The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation

被引:1
作者
Kerrebijn, Isabel [1 ]
Atwi, Sarah [1 ]
Elfarnawany, Mai [1 ]
Eibl, Andrew M. [1 ,2 ]
Eibl, Joseph K. [1 ,2 ,3 ]
Taylor, Jenna L. [4 ,5 ]
Kim, Chul-Ho [4 ]
Johnson, Bruce D. [4 ]
Kenny, Jon-Emile S. [1 ,2 ]
机构
[1] Floson Med, 325 W Front St, Toronto, ON M5V 2Y1, Canada
[2] Hlth Sci North Res Inst, Sudbury, ON, Canada
[3] Northern Ontario Sch Med Univ, Sudbury, ON, Canada
[4] Mayo Clin, Human Integrat & Environm Physiol Lab, Dept Cardiovasc Dis, Rochester, MN USA
[5] Univ Queensland, Sch Human Movement & Nutr Sci, Physiol & Ultrasound Lab Sci & Exercise, Brisbane, Australia
关键词
carotid artery; corrected flow time; Doppler ultrasound; functional hemodynamic monitoring; wearable technology; velocity time integral; FLUID RESPONSIVENESS; FLOW;
D O I
10.4266/acc.2023.01095
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively -averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated -measures linear correlation [R rm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively -averaged cardiac cycles. For ccFT, beyond four consecutively -averaged cardiac cycles the correlation coefficient remained strong (i.e., R rm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, R rm remained stable around 25 consecutively -averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively -averaged cardiac cycles.
引用
收藏
页数:224
相关论文
共 25 条
[1]   CHANGE IN CAROTID BLOOD FLOW AND CAROTID CORRECTED FLOW TIME ASSESSED BY NOVICE SONOLOGISTS FAILS TO DETERMINE FLUID RESPONSIVENESS IN SPONTANEOUSLY BREATHING INTENSIVE CARE UNIT PATIENTS [J].
Abbasi, Adeel ;
Azab, Nader ;
Nayeemuddin, Mohammed ;
Schick, Alexandra ;
Lopardo, Thomas ;
Phillips, Gary S. ;
Merchant, Roland C. ;
Levy, Mitchell M. ;
Blaivas, Michael ;
Corl, Keith A. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (10) :2659-2666
[2]   Ultrasound Assessment of the Change in Carotid Corrected Flow Time in Fluid Responsiveness in Undifferentiated Shock [J].
Barjaktarevic, Igor ;
Toppen, William E. ;
Hu, Scott ;
Montoya, Elizabeth Aquije ;
Ong, Stephanie ;
Buhr, Russell ;
David, Ian J. ;
Wang, Tisha ;
Rezayat, Talayeh ;
Chang, Steven Y. ;
Elashoff, David ;
Markovic, Daniela ;
Berlin, David ;
Cannesson, Maxime .
CRITICAL CARE MEDICINE, 2018, 46 (11) :E1040-E1046
[3]   Carotid Ultrasound to Predict Fluid Responsiveness A Systematic Review [J].
Beier, Lance ;
Davis, Joshua ;
Esener, Dasia ;
Grant, Charles ;
Fields, J. Matthew .
JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (10) :1965-1976
[4]   Observational study in healthy volunteers to define interobserver reliability of ultrasound haemodynamic monitoring techniques performed by trainee doctors [J].
Bussmann, Benjamin M. ;
Sharma, Shrey ;
Mcgregor, David ;
Hulme, William ;
Harris, Tim .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2019, 26 (03) :217-223
[5]   Passive leg raising test using the carotid flow velocity-time integral to predict fluid responsiveness [J].
Cheong, Issac ;
Otero Castro, Victoria ;
Sosa, Fernando Ariel ;
Tort Oribe, Barbara ;
Fruechtenicht, Maria Florencia ;
Tamagnone, Francisco Marcelo ;
Merlo, Pablo Martin .
JOURNAL OF ULTRASOUND, 2024, 27 (01) :97-104
[6]   Carotid flow as a surrogate of the left ventricular stroke volume [J].
Cheong, Issac ;
Castro, Victoria Otero ;
Sosa, Fernando Ariel ;
Oribe, Barbara Tort ;
Merlo, Pablo Martin ;
Tamagnone, Francisco Marcelo .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (02) :661-667
[7]   Fluid Response Evaluation in Sepsis Hypotension and Shock A Randomized Clinical Trial [J].
Douglas, Ivor S. ;
Alapat, Philip M. ;
Corl, Keith A. ;
Exline, Matthew C. ;
Forni, Lui G. ;
Holder, Andre L. ;
Kaufman, David A. ;
Khan, Akram ;
Levy, Mitchell M. ;
Martin, Gregory S. ;
Sahatjian, Jennifer A. ;
Seeley, Eric ;
Self, Wesley H. ;
Weingarten, Jeremy A. ;
Williams, Mark ;
Hansell, Douglas M. .
CHEST, 2020, 158 (04) :1431-1445
[8]   Characteristics of resuscitation, and association between use of dynamic tests of fluid responsiveness and outcomes in septic patients: results of a multicenter prospective cohort study in Argentina [J].
Dubin, Arnaldo ;
Loudet, Cecilia ;
Kanoore Edul, Vanina S. ;
Osatnik, Javier ;
Rios, Fernando ;
Vasquez, Daniela ;
Pozo, Mario ;
Lattanzio, Bernardo ;
Palizas, Fernando ;
Klein, Francisco ;
Piezny, Damian ;
Rubatto Birri, Paolo N. ;
Tuhay, Graciela ;
Garcia, Analia ;
Santamaria, Analia ;
Zakalik, Graciela ;
Gonzalez, Cecilia ;
Estenssoro, Elisa .
ANNALS OF INTENSIVE CARE, 2020, 10 (01)
[9]   Electrical Cardiometry Versus Carotid Doppler in Assessment of Fluid Responsiveness in Critically III Septic Patients [J].
Effat, Hassan ;
Hamed, Khaled ;
Hamed, Gamal ;
Mostafa, Rania ;
El Hadidy, Samir .
EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 8 (04) :96-113
[10]   Ability of Carotid Corrected Flow Time to Predict Fluid Responsiveness in Patients Mechanically Ventilated Using Low Tidal Volume after Surgery [J].
Jung, Seungho ;
Kim, Jeongmin ;
Na, Sungwon ;
Nam, Won Seok ;
Kim, Do-Hyeong .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (12)