Thermophysiological responses and thermal comfort of occupants in indoor spaces under different speaking and non-speaking conditions

被引:2
|
作者
Zhang, Xuange [1 ]
Lee, Minhyun [2 ]
Cui, Xue [1 ]
Huang, Lijie [1 ]
Zhang, Ruixiaoxiao [3 ]
Uddin, Mohammad Nyme [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Hung Hom, Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Res Inst Smart Energy RISE, Dept Bldg & Real Estate, Kowloon, Hong Kong, Peoples R China
[3] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Kowloon, Hong Kong, Peoples R China
关键词
Thermal comfort; Thermophysiological parameters; Speaking activities; Experimental study; Occupant response; TEMPERATURE; SENSATION; SYSTEMS; PMV;
D O I
10.1016/j.buildenv.2024.111682
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As speaking is one of the fundamental behaviours in human activities, understanding the thermal comfort of occupants during speaking is crucial to providing a satisfactory environment. To further strengthen this understanding and identify how occupant thermal responses change during speaking activities, this study performs an experiment to examine the thermophysiological parameters and thermal comfort of occupants across three different speaking and non -speaking conditions: (1) silent (i.e., non -speaking); (2) speech (i.e., continuous speaking); and (3) conversation (i.e., intermittent speaking). During the experiment, thermophysiological parameters, including skin temperature, electrodermal activity, and heart rate, were collected using smart wristbands from 30 subjects at three different temperature settings to represent three distinct thermal environmental conditions: (1) Cold: 20 degrees C; (2) Neutral: 24 degrees C; and (3) Hot: 28 degrees C. Subjects were also required to report their thermal comfort perceptions in terms of thermal sensation votes, thermal preference votes, and thermal satisfaction votes. Repeated measures ANOVA test and Friedman test were used to analyse the thermophysiological parameters and thermal comfort perceptions. The null hypothesis, which suggests no significant differences in thermal responses and comfort across the three speaking conditions, will be rejected at a significance level of 0.05 (two -tail). The results revealed significant differences in all three thermophysiological parameters between speaking conditions at all temperature settings, while the thermal comfort perception did not consistently show statistically significant differences between speaking conditions. The findings contribute to our understanding of the relationship between communication and thermal responses, highlighting the importance of contextual factors in designing comfortable environments for speaking -related activities.
引用
收藏
页数:13
相关论文
共 38 条
  • [21] Assessment of thermal comfort of frail people in a sitting posture under non-uniform conditions using a thermal manikin
    El Akili, Zoubayre
    Bouzidi, Youcef
    Merabtine, Abdelatif
    Polidori, Guillaume
    Kauffmann, Julien
    BUILDING AND ENVIRONMENT, 2022, 221
  • [22] Thermal comfort in naturally ventilated spaces and under indirect evaporative passive cooling conditions in hot-humid climate
    Bravo, Gaudy
    Gonzalez, Eduardo
    ENERGY AND BUILDINGS, 2013, 63 : 79 - 86
  • [23] Dimensionless correlations of indoor thermal stratification in a non-enclosed large-space building under heating and cooling conditions
    Liu, Xiaochen
    Liu, Xiaohua
    Zhang, Tao
    BUILDING AND ENVIRONMENT, 2024, 254
  • [24] Study of indoor local thermal comfort for impinging jet ventilation combined with ductless personalized ventilation under different cooling loads
    Duan, Tao
    Ye, Xiao
    Du, Peng
    Qi, Hechuang
    Kang, Yanming
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2024, 265
  • [25] An innovative PCM system for thermal comfort improvement and energy demand reduction in building under different climate conditions
    Ahangari, Mohamad
    Maerefat, Mehdi
    SUSTAINABLE CITIES AND SOCIETY, 2019, 44 : 120 - 129
  • [26] Measurement-Based Assessment of Energy Performance and Thermal Comfort in Households Under Non-Controllable Conditions
    Stavrakakis, George M.
    Bakirtzis, Dimitris
    Tziritas, Dimitrios
    Zervas, Panagiotis L.
    Fotakis, Emmanuel
    Yfanti, Sofia
    Savvakis, Nikolaos
    Katsaprakakis, Dimitris A.
    ENERGIES, 2025, 18 (05)
  • [27] Experimental evaluation of ECG signal denoising methods based on HRV indices and their application in indoor thermal comfort study under different temperatures
    Ren, Jianlin
    Zhang, Ran
    Cao, Xiaodong
    Kong, Xiangfei
    ENERGY AND BUILDINGS, 2024, 303
  • [28] Effects of return air vent height on energy consumption, thermal comfort conditions and indoor air quality in an under floor air distribution system
    Heidarinejad, Ghassem
    Fathollahzadeh, Mohammad Hassan
    Pasdarshahri, Hadi
    ENERGY AND BUILDINGS, 2015, 97 : 155 - 161
  • [29] Experimental Study on Occupant's Thermal Responses under the Non-uniform Conditions in Vehicle Cabin during the Heating Period
    Zhang Wencan
    Chen Jiqing
    Lan Fengchong
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2014, 27 (02) : 331 - 339
  • [30] Non-adaptive strategies explain variation in rate of development under different thermal conditions
    Folguera, Guillermo
    Catalan, Tamara P.
    Bozinovic, Francisco
    EVOLUTIONARY ECOLOGY RESEARCH, 2009, 11 (05) : 817 - 825