Comparison of two objective methods for measuring postoperative toric intraocular lens orientation under the natural pupil

被引:0
|
作者
Jiang, Yuanfeng [1 ]
Gao, Yichen
Yang, Jun
Chen, Xiteng
Zhao, Fangyu
Li, Meisa
Lin, Song
Bu, Shaochong
Tian, Fang
机构
[1] Tianjin Key Lab Retinal Funct & Dis, Tianjin, Peoples R China
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2023年 / 49卷 / 12期
关键词
ROTATIONAL STABILITY; ALIGNMENT;
D O I
10.1097/j.jcrs.0000000000001295
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate and compare the accuracy of iTrace and CASIA2 in measuring the postoperative orientation of toric intraocular lens (IOL) without mydriasis. Setting: Tianjin Medical University Eye Hospital, Tianjin, China. Design: Prospective cohort study. Methods: Patients with SN6AT toric IOLs implanted after cataract surgery were enrolled. 1 month after surgery, the toric IOL orientation were measured by iTrace and CASIA2 in non-mydriatic, semi-dark conditions. Then, the toric axis was directly reviewed using the slit-lamp under full mydriasis. Axis measurement differences between each of the 2 devices and the slit-lamp, described as their relative differences (RDs), were calculated and compared. The percentage of RDs within 5 degrees, within 10 degrees and greater than 30 degrees were analyzed. Results: 77 eyes of 70 patients were included. Generally, the mean toric axis measurement RDs of CASIA2 and iTrace were 9.24 +/- 10.53 degrees and 13.89 +/- 15.47 degrees respectively (P = .04). For CASIA2 (72 eyes), 54.17% (39), 72.22% (52), and 4.17% (3) of eyes had RDs within 5 degrees, within 10 degrees and greater than 30 degrees, compared with 40.00% (28), 61.43% (43) and 12.86% (9) for iTrace (70 eyes). The 95% limits of agreements of CASIA2 with slit-lamp was narrower than that of iTrace with slit-lamp. The median RD of CASIA2 was significantly smaller in eyes with pupil >= 4 mm under dark condition compared with eyes with pupil <4 mm (P = .03). Conclusions: CASIA2 demonstrates greater precision in measuring toric IOL orientation under non-mydriatic conditions compared with iTrace. Moreover, the accuracy of CASIA2 is enhanced in cases of pupil >4 mm.
引用
收藏
页码:1223 / 1228
页数:6
相关论文
共 27 条
  • [1] Comparison of the Clinical Outcomes of Two Types of Toric Intraocular Lens
    Yang, Soon Won
    Lee, Jae Hoon
    Lim, Sung A.
    Chung, So Hyang
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (02): : 200 - 207
  • [2] A COMPARISON OF 3 METHODS OF MEASUREMENT OF TORIC SOFT LENS ORIENTATION
    FINK, BA
    TOMLINSON, A
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1982, 59 (07): : 611 - 614
  • [3] Comparison of two digital alignment systems for toric intraocular lens implantation
    Zeilinger, Johannes
    Schlatter, Andreas
    Ruiss, Manuel
    Bayer, Natascha
    Kronschlaeger, Martin
    Findl, Oliver
    BMJ OPEN OPHTHALMOLOGY, 2024, 9 (01):
  • [4] Comparison of Axis Determination With Different Toric Intraocular Lens Power Calculation Methods
    Roeggla, Veronika
    Schartmueller, Daniel
    Schwarzenbacher, Luca
    Al Chbib, Rima
    Leydolt, Christina
    Menapace, Rupert
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (09) : 642 - 647
  • [5] Comparison of two methods for measuring orientation
    Geraets, WGM
    BONE, 1998, 23 (04) : 383 - 388
  • [6] Comparison of clinical outcomes among 3 marking methods for toric intraocular lens implantation
    Hideyuki Onishi
    Hidemasa Torii
    Kazuhiro Watanabe
    Kazuo Tsubota
    Kazuno Negishi
    Japanese Journal of Ophthalmology, 2016, 60 : 142 - 149
  • [7] Comparison of clinical outcomes among 3 marking methods for toric intraocular lens implantation
    Onishi, Hideyuki
    Torii, Hidemasa
    Watanabe, Kazuhiro
    Tsubota, Kazuo
    Negishi, Kazuno
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (03) : 142 - 149
  • [8] Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker
    Javed Hussain Farooqui
    Archana Koul
    Ranjan Dutta
    Noshir Minoo Shroff
    International Journal of Ophthalmology, 2016, (05) : 703 - 706
  • [9] Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker
    Farooqui, Javed Hussian
    Koul, Archana
    Dutta, Ranjan
    Shroff, Noshir Minoo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (05) : 703 - 706
  • [10] Predictability of Residual Postoperative Astigmatism After Implantation of a Toric Intraocular Lens Using Two Different Calculators
    Pantanelli, Seth M.
    Kansara, Neal
    Smits, Gerard
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3627 - 3634