Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study

被引:1
|
作者
Jengojan, Suren [1 ]
Sorgo, Philipp [1 ,2 ]
Streicher, Johannes [2 ]
Snoj, Ziga [3 ]
Kasprian, Gregor [1 ]
Gruber, Gerlinde [2 ]
Bodner, Gerd [4 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Karl Landsteiner Univ Hlth Sci, Dept Anat & Dev Biol, Dr Karl Dorrek Str 30, A-3500 Krems An Der Donau, Austria
[3] Univ Med Ctr Ljubljana, Inst Radiol, Zaloska 7, Ljubljana 1000, Slovenia
[4] Neuromuscular Imaging Ordinationszentrum Dobling, Heiligenstadter Str 46-48, A-1190 Vienna, Austria
来源
RADIOLOGIA MEDICA | 2024年 / 129卷 / 10期
关键词
Ultrasonography; Fingers; Decompression; Ligaments; Cadavers; TRIGGER FINGER; PERCUTANEOUS RELEASE; SAFETY; MANAGEMENT; EFFICACY; SURGERY; KNIFE;
D O I
10.1007/s11547-024-01875-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess and compare two ultrasound-guided, minimally invasive procedures to release the A1-pulley (needle release and thread release) regarding efficacy and safety in an anatomical specimen model. Materials and methods Twenty-one ultrasound-guided needle releases and 20 ultrasound-guided thread releases were performed on digits of Thiel-embalmed anatomical specimens. A scoring system was developed to assess ultrasound visibility, intervention outcome (incomplete, almost complete, or full transection of the A1 pulley), and injury to adjacent structures (neurovascular structures, tendons, A2 pulley). Statistical analysis was performed to compare the score of the two groups (group 1: needle release, group 2: thread release). A P-value of <= 0.05 was considered significant. Results Needle release was completely successful in 15 cases (71.5%), almost complete release was achieved in four cases (19%), and incomplete transection occurred in two cases (9.5%). Thread release was completely successful in 17 cases (85%), and almost complete transection was observed in the remaining three cases (15%). In both procedures no neurovascular structures were harmed. Slight injury of flexor tendons occurred in two cases (9.5%) in needle release and in five cases (25%) in thread release. There were no significant statistical differences between the groups regarding ultrasound visibility, intervention safety and outcome, (P > 0.05). Conclusion Ultrasound-guided needle release and ultrasound-guided thread release have similar success of release, both being effective and safe techniques for the release of the A1 pulley. [GRAPHICS] .
引用
收藏
页码:1513 / 1521
页数:9
相关论文
共 50 条
  • [31] Endobronchial ultrasound-guided transbronchial needle aspiration
    Medford, A. R. L.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2010, 64 (13) : 1773 - 1783
  • [32] Endobronchial ultrasound-guided transbronchial needle aspiration
    Labarca, Gonzalo
    Caviedes, Ivan
    Folch, Erik
    Majid, Adnan
    Fernandez-Bussy, Sebastian
    REVISTA MEDICA DE CHILE, 2017, 145 (09) : 1165 - 1171
  • [33] Endobronchial ultrasound-guided transbronchial needle aspiration
    Medford, Andrew R. L.
    POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ-POLISH ARCHIVES OF INTERNAL MEDICINE, 2010, 120 (11): : 459 - 466
  • [34] Endoscopic Ultrasound-Guided Fine Needle Aspiration
    Brass, Volker
    Thimme, Robert
    Will, Uwe
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2017, 142 (05) : 371 - 375
  • [35] Ameboma in ultrasound-guided fine needle aspiration
    Bhat, DM
    Pangarkar, MA
    Gadkari, RU
    Lele, VR
    Bobhate, SK
    ACTA CYTOLOGICA, 2004, 48 (06) : 873 - 875
  • [36] A Comparison of Blinded versus Ultrasound-Guided Limited-Open Trigger Finger Release Using the Yasunaga Knife
    Muramatsu, Keiichi
    Rayel, Ma Felma
    Arcinue, Jasson
    Tani, Yasuhiro
    Kobayashi, Masato
    Seto, Tetsuya
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (01) : 124 - 129
  • [37] Combination of ultrasound-guided percutaneous A1 pulley release and intra-tendon sheath injection improves the therapeutic outcomes in adult trigger finger patients
    Zan, Xing-You
    Zhou, Wei-Ping
    Wang, Yan
    Xu, Min
    Zhou, Feng-Sheng
    Fang, Xiang-Ming
    MEDICAL ULTRASONOGRAPHY, 2023, 25 (02) : 153 - 160
  • [38] Ultrasound-guided intervention for hip joint
    Francavilla, G.
    Sutera, R.
    Iovane, A.
    Gagliardo, C.
    Candela, F.
    Sanfilippo, A.
    Francavilla, V. C.
    Lo Casto, A.
    Midiri, M.
    MEDICINA DELLO SPORT, 2013, 66 (01) : 91 - 100
  • [39] ULTRASOUND-GUIDED TALONAVICULAR ARTHROCENTESIS
    Thom, Christopher
    Pozner, Jonathan
    Kongkatong, Matthew
    Moak, James
    JOURNAL OF EMERGENCY MEDICINE, 2020, 60 (05) : 633 - 636
  • [40] Ultrasound-Guided Musculoskeletal Injections
    Lin, Jonathan S.
    Gimarc, David C.
    Adler, Ronald S.
    Beltran, Luis S.
    Merkle, Alexander N.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2021, 25 (06) : 769 - 784