An experimental study on the defrosting performances of an ASHP having a novel dual-fan outdoor coil under different levels of frosting evenness along airflow direction

被引:1
作者
Bai, Xiaoxia [1 ]
Ge, Zhong [1 ]
Deng, Shiming [2 ]
Qu, Minglu [3 ]
Sang, Xuejing [3 ]
Zhang, Long [4 ]
机构
[1] Yunnan Univ, Sch Architecture & Urban Planning, Kunming 650504, Peoples R China
[2] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, 516 Jungong Rd, Shanghai, Peoples R China
[4] Beijing Inst Technol, Sch Mech Engn, Dept Energy & Power Engn, Beijing, Peoples R China
关键词
Air source heat pump; Novel dual -fan outdoor coil; Even frosting characteristics; Different levels of frosting evenness; Defrosting performances; SOURCE HEAT-PUMP; LIQUID DESICCANT DEHUMIDIFICATION; EXCHANGER; UNIT; OPTIMIZATION; OPERATION; FIN;
D O I
10.1016/j.enbuild.2024.114464
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Uneven frosting along the airflow direction is a common phenomenon that can accelerate deteriorating the heating efficiency of ASHP units under frosting conditions. To effectively alleviate this uneven frosting phenomenon, an experimental ASHP unit having a novel dual-fan outdoor coil (ASHP / DFOC) was developed in a previous experimental study. The ability of the DFOC on achieving even frosting along the airflow direction, and the operating performances of the experimental ASHP/DFOC unit at different levels of even frosting evenness were experimentally and numerically investigated. However, the defrosting performances of the experimental ASHP/DFOC unit at different levels of frosting evenness remain to be evaluated, which was nonetheless essential for developing an on-demand defrosting initiation method for achieving higher defrosting efficiency. Therefore, the defrosting performances of the experimental ASHP/DFOC unit at different levels of even frosting were experimentally investigated in this paper. Five experimental cases with different levels of even frosting were designated, and the defrosting performances of the experimental ASHP/DFOC unit, including the defrosting time duration at different defrosting stages and the energy consumption during defrosting, were analyzed in great detail. The results demonstrated that during a single frosting-defrosting operating cycle, the defrosting always proceeded from one side to the other along the refrigerant flow direction. The evener the frosting level, the longer the frosting and defrosting duration, and the lower the defrosting efficiency. However, during multiple frosting-defrosting cycles, the evener the frosting level, the higher the comprehensive heating performances of the experimental ASHP/DFOC unit. The results from this study have provided a valuable basis for developing a more accurate defrosting initiation method with a higher defrosting efficiency for ASHP/DFOC units.
引用
收藏
页数:10
相关论文
共 33 条
  • [1] An optimal control strategy for ASHP units with a novel dual-fan outdoor coil for evener frosting along airflow direction based on GRNN modelling
    Bai, Xiaoxia
    Liu, Shengnan
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    [J]. ENERGY AND BUILDINGS, 2023, 292
  • [2] A modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit
    Bai, Xiaoxia
    Liu, Shengnan
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    [J]. APPLIED THERMAL ENGINEERING, 2023, 222
  • [3] An experimental study on achieving even-frosting for an air source heat pump using a novel dual-fan outdoor coil
    Bai, Xiaoxia
    Liu, Shengnan
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    [J]. ENERGY AND BUILDINGS, 2022, 255
  • [4] Air Source Heat Pumps field studies: A systematic literature review
    Carroll, P.
    Chesser, M.
    Lyons, P.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 134
  • [5] An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump
    Dong, Jiankai
    Deng, Shiming
    Jiang, Yiqiang
    Xia, Liang
    Yao, Yang
    [J]. APPLIED THERMAL ENGINEERING, 2012, 37 : 380 - 387
  • [6] An experimental study on the frosting characteristic and performance of a micro-channel evaporator in an air source heat pump unit
    Hu, Wenju
    Fan, Jin
    Song, Mengjie
    Jia, Peng
    Gao, Yan
    [J]. ENERGY AND BUILDINGS, 2020, 224 (224)
  • [7] An experimental study on the operating performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps
    Hu Wenju
    Jiang Yiqiang
    Qu Minglu
    Ni Long
    Yao Yang
    Deng Shiming
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (2-3) : 363 - 369
  • [8] A novel defrosting control method based on the degree of refrigerant superheat for air source heat pumps
    Jiang, Yiqiang
    Dong, Jiankai
    Qu, Minglu
    Deng, Shiming
    Yao, Yang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08): : 2278 - 2288
  • [9] Local frosting behavior of a plated-fin and tube heat exchanger according to the refrigerant flow direction and surface treatment
    Kim, Kyoungmin
    Kim, Dong Rip
    Lee, Kwan-Soo
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 : 751 - 758
  • [10] Frosting and defrosting characteristics of a fin according to surface contact angle
    Kim, Kyoungmin
    Lee, Kwan-Soo
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (13-14) : 2758 - 2764