The effect of width and slope in uniclinal V-shaped underground space on air transport and smoke characteristics under thermal stack effect

被引:1
|
作者
Yin, Yaolong [1 ,2 ]
Xu, Zhisheng [1 ,2 ]
Zhao, Jiaming [3 ]
Mahmood, Sohail [1 ,2 ]
Xie, Baochao [1 ,2 ]
Liu, Qiulin [1 ,2 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha 410075, Peoples R China
[2] Cent South Univ, Natl Engn Res Ctr High Speed Railway Construct Tec, Changsha 410075, Peoples R China
[3] CABR Fire Safety Sci &Technol Co Ltd, Beijing 100013, Peoples R China
关键词
Uniclinal V-shaped underground fire; Air transport velocity; Smoke backlayering length; Maximum smoke temperature rise; Cross-sectional width; CRITICAL VELOCITY; MAXIMUM TEMPERATURE; GAS TEMPERATURE; FIRE SAFETY; TUNNEL; PREDICTION; BENEATH; ROAD;
D O I
10.1016/j.tsep.2024.102599
中图分类号
O414.1 [热力学];
学科分类号
摘要
Uniclinal V-shaped structure is common in underground spaces such as mines, tunnels, and subway stations, but few studies have paid attention to its fire smoke movement law. The paper focused on relationships between air transport velocity, smoke backlayering length, and maximum smoke temperature rise with underground space width and slope. The air transport velocity was quantified, a forecasting model of smoke backlayering length was proposed, and the pattern of variation in the maximum temperature rise was unveiled. The findings indicated that the air transport velocity relates to slope height and buoyancy flux per unit width. The slope has a great influence on the air transport velocity. For the low heat release rate, the backlayering length is primarily determined by the underground space geometry, while for the high heat release rate, it is influenced by the air transport velocity. In contrast to the horizontal underground space, the maximum smoke temperature rise of the uniclinic V-shaped underground space exhibited a linear decrease. When the dimensionless slope height is less than or equal to 1.2, the maximum temperature rise is independent of the section width. When the dimensionless slope height is greater than or equal to 1.6, the maximum temperature rise decreases with the lessening of the section width. These findings contribute to a better understanding of smoke movement in uniclinic V-shaped underground spaces under natural ventilation and provide valuable guidance for smoke control strategies.
引用
收藏
页数:17
相关论文
共 41 条
  • [41] Study on the effect of spacing on thermal runaway and smoke temperature of double 32,650 lithium iron phosphate batteries under a narrow and long constrained space
    An, Weiguang
    Kong, Weihao
    Liu, Fengkai
    Wang, Tao
    Wang, Yao
    Wang, Zhi
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (20) : 11215 - 11227