KINEMATIC RESPONSES AND SEGMENTAL STIFFNESS OF NORMAL AND DEGENERATIVE L4/L5 MOTION SEGMENTS: FINITE ELEMENT STUDY

被引:1
作者
Geng, Yunhui [1 ,2 ]
Wang, Taoxi [2 ]
Xu, Chonglun [4 ]
Bian, Huwei [3 ]
Shen, Xing [2 ]
Teo, Ee chon [4 ]
Jiang, Tao [3 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, State Key Lab Mech & Control Aerosp Struct, Nanjing, Peoples R China
[3] Nanjing Univ Chinese Med, Changzhou Hosp Tradit Chinese Med, Changzhou, Peoples R China
[4] Ningbo Univ, Fac Sports Sci, Ningbo, Peoples R China
关键词
Finite element; L4-L5; lumbar; degenerated; intervertebral disc; stress redistribution; greyscale values; segmental stiffness; MECHANICAL-PROPERTIES; INTERVERTEBRAL JOINTS; FATIGUE BEHAVIOR; SPINE; DISC; LIGAMENTS;
D O I
10.1142/S0219519424500180
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, finite element (FE) models of an anatomical normal and a degenerated disc of L4-L5 motion segment, developed using different methodologies of volume mesh constructions, and ways of defining the spinal components' material properties, were exercised and analyzed. The geometrics details were obtained using digitizing technique and segmentation of computed tomography (CT) scans; with material and structural properties of the spinal components defined based on the literature and greyscale values of CT images for the normal and degenerated L4-L5 motion segments, respectively. The predicted kinematic responses under five different physiological loadings in three anatomical reference planes for both models together with published data were analyzed. The predicted results correlated well within the range and in similar trends with published experimental results. The overall predicted responses showed different volume mesh constructions and the representation of spinal components' material properties were accurate enough to predict the kinematic responses, although experimental results exhibit considerable divergence due to different experimental techniques. Both models exhibited different rotational and translation segmental stiffness in each corresponding loading configuration. The normal L4-L5 segment exhibited greatest axial torsional stiffness, and least extensional stiffness. The degenerated L4-L5 segment was least flexible (greatest stiffness) in extension and most flexible (least stiffness) in flexion. For compression, the axial stiffness of segment of normal segment was about 10% larger than that of the degenerated segment. The en-bloc efforts of all spinal components have contributed to the different nonlinear kinematic characteristics and segmental stiffness of these different L4-L5 motion segments.
引用
收藏
页数:15
相关论文
共 27 条
[1]   EFFECTS OF FLUID INJECTION ON MECHANICAL-PROPERTIES OF INTERVERTEBRAL DISKS [J].
ANDERSSON, GBJ ;
SCHULTZ, AB .
JOURNAL OF BIOMECHANICS, 1979, 12 (06) :453-458
[2]  
BRINCKMANN P, 1988, CLIN BIOMECH, V3, pS1
[3]   SOME MECHANICAL TESTS ON THE LUMBOSACRAL SPINE WITH PARTICULAR REFERENCE TO THE INTERVERTEBRAL DISCS - A PRELIMINARY REPORT [J].
BROWN, T ;
HANSEN, RJ ;
YORRA, AJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1957, 39 (05) :1135-1164
[4]   Using finite element analysis to determine effects of the motion loading method on facet joint forces after cervical disc degeneration [J].
Cai, Xin-Yi ;
Sang, Dacheng ;
Yuchi, Chen-Xi ;
Cui, Wei ;
Zhang, Chunqiu ;
Du, Cheng-Fei ;
Liu, Baoge .
COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 116
[5]   BIOMECHANICAL PROPERTIES OF SPINAL LIGAMENTS AND A HISTOLOGICAL STUDY OF THE SUPRASPINAL LIGAMENT IN TRACTION [J].
CHAZAL, J ;
TANGUY, A ;
BOURGES, M ;
GAUREL, G ;
ESCANDE, G ;
GUILLOT, M ;
VANNEUVILLE, G .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :167-176
[6]   Biomechanical analysis of a new lumbar interspinous device with optimized topology [J].
Chen, Chen-Sheng ;
Shih, Shih-Liang .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (08) :1333-1341
[7]  
Chen CS, 2001, MED ENG PHYS, V23, P483
[8]   Hip strategy alterations in patients with history of low disc herniation and non-specific low back pain measured by surface electromyography and balance platform [J].
Ciesielska, Jagoda ;
Lisinski, Przemyslaw ;
Bandosz, Agata ;
Huber, Juliusz ;
Kulczyk, Aleksandra ;
Lipiec, Joanna .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2015, 17 (03) :103-108
[9]   Biomechanical investigation of thoracolumbar spine in different postures during ejection using a combined finite element and multi-body approach [J].
Du, Chengfei ;
Mo, Zhongjun ;
Tian, Shan ;
Wang, Lizhen ;
Fan, Jie ;
Liu, Songyang ;
Fan, Yubo .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (11) :1121-1131
[10]   INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS [J].
GOEL, VK ;
MONROE, BT ;
GILBERTSON, LG ;
BRINCKMANN, P ;
NAT, R .
SPINE, 1995, 20 (06) :689-698