Comparative dosimetric, setup margin, and treatment time analysis between ring gantry and C-Arm linear accelerators for VMAT-based craniospinal irradiation plans

被引:1
|
作者
Biswal, Subhra S. [1 ,2 ]
Sarkar, Biplab [1 ,2 ]
Goyal, Monika [2 ]
机构
[1] Apolo Multispecial Hosp, Dept Radiat Oncol, Kolkata, W Bengal, India
[2] GLA Univ, Depertment Phys, Mathura, Uttar Pradesh, India
关键词
Craniospinal irradiation; CSI; setup margin; VMAT; MODULATED RADIATION-THERAPY; JUNCTION; RADIOTHERAPY;
D O I
10.4103/jcrt.jcrt_1091_22
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study is to evaluate the dosimetric and treatment delivery characteristics of volumetric modulated arc therapy technique (VMAT)-based craniospinal axis irradiation (CSI) between ring gantry Halcyon (HAL) and C-arm based Novalis Tx (NTx) linear accelerator. Set-up margin and treatment delivery time for both machines were also taken into account. Materials and Methods: Fifteen patients, 4 females and 11 males treated between March 2019 and February 2022 within the age group 4-56 years simulated in the supine position and were planned for multiple isocentre VMAT technique in ring gantry Halcyon and C-Arm Novalis linear accelerator for 6FFF and 6 MV flatten beam energy. The number of isocenters was the same in both the machines, usually three for adult adolescent age group patients and two for pediatric patients. Total on-couch time and the patient positional shift were captured for each isocenter during each session of treatment. Margins were calculated using Herk's formula of margin = 2.5 Sigma +0.7 sigma. Dosimetry, on-couch time, and set-up margin were compared between two competing arms. Results: Ninety-five percent of PTV coverage (P = 0.333), volume receiving 107% (P = 0.676), total MU (P = 0.818) in both the arms were comparable and statically insignificant. Low-dose spillage such as D20% (P = 0.212) and D50% (P = 0.008) was lesser in HAL comparable to NTx. CI and HI were statically insignificant. Out of 26 organs at risk (OAR), only 3 organs showed a statically significant dose difference. The mean and maximum setup margin in any linear direction was 0.45 and 0.53 cm for HAL and 0.37 and 0.56 cm for NTx and, variation was statistically insignificant (0.23 < P < 0.47). On-couch time was 4.0 +/- 5.5 min lesser for HAL and the difference in on-couch time between the two arms was statistically different. Conclusion: Even though the majority of the delivery parameters such as gantry speed, dose rate, beam characteristic (flatten or unflatten), MLC width, and speed between the ring gantry HAL and C-arm NTx linear accelerators were distinctly different, they offered no or minimal difference in the dose distribution and in the setup margin. HAL gives a faster treatment time delivery, which could be crucial for some selective cases such as patients receiving treatment under general anesthesia.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 2 条
  • [1] Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
    Sarkar, Biplab
    Biswal, Subhra Snigdha
    Shahid, Tanweer
    Ghosh, Tanmoy
    Bhattacharya, Jibak
    De, Arundhati
    Mukherjee, Mukti
    Ganesh, Tharmarnadar
    Cozzi, Luca
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Comparative analysis of fetal dose sparing between a C-arm linac and an O-ring linac in a SIB-VMAT sarcoma treatment for a pregnant patient: A technical note and case report
    Rivais, Wesley
    Constine, Louis
    Pacella, Matthew
    Joyce, Neil
    Nagey, Maimuna
    Webster, Matthew
    Yoon, Jihyung
    Jung, Hyunuk
    Tanny, Sean
    Lemus, Olga Maria Dona
    Zheng, Dandan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):