Study of LED Retrofit Lamps in HSPV Luminaires Based on Photometric Method for Road Lighting

被引:2
作者
Jamaludin, Mohd Hanif [1 ,2 ]
Ismail, Wan Zakiah Wan [1 ,2 ]
Husini, Elina Mohd [3 ]
Bahror, Nor Ain Mohd [2 ]
机构
[1] Univ Sains Islam Malaysia, Fac Engn & Built Environm, Adv Device & Syst, Nilai 71800, Negeri Sembilan, Malaysia
[2] Jabatan Kerja Raya Malaysia, Ctr Excellence Technol & Engn CREaTE, Alor Gajah 78000, Melaka, Malaysia
[3] Univ Sains Islam Malaysia, Fac Engn & Built Environm, Sustainable Energy Technol, Nilai 71800, Negeri Sembilan, Malaysia
来源
PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY | 2024年 / 32卷 / 03期
关键词
High-pressure sodium vapor; light emitting diode; light intensity distribution curve; light output ratio;
D O I
10.47836/pjst.32.3.11
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Energy reduction is a great challenge in road lighting applications. Replacing high-pressure sodium vapor (HPSV) with light-emitting diodes (LED) is a viable approach to reducing energy consumption. However, a total replacement can incur a significant capital cost. This study aims to investigate the effects on light distribution by replacing HPSV lamps with LED lamps in HPSV luminaires using Light Intensity Distribution (LID) curve measurement and Backlight, Uplight and Glare (BUG) rating evaluation to reduce the adoption costs. While LED lamps have high illumination rates, the structural differences from HPSV lamps can affect the LID curve and original lighting design. Therefore, it is crucial to study photometric dispersion after retrofitting light sources. Both lamps were installed into similar HPSV luminaires to assess photometric performance using goniophotometer measurements. The HPSV lamp outperforms the LED lamp in terms of luminous flux (11.13%) and light intensity (7.69%), whereas the LED lamp outperforms the HPSV lamp in terms of efficacy rating (68.67%) and wattage used (47.61%). The findings indicate that retrofit LED luminaires have an LOR of 46.77% lower than the HPSV luminaires. The light distribution pattern is maintained but reduced to 40 to 50% for the main usable light angles. The reduced performance is caused by the lamp structure, which occupies a large area inside the luminaire housing, obstructing proper light distribution. Although overall energy consumption is reduced, similar illumination levels cannot be maintained. These outcomes can assist authorities and manufacturers with alternative methods of reducing costs while maintaining lighting levels.
引用
收藏
页码:1187 / 1201
页数:15
相关论文
共 25 条
[1]  
Abdullah A, 2021, Indonesian Journal of Computing Engineering and Design (IJoCED), V3, P54, DOI [10.35806/ijoced.v3i1.153, 10.35806/ijoced.v3i1.153, DOI 10.35806/IJOCED.V3I1.153]
[2]  
Bamisile OO, 2016, Energy and Policy Research, V3, P27, DOI [10.1080/23815639.2016.1201442, 10.1080/23815639.2016.1201442, DOI 10.1080/23815639.2016.1201442]
[3]   A practical method of comparing luminous intensity distributions [J].
Bergen, A. S. J. .
LIGHTING RESEARCH & TECHNOLOGY, 2012, 44 (01) :27-36
[4]  
BERNAMA, 2023, 212,639 Street Bulbs Replaced with LED Lights-TNB
[5]   Modelling of the effects of luminaire installation geometries and other factors on road illumination system photometric parameters and energy efficiency [J].
Bhattacharya, Sourin ;
Majumder, Sanjib ;
Roy, Subarna .
WORLD JOURNAL OF ENGINEERING, 2025, 22 (04) :674-688
[6]  
Braga MF, 2014, 11 IEEEIAS INT C IND
[7]  
Bredemeier K, 2017, Photometric Data for the Development of Lighting Components
[8]  
British Standard, 2015, BSI Standards Publication
[9]   Rational Basis for Light Emitting Diode Street Lighting Retrofit Luminaire Selection [J].
Brons, Jennifer A. ;
Bullough, John D. ;
Frering, Daniel C. .
TRANSPORTATION RESEARCH RECORD, 2021, 2675 (09) :634-638
[10]   IES TM-15 BUG Value-Setting and Adjustment Methodology [J].
Chinnis, Darcie ;
Mutmansky, Michael ;
Clanton, Nancy .
LEUKOS, 2011, 8 (01) :25-39