First-in-human clinical series of a novel conformable large-lattice pulsed field ablation catheter for pulmonary vein isolation

被引:8
作者
Reddy, Vivek Y. [1 ,2 ]
Anter, Elad [3 ]
Peichl, Petr [4 ]
Rackauskas, Gediminas [5 ]
Petru, Jan [2 ]
Funasako, Moritoshi [2 ]
Koruth, Jacob S. [1 ]
Marinskis, Germanas [5 ]
Turagam, Mohit [1 ]
Aidietis, Audrius [5 ]
Kautzner, Josef [4 ]
Natale, Andrea [6 ,7 ]
Neuzil, Petr [2 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Cardiol, One Gustave Levy Pl,Box 1030, New York, NY 10029 USA
[2] Homolka Hosp, Dept Cardiol, Prague, Czech Republic
[3] Shamir Med Ctr, Div Cardiovasc Med, Tel Aviv, Israel
[4] Inst Clin & Expt Med IKEM, Dept Cardiol, Prague, Czech Republic
[5] Vilnius Univ, Dept Cardiol, Vilnius, Lithuania
[6] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX USA
[7] Univ Tor Vergata, Dept Biomed & Prevent, Div Cardiol, Rome, Italy
来源
EUROPACE | 2024年 / 26卷 / 04期
关键词
Atrial fibrillation; Single-shot; Catheter ablation; Pulsed field ablation; Lesion durability; Electroanatomical mapping system; PAROXYSMAL ATRIAL-FIBRILLATION; RADIOFREQUENCY; OUTCOMES;
D O I
10.1093/europace/euae090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system.Methods and results After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; similar to 4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted similar to 75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 +/- 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 +/- 21.6, 10.0 +/- 6.0, 19.1 +/- 9.3, and 5.7 +/- 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort.Conclusion Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping. Graphical Abstract
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation
    Kawamura, Iwanari
    Neuzil, Petr
    Shivamurthy, Poojita
    Petru, Jan
    Funasako, Moritoshi
    Minami, Kentaro
    Kuroki, Kenji
    Dukkipati, Srinivas R.
    Koruth, Jacob S.
    Reddy, Vivek Y.
    HEART RHYTHM, 2021, 18 (06) : 878 - 884
  • [32] Evaluation of Pulmonary Vein Stenosis After Pulmonary Vein Isolation Using a Novel Circular Mapping and Ablation Catheter (PVAC)
    von Bary, Christian
    Weber, Stefan
    Dornia, Christian
    Eissnert, Christoph
    Fellner, Claudia
    Latzin, Philipp
    Fredersdorf, Sabine
    Stadler, Stefan
    Hamer, Okka W.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05) : 630 - 636
  • [33] Pulsed field ablation and cryoballoon ablation for pulmonary vein isolation: insights on efficacy, safety and cardiac function
    Rattka, Manuel
    Mavrakis, Evangelos
    Vlachopoulou, Dimitra
    Rudolph, Isabel
    Kohn, Christina
    Bohnen, Jan
    Yahsaly, Loubna
    Siebermair, Johannes
    Wakili, Reza
    Jungen, Christiane
    Rassaf, Tienush
    Mathew, Shibu
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (05) : 1191 - 1198
  • [34] Pulmonary vein isolation in atrial fibrillation using pulsed field ablation
    Lindemann, F.
    Nedios, S.
    Seewoester, T.
    Hindricks, G.
    HERZ, 2021, 46 (04) : 318 - 322
  • [35] First data on cardiac mapping and outcome of pulmonary vein isolation using a novel ablation catheter with tip mini electrodes
    Loehr, Lena
    Lask, Sebastian
    Heringhaus, Florian
    Lotz, Tanja
    Kara, Kaffer
    Muegge, Andreas
    Wutzler, Alexander
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 274 : 122 - 125
  • [36] Characterization of durability and reconnection patterns at time of repeat ablation after single-shot pulsed field pulmonary vein isolation
    Ruwald, Martin H.
    Haugdal, Martin
    Worck, Rene
    Johannessen, Arne
    Hansen, Morten Lock
    Sorensen, Samuel K.
    Hansen, Jim
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (02) : 379 - 387
  • [37] Comprehensive dose-response study of pulsed field ablation using a circular catheter compared with radiofrequency ablation for pulmonary vein isolation: A preclinical study
    Hsu, Jonathan C.
    Banker, Rajesh S.
    Gibson, Douglas N.
    Gomez, Tara
    Berman, Dror
    Datta, Keshava
    Chen, Qi
    Doshi, Shephal K.
    HEART RHYTHM O2, 2023, 4 (10): : 662 - 667
  • [38] Radiofrequency catheter ablation for re-do procedure after single-shot pulmonary vein isolation with pulsed field ablation for paroxysmal atrial fibrillation: case report
    Yang, Xinyan
    Lin, Mingjie
    Zhang, Yan
    Wang, Juntao
    Zhong, Jingquan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [39] Comparison of pulsed-field ablation versus very high power short duration-ablation for pulmonary vein isolation
    Woermann, Jonas
    Schipper, Jan-Hendrik
    Lueker, Jakob
    van den Bruck, Jan-Hendrik
    Filipovic, Karlo
    Erlhoefer, Susanne
    Pavel, Friederike
    Scheurlen, Cornelia
    Dittrich, Sebastian
    Steven, Daniel
    Sultan, Arian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (12) : 2417 - 2424
  • [40] First report of phrenic nerve injury during pulmonary vein isolation using the Ablation Frontiers pulmonary vein ablation catheter
    Ahsan, Syed Y.
    Flett, Andrew S.
    Lambiase, Pier D.
    Segal, Oliver R.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 29 (03) : 187 - 190