Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study

被引:3
作者
Jengojan, Suren [1 ]
Sorgo, Philipp [1 ,2 ]
Streicher, Johannes [2 ]
Snoj, Ziga [3 ]
Kasprian, Gregor [1 ]
Gruber, Gerlinde [2 ]
Bodner, Gerd [4 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Karl Landsteiner Univ Hlth Sci, Dept Anat & Dev Biol, Dr Karl Dorrek Str 30, A-3500 Krems An Der Donau, Austria
[3] Univ Med Ctr Ljubljana, Inst Radiol, Zaloska 7, Ljubljana 1000, Slovenia
[4] Neuromuscular Imaging Ordinationszentrum Dobling, Heiligenstadter Str 46-48, A-1190 Vienna, Austria
来源
RADIOLOGIA MEDICA | 2024年 / 129卷 / 10期
关键词
Ultrasonography; Fingers; Decompression; Ligaments; Cadavers; TRIGGER FINGER; PERCUTANEOUS RELEASE; SAFETY; MANAGEMENT; EFFICACY; SURGERY; KNIFE;
D O I
10.1007/s11547-024-01875-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess and compare two ultrasound-guided, minimally invasive procedures to release the A1-pulley (needle release and thread release) regarding efficacy and safety in an anatomical specimen model. Materials and methods Twenty-one ultrasound-guided needle releases and 20 ultrasound-guided thread releases were performed on digits of Thiel-embalmed anatomical specimens. A scoring system was developed to assess ultrasound visibility, intervention outcome (incomplete, almost complete, or full transection of the A1 pulley), and injury to adjacent structures (neurovascular structures, tendons, A2 pulley). Statistical analysis was performed to compare the score of the two groups (group 1: needle release, group 2: thread release). A P-value of <= 0.05 was considered significant. Results Needle release was completely successful in 15 cases (71.5%), almost complete release was achieved in four cases (19%), and incomplete transection occurred in two cases (9.5%). Thread release was completely successful in 17 cases (85%), and almost complete transection was observed in the remaining three cases (15%). In both procedures no neurovascular structures were harmed. Slight injury of flexor tendons occurred in two cases (9.5%) in needle release and in five cases (25%) in thread release. There were no significant statistical differences between the groups regarding ultrasound visibility, intervention safety and outcome, (P > 0.05). Conclusion Ultrasound-guided needle release and ultrasound-guided thread release have similar success of release, both being effective and safe techniques for the release of the A1 pulley. [GRAPHICS] .
引用
收藏
页码:1513 / 1521
页数:9
相关论文
共 31 条
[1]   A cadaveric assessment of percutaneous trigger finger release with 15° stab knife: its effectiveness and complications [J].
Abdoli, Abbas ;
Asadian, Majid ;
Banadaky, Seyed Houssein Saeed ;
Sarram, Rabeah .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
[2]   High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz [J].
Albano, Domenico ;
Aringhieri, Giacomo ;
Messina, Carmelo ;
De Flaviis, Luca ;
Sconfienza, Luca Maria .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2020, 24 (02) :125-134
[3]   PERCUTANEOUS A1 PULLEY RELEASE - A CADAVERIC STUDY [J].
BAIN, GI ;
TURNBULL, J ;
CHARLES, MN ;
ROTH, JH ;
RICHARDS, RS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (05) :781-784
[4]   Comparison of fresh and Thiel's embalmed cadavers according to the suitability for ultrasound-guided regional anesthesia of the cervical region [J].
Benkhadra, Mehdi ;
Faust, Alexandre ;
Ladoire, Sylvain ;
Trost, Olivier ;
Trouilloud, Pierre ;
Girard, Claude ;
Anderhuber, Friedrich ;
Feigl, Georg .
SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (07) :531-535
[5]   CLINICAL UPDATES Acquired triggering of the fingers and thumb in adults [J].
David, Michael ;
Rangaraju, Madhav ;
Raine, Andrew .
BMJ-BRITISH MEDICAL JOURNAL, 2017, 359 :j5285
[6]   Anatomical Study of the A1 Pulley: Length and Location by Means of Cutaneous Landmarks on the Palmar Surface [J].
Fiorini, Harold J. ;
Santos, Joao B. G. ;
Hirakawa, Celso K. ;
Sato, Edson S. ;
Faloppa, Flavio ;
Albertoni, Walter M. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (03) :464-468
[7]   Current Concepts in the Management of Trigger Finger in Adults [J].
Gil, Joseph A. ;
Hresko, Andrew M. ;
Weiss, Arnold-Peter C. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (15) :E642-E650
[8]   Sonographic appearance of trigger fingers [J].
Guerini, Henri ;
Pessis, Eric ;
Theumann, Nicolas ;
Le Quintrec, Janine-Sophie ;
Campagna, Raphael ;
Chevrot, Alain ;
Feydy, Antoine ;
Drape, Jean-Luc .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (10) :1407-1413
[9]   Minimally invasive thread trigger digit release: a preliminary report on 34 digits of the adult hands [J].
Guo, Danqing ;
McCool, Logan ;
Senk, Alexander ;
Tonkin, Brionn ;
Guo, Joseph ;
Lytie, Rachel M. ;
Guo, Danzhu .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) :942-947
[10]  
Guo Danqing, 2018, Hand (N Y), V13, P170, DOI 10.1177/1558944717697433