST-LD group, and the lowest increase (0.45% +/- 0.373%) was in the STR-PMMA group. A statistically significant difference in microgap increase was not detected among PMMA and LD groups: for STR-LD/STR-PMMA (t test: P = .273); for AAD-LD/AAD-PMMA (t test: P = .374); and for AST-LD/AST-PMMA (t test: P = .268). However, the difference in the microgap increase between the different implant systems was statistically significant. Conclusions: The microgap between hybrid -abutment crowns and implants increased after short-term thermodynamic cycling. Hybrid -abutment crowns with different elastic modulus showed similar microgap increase. The geometric shape of the connection influenced the microgap increase. Intl Prosthodont 2024;37:e99 -e111. doi: 10.11607/ijp.8308
引用
收藏
页码:e99 / e111
页数:13
相关论文
共 50 条
  • [31] Evaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection
    Gonzalo, Esther
    Vizoso, Beatriz
    Lopez-Suarez, Carlos
    Diaz, Pedro
    Pelaez, Jesus
    Suarez, Maria J.
    MATERIALS, 2020, 13 (21) : 1 - 12
  • [32] Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study
    Sammour, Sara Reda
    El-Sheikh, Mohamed Maamoun
    El-Gendy, Attiah Aly
    DENTAL MATERIALS, 2019, 35 (11) : E265 - E271
  • [33] The influence of stiffness of implant-abutment connection on load-deflection ratios of a screw-retained stiff cantilever beam. 3-D measurements in vitro
    Cassel, Bjorn
    Lundgren, Dan
    Karlsson, Dan
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (11) : 1251 - 1256
  • [34] Evaluation of Castable and Premachined Metal Base Abutment/Implant Interfaces Before and After Cyclical Load
    De Mori, Renato
    Ribeiro, Cyntia Ferreira
    da Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    IMPLANT DENTISTRY, 2014, 23 (02) : 212 - 217
  • [35] Evaluation of Implant Body Diameter, Platform Diameter, and the Use of a Transepithelial Component on Implant-Abutment Connection Microgap: An In Vitro Study with In Situ Hard X-Ray Radiography
    Armentia, Mikel
    Abasolo, Mikel
    Coria, Ibai
    Zabler, Simon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (03) : 489 - 495
  • [36] Abutment Rotational Freedom Evaluation of External Hexagon Single-Implant Restorations after Mechanical Cycling
    Junqueira, Marcela C.
    Silva, Thales Eduardo P.
    Ribeiro, Ricardo F.
    Faria, Adriana Claudia L.
    Macedo, Ana Paula
    de Almeida, Rossana P.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (06) : 927 - 933
  • [37] The Role of Implant/Abutment System on Torque Maintenance of Retention Screws and Vertical Misfit of Implant-Supported Crowns Before and After Mechanical Cycling
    Pala Jorge, Juliana Ribeiro
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 415 - 422
  • [38] Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments
    Diaz, Pedro
    Vizoso, Beatriz
    Lopez-Suarez, Carlos
    Gonzalo, Esther
    Mosaddad, Seyed Ali
    Suarez, Maria J.
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (01)
  • [39] A Comparative Evaluation of Stress Distribution at the Implant Abutment Interface between Platforms Switched Morse Taper and Pseudo Platform Switched Internal Hex Connection Implant - A 3D Finite Element Analysis
    Borse, Anuradha
    Tabassum, Rubina
    Shetty, Omkar
    ADVANCES IN HUMAN BIOLOGY, 2014, 4 (02) : 22 - 31
  • [40] Cone Beam Computed Tomographic Evaluation of Implants with Platform-Switched Morse Taper Connection with the Implant-Abutment Interface at Different Levels in Relation to the Alveolar Crest
    Koutouzis, Theofilos
    Neiva, Rodrigo
    Nair, Madhu
    Nonhoff, Joerg
    Lundgren, Tord
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (05) : 1157 - 1163