External fixator as a safe method in the treatment of distal tibial fractures in children

被引:0
|
作者
Wen, Yuwei [1 ]
Zhu, Danjiang [1 ]
Wang, Qiang [1 ]
Song, Baojian [1 ]
Feng, Wei [1 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Orthopaed, 56,Nalishi Rd, Beijing 100045, Peoples R China
来源
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B | 2024年 / 33卷 / 03期
基金
国家重点研发计划;
关键词
children; distal tibial fracture; external fixation; metaphyseal diaphyseal junction; PEDIATRIC FEMUR FRACTURES; TITANIUM ELASTIC NAILS; CLASSIFICATION; COMPLICATIONS; PLATE; WIRE;
D O I
10.1097/BPB.0000000000001088
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective The objective of this study is to evaluate the functional and radiological results of external fixator application in the treatment of distal tibial metaphyseal diaphyseal junction (MDJ) fractures in children and to analyze differences between stable and unstable fractures. Methods Medical records of children with distal tibial MDJ fracture confirmed by imaging from January 2015 to November 2021 were retrospectively analyzed. Patients were divided into stable and unstable groups and parameters, including clinical and imaging data and Tornetta ankle score were compared. Results Twenty-five children, comprising 13 with stable and 12 with unstable fractures, were included in our study. The mean age was 7 years (range, 2-13.1 years), and there were 17 males and 8 females. All children had closed reduction, and the basic clinical data of the two groups were comparable. Stable fractures showed shorter intraoperative fluoroscopy, operation, and fracture healing times than unstable fractures. No significant difference in Tornetta ankle score was observed. Twenty-two patients had excellent ankle score, and three had a good ankle score, for a combined incidence of 100%. Two patients in the stable fracture group and one in the unstable fracture group developed a pin site infection, and one patient with unstable fracture showed a length discrepancy (discrepancy<1 cm). Conclusion External fixator is safe and effective for the treatment of distal tibial MDJ fractures, whether the fracture is stable or not. It has the advantages of minimally invasive, excellent ankle function score, few major complications, needless auxiliary cast fixation, and early functional exercise and weight bearing. Level of evidence Level IV.
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [1] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Zhou, Yu
    Wang, Yanbiao
    Liu, Lifeng
    Zhou, Zhenyu
    Cao, Xuecheng
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2227 - 2237
  • [2] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Yu Zhou
    Yanbiao Wang
    Lifeng Liu
    Zhenyu Zhou
    Xuecheng Cao
    International Orthopaedics, 2015, 39 : 2227 - 2237
  • [3] HUGHES EXTERNAL FIXATOR IN TREATMENT OF TIBIAL FRACTURES
    COURTBROWN, CM
    HUGHES, SPF
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1985, 78 (10) : 830 - 837
  • [4] Treatment of distal metaphyseal tibia fractures using an external fixator in children
    Dai, Jin
    Wang, Xiaodong
    Zhang, Fuyong
    Zhu, Lunging
    Zhen, Yunfang
    MEDICINE, 2019, 98 (36)
  • [5] Treatment of distal radius fractures with the external fixator
    Scholz, A. O.
    Schoepp, C.
    Boehm, H-J
    Kortmann, H-R
    TRAUMA UND BERUFSKRANKHEIT, 2007, 9 (01) : 19 - 23
  • [6] Management of feline distal tibial fractures using a hybrid external skeletal fixator
    Witte, P. G.
    Bush, M. A.
    Scott, H. W.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2014, 55 (11) : 571 - 578
  • [7] Management of Nonunion of Distal Tibial Periarticular Fractures Using Ilizarov External Fixator
    Zayda, Ahmed
    Badr, Ismail Tawfeek
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2024, 23 (01): : 12 - 20
  • [8] Treatment of distal tibial fractures with the Ilizarov external fixator - a prospective observational study in 39 consecutive patients
    Ramos, Telmo
    Karlsson, Jon
    Eriksson, Bengt I.
    Nistor, Lars
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [9] Treatment of distal tibial fractures with the Ilizarov external fixator - a prospective observational study in 39 consecutive patients
    Telmo Ramos
    Jón Karlsson
    Bengt I Eriksson
    Lars Nistor
    BMC Musculoskeletal Disorders, 14
  • [10] High-energy open tibial fractures in children TREATMENT WITH A PROGRAMMABLE CIRCULAR EXTERNAL FIXATOR
    Monsell, F. P.
    Howells, N. R.
    Lawniczak, D.
    Jeffcote, B.
    Mitchell, S. R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 989 - 993