Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study

被引:1
|
作者
Arceri, Alberto [1 ]
Abdi, Pejman [1 ]
Mazzotti, Antonio [1 ,2 ]
Zielli, Simone Ottavio [1 ]
Artioli, Elena [1 ]
Langone, Laura [1 ]
Sgubbi, Federico [1 ]
Faldini, Cesare [1 ,2 ]
机构
[1] Ist Ortoped Rizzoli, Ist Ricovero & Cura Carattere Sci IRCCS, Orthopaed & Traumatol Clin 1, I-40136 Bologna, Italy
[2] Alma Mater Studiorum Univ Bologna, Dept Biomed & Neuromotor Sci DIBINEM, Bologna, Italy
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 07期
关键词
total ankle arthroplasty; patient-specific instrumentation; surgical outcomes; retrospective analysis; complications; REPLACEMENT; DEFORMITY; OUTCOMES; MOTION; RANGE; VARUS;
D O I
10.3390/jpm14070770
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: This retrospective study aims to compare surgical outcomes between two cohorts of patients who underwent total ankle arthroplasty (TAA) using either standard technique or patient-specific instrumentation (PSI). Methods: A consecutive series of patients who affected of end-staged ankle osteoarthritis were retrospectively assessed and divided into two groups based on TAA techniques: a TAA standard technique group and a TAA-using PSI group. The two groups were compared in terms of operative time, additional procedures, complications (neurovascular and wound problems, infection, loosening and osteolysis, revision and explantation rates, and perioperative fracture), clinical scores, and range of motion (ROM). Result: Fifty-one patients underwent standard TAA, while 13 patients underwent TAA with PSI. At 1-year follow-up, there were no significant differences in complication rates between the two groups (p > 0.05). AOFAS scores were similar, with the standard TAA group scoring 83.33 +/- 7.55 and the PSI group scoring 82.92 +/- 9.7 (p = 0.870). Likewise, the postoperative ROM did not differ significantly, with 15.12 +/- 7.6 degrees for the standard TAA group and 16.05 +/- 6.7 degrees for the PSI group (p = 0.689). However, the standard TAA group experienced significantly longer operative time (107.1 +/- 22.1 min) compared to the PSI group (91.92 +/- 22.9 min, p = 0.032). Additionally, the standard TAA group required more adjunctive procedures (29.7%) compared to the PSI group (7.7%, p = 0.04). Residual pain was also more frequently reported in the standard TAA group (62.7%) than in the PSI group (30.7%, p = 0.038). Conclusion: While both techniques resulted in comparable complication rates, clinical scores and ROM, the PSI group reported significantly shorter operative time and less residual pain, thus requiring fewer postoperative procedures.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty
    Chan, Warwick Chun-Wang
    Pinder, Elizabeth
    Loeffler, Mark
    JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (02) : 175 - 178
  • [22] Accuracy of CT-Derived Patient-Specific Instrumentation for Total Ankle Arthroplasty: The Impact of the Severity of Preoperative Varus Ankle Deformity
    Umbel, Benjamin D. D.
    Hockman, Taylor
    Myers, Devon
    Sharpe, B. Dale
    Berlet, Gregory C. C.
    FOOT & ANKLE SPECIALIST, 2023, 16 (03) : 205 - 213
  • [23] Effectiveness and Accuracy of a Patient-Specific Instrumentation System for Total Hip Arthroplasty
    Zhang, Teng
    Jia, Zhao
    Han, Wei
    Wang, Junqiang
    Li, Jinqi
    Gong, Maoqi
    Jiang, Xieyuan
    ORTHOPAEDIC SURGERY, 2023, 15 (03) : 878 - 887
  • [24] Patient-specific instrumentation for total shoulder arthroplasty: not as accurate as it would seem
    Lau, Simon C.
    Keith, Prue P. A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (01) : 90 - 95
  • [25] Conversion of Symptomatic Ankle Arthrodesis Nonunion to Total Ankle Arthroplasty Using Patient-specific Instrumentation and Computer-assisted Surgery Guides: A Case Report
    Iturregui, Jose M.
    Haupt, Edward T.
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2023, 22 (02): : 99 - 109
  • [26] Patient-Specific Instrumentation Does Not Improve Alignment in Total Knee Arthroplasty
    Russell, Robert
    Brown, Timothy
    Huo, Michael
    Jones, Richard
    JOURNAL OF KNEE SURGERY, 2014, 27 (06) : 501 - 504
  • [27] Patient-specific instrumentation for total knee arthroplasty: a literature review
    Camarda L.
    D’Arienzo A.
    Morello S.
    Peri G.
    Valentino B.
    D’Arienzo M.
    MUSCULOSKELETAL SURGERY, 2015, 99 (1) : 11 - 18
  • [28] Accuracy of Patient-Specific Instrumentation Compared With Conventional Instrumentation in Total Knee Arthroplasty
    Jiang, Jin
    Kang, Xin
    Lin, Qiao
    Teng, Yuanjun
    An, Liping
    Ma, Jingling
    Wang, Jing
    Xia, Yayi
    ORTHOPEDICS, 2015, 38 (04) : E305 - E313
  • [29] Custom-made total ankle arthroplasty with patient-specific instrumentation for severe bone loss conditions: a case series
    Cesare Faldini
    Antonio Mazzotti
    Laura Langone
    Alberto Arceri
    Simone Bonelli
    Simone Ottavio Zielli
    Elena Artioli
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 379 - 387
  • [30] Custom-made total ankle arthroplasty with patient-specific instrumentation for severe bone loss conditions: a case series
    Faldini, Cesare
    Mazzotti, Antonio
    Langone, Laura
    Arceri, Alberto
    Bonelli, Simone
    Zielli, Simone Ottavio
    Artioli, Elena
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01) : 379 - 387