Seismic response of structures with friction pendulum inerter system (FPIS) under near-fault earthquakes

被引:0
|
作者
Xue, Zhang [1 ]
Men, Jinjie [1 ,2 ]
Qiang, Rong [3 ]
机构
[1] Xian Univ Architecture & Technol, Coll Architecture, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian, Peoples R China
[3] Yantai Univ, Coll Civil Engn, Yantai 264005, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Base isolation; friction pendulum system; inerter system; maximum displacement of isolation layer; acceleration response of superstructure; TUNED MASS DAMPER; HOMOGENEOUS FRICTION; PERFORMANCE; DESIGN; BUILDINGS; MITIGATION; BEARINGS; BRIDGE;
D O I
10.1177/13694332241252283
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Near-fault ground motions with high acceleration peaks and long-period velocity pulses pose a serious threat to the reliability of engineering structures. To reduce the displacement of isolation layer and improve the seismic performance of superstructure under the near-fault ground motions, a composite isolation system, which is composed of friction pendulum system (FPS) and inerter system, namely FPIS, was used in this paper. Based on D'Alembert's principle, the nonlinear motion equations of a base-isolated structure with FPIS were established. The damping effect of two different mechanical layouts of FPIS subsystems, i.e, series-parallel inerter system-I-FPS(SPIS-I-FPS) or series-parallel inerter system-II-FPS(SPIS-II-FPS), were investigated in this study. The strong nonlinearity of FPIS was considered, and the inerter system parameters were designed based on the principle of maximum damping enhancement. The fourth-order Runge-Kutta approach was used to solve the dynamic response of a multi-degree-of-freedom system under seismic excitations. The effectiveness of FPIS was verified by comparing the isolation layer displacement and the acceleration of superstructure calculated by MATLAB with the friction pendulum system and viscous damper (FPS-VD). The nonlinear time history analysis results indicate that within a certain additional damping range, the SPIS-I-FPS subsystem performs effectively than SPIS-II-FPS in reducing the superstructure acceleration and isolation layer displacement. To increase the energy dissipation efficiency of structures, it is recommended to increase the design parameters of the inerter system and control the friction coefficient of FPS within the range of 0.05 similar to 0.10.
引用
收藏
页码:1547 / 1563
页数:17
相关论文
共 50 条
  • [21] Hybrid RNC-isolation of Structures Under Near-fault Earthquakes
    Ismail, Mohammed
    Pozo, Francesc
    Rodellar, Jose
    2012 AMERICAN CONTROL CONFERENCE (ACC), 2012, : 6132 - 6139
  • [22] Seismic response of subway station structures under straight-down near-fault
    Liu, Ying
    Zhuang, Haiyang
    Zhang, Ji
    Zhou, Zhenwei
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2024, 46 (04): : 843 - 852
  • [23] Acceleration amplification due to rotational components of near-fault earthquakes in triple concave friction pendulum base-isolated structures
    Tajammolian, Hamed
    Khoshnoudian, Faramarz
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2018, 45 (04) : 314 - 327
  • [24] The effect of near-fault earthquakes and wavelet-generated artificial near-fault earthquakes on the seismic behavior of rockfill dams
    Sun, Benbo
    Deng, Mingjiang
    Zhang, Sherong
    Wang, Chao
    Cui, Wei
    Du, Min
    Lai, Yishu
    STRUCTURES, 2023, 58
  • [25] Seismic Collapse Risk Assessment of Braced Frames under Near-Fault Earthquakes
    Sonwani, Jeet Kumar
    Jia, Gaofeng
    Mahmoud, Hussam N.
    Wang, Zhenqiang
    METALS, 2021, 11 (08)
  • [26] Investigation on Seismic Behavior of Historical Tokatli Bridge under Near-Fault Earthquakes
    Karalar, Memduh
    Yesil, Mustafa
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [27] Reliability of semi-active seismic isolation under near-fault earthquakes
    Oncu-Davas, Seda
    Alhan, Cenk
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 114 (146-164) : 146 - 164
  • [28] Improving seismic performance of steel structures due to near-fault earthquakes using hybrid damping system
    Zahrai, S. M.
    Tokhmpash, A.
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 707 - 711
  • [29] Parametric Study of SMA-based Friction Pendulum System for Response Control of Bridges under Near-Fault Ground Motions
    Zheng, Wen-Zhi
    Wang, Hao
    Li, Jian
    Shen, Hui-Jun
    JOURNAL OF EARTHQUAKE ENGINEERING, 2021, 25 (08) : 1494 - 1512
  • [30] Simulated Response of Bridges with Advanced Materials under Near-Fault Earthquakes
    Cruz-Noguez, Carlos A.
    Saiidi, Mehdi
    LATEST TRENDS ON ENGINEERING MECHANICS, STRUCTURES, ENGINEERING GEOLOGY, 2010, : 429 - +