Impact of Communication Time Delay in a 5G Network on Frequency Regulation Performance of a High Renewable Energy Penetrated Power System

被引:2
|
作者
He, Hongjie [1 ]
Cai, Xiao [1 ]
Su, Yibo [2 ]
Zhang, Xianfeng [2 ]
Zhang, Ning [1 ]
Ci, Song [1 ]
Zhou, Yanglin [1 ]
Kang, Chongqing [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] China Three Gorges Corp, Sci & Technol Res Inst, Beijing 100036, Peoples R China
来源
IEEE INTERNET OF THINGS JOURNAL | 2024年 / 11卷 / 14期
关键词
Delay effects; Frequency control; 5G mobile communication; Backhaul networks; Automatic generation control; Time-frequency analysis; Radio access networks; Distributed resource; fifth-generation (5G) network; frequency regulation performance; high renewable energy penetrated power system; impact of time delay; WIRELESS BACKHAUL; TRANSMISSION; INCLUSION; CAPACITY; LATENCY; STORAGE; DESIGN; MODEL;
D O I
10.1109/JIOT.2023.3332733
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The fifth-generation (5G) communication technology development makes it possible for distributed resources to participate in power system frequency regulation. This article models the whole-chain communication time delay of distributed frequency regulation resources participating in automatic generation control (AGC) via a 5G network. The whole-chain communication time delay consists of time delay in the radio access network, backhaul network, and transmission and core networks. We integrate the time-delay model into the power system frequency regulation model to reveal its impact on frequency regulation performance. In addition, we analyze the feasibility of the distributed variable renewable energy (VRE) participating in AGC and calculate the capabilities needed for different VRE penetrations. Finally, we provide a case study on the HRP-38 system. The results show that the communication time delay will substantially impact the frequency regulation performance when the VRE penetration is above 40%. In addition, distributed VRE may be a promising AGC resource. Distributed VRE that accounts for approximately 5% of the total installed VRE capacity is needed to participate in AGC via a 5G network, which could maintain the frequency performance of the power system with above 65% VRE penetrated at a normal level.
引用
收藏
页码:24376 / 24388
页数:13
相关论文
共 50 条
  • [1] Communication Resources Allocation for Time Delay Reduction of Frequency Regulation Service in High Renewable Penetrated Power System
    He, Hongjie
    Zhang, Ning
    Kang, Chongqing
    Ci, Song
    Teng, Fei
    Strbac, Goran
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2024, 10 (02): : 468 - 480
  • [2] Efficient frequency regulation in highly penetrated power systems by renewable energy sources using stochastic fractal optimiser
    El-Hameed, Mohamed A.
    Elkholy, Mahmoud M.
    El-Fergany, Attia A.
    IET RENEWABLE POWER GENERATION, 2019, 13 (12) : 2174 - 2183
  • [3] High penetrated renewable energy sources-based AOMPC for microgrid's frequency regulation during weather changes, time-varying parameters and generation unit collapse
    Abazari, Ahmadreza
    Soleymani, Mohammad Mahdi
    Babaei, Masoud
    Ghafouri, Mohsen
    Monsef, Hassan
    Beheshti, Mohammad T. H.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (22) : 5164 - 5182
  • [4] Performance Analysis of IoT Network over 5G Communication
    Sanvika, V.
    Singh, Indrasen
    Chandra, Madala Poorna
    Reddy, Joshith
    COMPUTING SCIENCE, COMMUNICATION AND SECURITY, COMS2 2024, 2025, 2174 : 78 - 88
  • [5] Dynamic Performance Improving Strategy for Primary Frequency Regulation With Energy Storages in High Penetration of RESs Power System
    He, Li
    Guo, Luoquan
    Tan, Zhuangxi
    Chen, Chaoyang
    Li, Xinran
    Huang, Jiyuan
    Li, Xueyuan
    IEEE ACCESS, 2024, 12 : 139560 - 139572
  • [6] Impact of storage device on Load frequency control of a two-area renewable penetrated power system
    Jood, Pankaj
    Aggarwal, S. K.
    Chopra, Vikram
    2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2018,
  • [7] Frequency and Voltage Stabilization of Multiarea Hybrid Power System by Considering the Impact of Communication Time Delay
    Gulzar, Muhammad Majid
    Irfan, Rasmia
    Shahid, Kamal
    Raza, Muhammad Taskeen
    Javed, Imran
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023,
  • [8] Coordinated restoration of inverter-based power sources and synchronous generators for the high renewable penetrated power system considering the dynamic frequency regulation capability
    Yang, Chao
    Liao, Huanxin
    Liang, Gaoqi
    Gao, Huisheng
    Xin, Huanhai
    Zhao, Junhua
    IET RENEWABLE POWER GENERATION, 2024, 18 (07) : 1292 - 1303
  • [9] Impact of Communication Delay on Load Frequency Control of Interconnected Power System
    Singh, Vijay P.
    Pandey, S. K.
    Agrawal, Sanjay
    Singh, Navdeep
    2018 5TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (UPCON), 2018, : 440 - 445
  • [10] Impact of renewable energy penetration rate on power system frequency stability
    Qin, Boyu
    Wang, Mingjie
    Zhang, Gang
    Zhang, Zhe
    ENERGY REPORTS, 2022, 8 : 997 - 1003