Evaluation of the Minimum Segment Width and Fluence Smoothing Tools for Intensity-modulated Techniques in Monaco Treatment Planning System

被引:1
作者
Jimenez-Puertas, Sara [1 ]
Rodriguez, Andrea Gonzalez [1 ]
Cordero, Sergio Lozares [1 ]
Gonzalez, Tomas Gonzalez [1 ]
Chamarro, Javier Diez [1 ]
Hernandez, Monica Hernandez [1 ]
Moreno, Raquel Castro [1 ]
Casi, Marta Sanchez [1 ]
Gazulla, David Carlos Villa [1 ]
Martinez, Almudena Gandia [1 ]
Bonel, Arantxa Campos [1 ]
Valino, Maria del Mar Puertas [1 ]
Gomez, Jose Antonio Font [1 ]
机构
[1] Univ Hosp Miguel Servet, Dept Med Phys & Radiat Protect, P Isabel Catolica 1-3, Zaragoza 50009, Spain
关键词
Minimum segment width; monitor units; radiosurgery; volumetric-modulated arc therapy; RADIATION-THERAPY; RADIOTHERAPY; ARC; QUALITY;
D O I
10.4103/jmp.jmp_156_23
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to minimize monitor units (MUs) of intensity-modulated treatments in the Monaco treatment planning system while preserving plan quality by optimizing the "Minimum Segment Width" (MSW) and "Fluence Smoothing" parameters. Materials and Methods: We retrospectively analyzed 30 prostate, 30 gynecological, 15 breast cancer, 10 head and neck tumor, 11 radiosurgery, and 10 hypo-fractionated plans. Original prostate plans employed "Fluence Smoothing" = Off and were reoptimized with Low, Medium, and High settings. The remaining pathologies initially used MSW = 0.5 cm and were reoptimized with MSW = 1.0 cm. Plan quality, including total MU, delivery time, and dosimetric constraints, was statistically analyzed with a paired t-test. Results: Prostate plans exhibited the highest MU variation when changing "Fluence Smoothing" from Off to High (average Delta MU = -5.1%; P < 0.001). However, a High setting may increase overall MU when MSW = 0.5 cm. Gynecological plans changed substantially when MSW increased from 0.5 cm to 1.0 cm (average Delta MU = -29%; P < 0.001). Organs at risk sparing and planning target volumes remained within 1.2% differences. Replanning other pathologies with MSW = 1.0 cm affected breast and head and neck tumor plans (average Delta MU = -168.38, average Delta t = -11.74 s, and average Delta MU = -256.56, average Delta t = -15.05 s, respectively; all with P < 0.004). Radiosurgery and hypofractioned highly modulated plans did not yield statistically significant results. Conclusions: In breast, pelvis, head and neck, and prostate plans, starting with MSW = 1.0 cm optimally reduces MU and treatment time without compromising plan quality. MSW has a greater impact on MU than the "Fluence Smoothing" parameter. Plans with high modulation might present divergent behavior, requiring a case-specific analysis with MSW values higher than 0.5 cm.
引用
收藏
页码:250 / 260
页数:13
相关论文
共 19 条
[1]   Comparison of radiotherapy techniques with flattening filter and flattening filter-free in lung radiotherapy according to the treatment volume size [J].
Arslan, Alaettin ;
Sengul, Burak .
SCIENTIFIC REPORTS, 2020, 10 (01)
[2]   Radiotherapy-induced malignancies: review of clinical features, pathobiology, and evolving approaches for mitigating risk [J].
Braunstein, Steve ;
Nakamura, Jean L. .
FRONTIERS IN ONCOLOGY, 2013, 3
[3]   Second cancers after radiotherapy: update and recommandations [J].
Cosset, J. -M. ;
Hetnal, M. ;
Chargari, C. .
RADIOPROTECTION, 2018, 53 (02) :101-105
[4]   Efficacy of flattening-filter-free beam in stereotactic body radiation therapy planning and treatment: A systematic review with meta-analysis [J].
Dang, Thu M. ;
Peters, Mitchell J. ;
Hickey, Brigid ;
Semciw, Adam .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (03) :379-387
[5]   Radiation induced secondary malignancies: a review article [J].
Dracham, Chinna Babu ;
Shankar, Abhash ;
Madan, Renu .
RADIATION ONCOLOGY JOURNAL, 2018, 36 (02) :85-94
[6]   The Role of Particle Therapy in the Risk of Radio-induced Second Tumors: A Review of the Literature [J].
Facoetti, Angelica ;
Barcellini, Amelia ;
Valvo, Francesca ;
Pullia, Marco .
ANTICANCER RESEARCH, 2019, 39 (09) :4613-4617
[7]   A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer [J].
Foroudi, Farshad ;
Wilson, Lesley ;
Bressel, Mathias ;
Haworth, Annette ;
Hornby, Colin ;
Pham, Daniel ;
Cramb, Jim ;
Gill, Suki ;
Tai, Keen Hun ;
Kron, Tomas .
RADIATION ONCOLOGY, 2012, 7
[8]   What is plan quality in radiotherapy? The importance of evaluating dose metrics, complexity, and robustness of treatment plans [J].
Hernandez, Victor ;
Hansen, Christian Ronn ;
Widesott, Lamberto ;
Back, Anna ;
Canters, Richard ;
Fusella, Marco ;
Gotstedt, Julia ;
Jurado-Bruggeman, Diego ;
Mukumoto, Nobutaka ;
Kaplan, Laura Patricia ;
Koniarova, Irena ;
Piotrowski, Tomasz ;
Placidi, Lorenzo ;
Vaniqui, Ana ;
Jornet, Nuria .
RADIOTHERAPY AND ONCOLOGY, 2020, 153 :26-33
[9]   Optimization of Minimum Segment Width Parameter in the Intensity-Modulated Radiotherapy Plan for Esophageal Cancer [J].
Hong, Jun ;
Han, Ji-Hua ;
Luo, Hong-Lei ;
Song, Ya-Qi .
INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 :9913-9921
[10]   Influence of segment width on plan quality for volumetric modulated arc based stereotactic body radiotherapy [J].
Nithiyanantham, Karthikeyan ;
Mani, Ganesh Kadirampatti ;
Subramani, Vikraman ;
Palaniappan, Karrthick Karukkupalayam ;
Uthiran, Mohanraj ;
Vellengiri, Sennniandavar ;
Raju, Sambasivaselli ;
Supe, Sanjay S. ;
Kataria, Tejinder .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (05) :287-295