Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study

被引:1
作者
Arceri, Alberto [1 ]
Abdi, Pejman [1 ]
Mazzotti, Antonio [1 ,2 ]
Zielli, Simone Ottavio [1 ]
Artioli, Elena [1 ]
Langone, Laura [1 ]
Sgubbi, Federico [1 ]
Faldini, Cesare [1 ,2 ]
机构
[1] Ist Ortoped Rizzoli, Ist Ricovero & Cura Carattere Sci IRCCS, Orthopaed & Traumatol Clin 1, I-40136 Bologna, Italy
[2] Alma Mater Studiorum Univ Bologna, Dept Biomed & Neuromotor Sci DIBINEM, Bologna, Italy
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 07期
关键词
total ankle arthroplasty; patient-specific instrumentation; surgical outcomes; retrospective analysis; complications; REPLACEMENT; DEFORMITY; OUTCOMES; MOTION; RANGE; VARUS;
D O I
10.3390/jpm14070770
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: This retrospective study aims to compare surgical outcomes between two cohorts of patients who underwent total ankle arthroplasty (TAA) using either standard technique or patient-specific instrumentation (PSI). Methods: A consecutive series of patients who affected of end-staged ankle osteoarthritis were retrospectively assessed and divided into two groups based on TAA techniques: a TAA standard technique group and a TAA-using PSI group. The two groups were compared in terms of operative time, additional procedures, complications (neurovascular and wound problems, infection, loosening and osteolysis, revision and explantation rates, and perioperative fracture), clinical scores, and range of motion (ROM). Result: Fifty-one patients underwent standard TAA, while 13 patients underwent TAA with PSI. At 1-year follow-up, there were no significant differences in complication rates between the two groups (p > 0.05). AOFAS scores were similar, with the standard TAA group scoring 83.33 +/- 7.55 and the PSI group scoring 82.92 +/- 9.7 (p = 0.870). Likewise, the postoperative ROM did not differ significantly, with 15.12 +/- 7.6 degrees for the standard TAA group and 16.05 +/- 6.7 degrees for the PSI group (p = 0.689). However, the standard TAA group experienced significantly longer operative time (107.1 +/- 22.1 min) compared to the PSI group (91.92 +/- 22.9 min, p = 0.032). Additionally, the standard TAA group required more adjunctive procedures (29.7%) compared to the PSI group (7.7%, p = 0.04). Residual pain was also more frequently reported in the standard TAA group (62.7%) than in the PSI group (30.7%, p = 0.038). Conclusion: While both techniques resulted in comparable complication rates, clinical scores and ROM, the PSI group reported significantly shorter operative time and less residual pain, thus requiring fewer postoperative procedures.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial
    Kosse, Nienke M.
    Heesterbeek, Petra J. C.
    Schimmel, Janneke J. P.
    van Hellemondt, Gijs G.
    Wymenga, Ate B.
    Defoort, Koen C.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) : 1792 - 1799
  • [42] 3D-printed patient-specific instrumentation decreases the variability of patellar height in total knee arthroplasty
    Wang, Junfeng
    Wang, Xiaohua
    Sun, Bin
    Yuan, Liang
    Zhang, Ke
    Yang, Bin
    FRONTIERS IN SURGERY, 2023, 9
  • [43] CT-based patient-specific instrumentation for total knee arthroplasty in over 700 cases: single-use instruments are as accurate as standard instruments
    Gaukel, Stefan
    Vuille-dit-Bille, Raphael N.
    Schlappi, Michel
    Koch, Peter P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (02) : 447 - 455
  • [44] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Jerry Yongqiang Chen
    Seng Jin Yeo
    Andy Khye Soon Yew
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Pak Lin Chin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 630 - 635
  • [45] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1705 - 1708
  • [46] Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
    Parratte, Sebastien
    Blanc, Guillaume
    Boussemart, Thomas
    Ollivier, Matthieu
    Le Corroller, Thomas
    Argenson, Jean-Noel
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2213 - 2219
  • [47] Should we abandon the patient-specific instrumentation ship in total knee arthroplasty? Not quite yet!
    Torok, Laszlo
    Javor, Peter
    Hartmann, Petra
    Banki, Laszlo
    Varga, Endre
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [48] Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty
    Lustig, Sebastien
    Scholes, Corey J.
    Oussedik, Sam I.
    Kinzel, Vera
    Coolican, Myles R. J.
    Parker, David A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 469 - 473
  • [49] Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
    Sébastien Parratte
    Guillaume Blanc
    Thomas Boussemart
    Matthieu Ollivier
    Thomas Le Corroller
    Jean-Noël Argenson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2213 - 2219
  • [50] Patient-specific instrumentation technology enhances clinical outcomes in total elbow arthroplasty
    Zhang, Changgui
    Heng, Hongquan
    Deng, Shu
    Chen, Xin
    Chen, Guangxing
    Chen, Hao
    BMC SURGERY, 2025, 25 (01)