Assessment of Biological Damage Induced during Multidetector Computed Tomography (MDCT) Examination

被引:0
作者
Laad, Amarja Pandurang [1 ]
Gnanasekaran, Tamizh Selvan [2 ]
Shetty, Shashi Kumar [1 ]
Vidyan, Savin Kotekar [1 ]
Chodankar, Sayali Satish [1 ]
Nalilu, Suchetha Kumari [3 ]
Radhakrishna, Vishakh [2 ]
机构
[1] Nitte, KS Hegde Med Acad, Dept Med Imaging Technol, Mangalore, India
[2] Nitte, KS Hegde Med Acad, Cent Res Lab, Mangalore, India
[3] Nitte, KS Hegde Med Acad, Dept Biochem, Mangalore, India
关键词
Multidetector computed tomography; Computed tomography; CBMN assay; Iodinated contrast; IODINATED CONTRAST AGENTS; DOUBLE-STRAND BREAKS; RADIATION-DAMAGE; X-RAYS; CT; LYMPHOCYTES;
D O I
10.1007/s12013-024-01345-2
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Computed tomography (CT) is known for its non-invasiveness, fast procedure, and also for providing detailed diagnostic information to physicians. It also utilises low-dose-rate ionising radiation (X-rays) as a source for imaging. Multidetector computed tomography (MDCT) is an advanced system that uses iodinated contrast media for more accurate diagnostic results. Studies suggest using these contrasts will lead to greater radiation adsorption with significant DNA damage. No studies have been taken comparing the physical dose with the biological effect. The present study sheds light on the same by assessing the biological effect of CT with and without contrast intervention. The present study is timebound; thus, 21 participants attending for CT thorax and abdomen with no history of any cancer were included. The same participants underwent both pre-contrast and post-contrast studies. The blood sample was taken before the procedure and used as a control. Physical parameters like DLP and CTDI obtained from the instrument were compared with the MN frequency obtained (CBMN Assay). The study showed a significant increase (p-value < 0.05) in the Physical and MN frequency in the Post-Contrast group compared to the pre-contrast group. Although a positive correlation was observed between pre and post-contrast groups, the results were not found to be statistically significant (p-value < 0.05). The study confirms increased physical dose and MN frequency upon contrast intervention. This study recommends the judicial use of MDCT in disease diagnostics.
引用
收藏
页码:2347 / 2353
页数:7
相关论文
共 23 条
[11]   Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography [J].
Kuefner, M. A. ;
Grudzenski, S. ;
Hamann, J. ;
Achenbach, S. ;
Lell, Michael ;
Anders, K. ;
Schwab, S. A. ;
Haeberle, L. ;
Loebrich, M. ;
Uder, M. .
EUROPEAN RADIOLOGY, 2010, 20 (12) :2917-2924
[12]   Targeted Expression of Catalase to Mitochondria Prevents Age-Associated Reductions in Mitochondrial Function and Insulin Resistance [J].
Lee, Hui-Young ;
Choi, Cheol Soo ;
Birkenfeld, Andreas L. ;
Alves, Tiago C. ;
Jornayvaz, Francois R. ;
Jurczak, Michael J. ;
Zhang, Dongyan ;
Woo, Dong Kyun ;
Shade, Gerald S. ;
Ladiges, Warren ;
Rabinovitch, Peter S. ;
Santos, Janine H. ;
Petersen, Kitt F. ;
Samuel, Varman T. ;
Shulman, Gerald I. .
CELL METABOLISM, 2010, 12 (06) :668-674
[13]   CT Dose Index and Patient Dose: They Are Not the Same Thing [J].
McCollough, Cynthia H. ;
Leng, Shuai ;
Yu, Lifeng ;
Cody, Dianna D. ;
Boone, John M. ;
McNitt-Gray, Michael F. .
RADIOLOGY, 2011, 259 (02) :311-316
[14]   DNA damage by X-rays and their impact on replication processes [J].
Parplys, Ann Christin ;
Petermann, Eva ;
Petersen, Cordula ;
Dikomey, Ekkehard ;
Borgmann, Kerstin .
RADIOTHERAPY AND ONCOLOGY, 2012, 102 (03) :466-471
[15]   Intravenous Iodinated Contrast Agents Amplify DNA Radiation Damage at CT [J].
Piechowiak, Eike I. ;
Peter, Jan-Friedrich W. ;
Kleb, Beate ;
Klose, Klaus J. ;
Heverhagen, Johannes T. .
RADIOLOGY, 2015, 275 (03) :692-697
[16]   CT Dose Reduction Applications: Available Tools on the Latest Generation of CT Scanners [J].
Raman, Siva P. ;
Johnson, Pamela T. ;
Deshmukh, Swati ;
Mahesh, Mahadevappa ;
Grant, Katharine L. ;
Fishman, Elliot K. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (01) :37-41
[17]   Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses [J].
Rastogi, Shivam ;
Singh, Ramandeep ;
Borse, Riddhi ;
Valkovic Zujic, Petra ;
Segota, Doris ;
Diklic, Ana ;
Jurkovic, Slaven ;
Ali, Antar ;
Mohammed Kharita, Hassan ;
Al-Naemi, Huda M. ;
Alkalbani, Jokha ;
Al-Rasbi, Amaal ;
Gershan, Vesna ;
Galic, Stipe ;
Yusuf, Mohammad ;
Avramova-Cholakova, Simona ;
Zulkipli, Ili Majidah Binti Hj ;
Shein, Nilar ;
Teferi, Seife ;
Rehani, Madan M. ;
Vassileva, Jenia ;
Kalra, Mannudeep K. .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2021, 72 (03) :381-387
[18]   Enhanced yield of chromosome aberrations after CT examinations in paediatric patients [J].
Stephan, G. ;
Schneider, K. ;
Panzer, W. ;
Walsh, L. ;
Oestreicher, U. .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2007, 83 (05) :281-287
[19]   Cytogenetic endpoints and Xenobiotic gene polymorphism in lymphocytes of hospital workers chronically exposed to ionizing radiation in Cardiology, Radiology and Orthopedic Laboratories [J].
Vellingiri, Balachandar ;
Shanmugam, Sureshkumar ;
Subramaniam, Mohana Devi ;
Balasubramanian, Balamuralikrishnan ;
Meyyazhagan, Arun ;
Alagamuthu, Karthickkumar ;
Prakash, Varsha ;
Shafiahammedkhan, Mustaqahammed ;
Kathannan, Sankar ;
Pappuswamy, Manikantan ;
Raviganesh, Banu ;
Anand, Sheelapriyadharshinee ;
Dharwadkar, Shahnaz N. ;
Cho, Ssang-Goo ;
Keshavarao, Sasikala .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2014, 100 :266-274
[20]   Enhanced radiation damage caused by iodinated contrast agents during CT examination [J].
Wang, Ling ;
Li, Qiang ;
Wang, Ming ;
Hao, Guang-Yu ;
Jie-Bao ;
Hu, Su ;
Hu, Chun-Hong .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 92 :72-77