Standardization and optimization of Siemens Biograph TruePoint PET/CT acquisition and reconstruction parameters: Simultaneous qualitative and quantitative assessments

被引:0
作者
Vosoughi, Habibeh [1 ,2 ]
Emami, Farshad [3 ]
Momennezhad, Mehdi [4 ]
Geramifar, Parham [2 ]
Rahmim, Arman [5 ,6 ]
机构
[1] Mashhad Univ Med Sci, Dept Med Phys, Mashhad, Iran
[2] Univ Tehran Med Sci, Res Ctr Nucl Med, Tehran, Iran
[3] Imam Reza Int Univ, Razavi Hosp, Nucl Med & Mol Imaging Dept, Mashhad, Iran
[4] Mashhad Univ Med Sci, Fac Med, Nucl Med Res Ctr, Mashhad, Iran
[5] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[6] Univ British Columbia, Dept Phys, Vancouver, BC, Canada
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2024年 / 32卷 / 02期
关键词
POINT-SPREAD-FUNCTION; TIME-OF-FLIGHT; IMAGE QUALITY; F-18-FDG PET/CT; IMPACT; QUANTIFICATION; ACCURACY;
D O I
10.22034/IRJNM.2024.129432.1579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Data acquisition and image reconstruction protocols affect image quality and quantification accuracy in PET imaging. We aimed to standardize and optimize image acquisition, and reconstruction parameter sets using a simultaneous quantitative and qualitative assessment framework for a lutetium oxyorthosilicate (LSO)-based PET/CT scanner. Methods: The NEMA IEC Body Phantom acquisition was performed in list mode for 10 minutes with four spheres to background ratios (SBRs). Raw PET data were reconstructed using 60 different protocols. Image quality was evaluated for standardization using contrast, CNR, and noise. Recovery coefficient (RC) measurements were performed for different common VOI definitions. Results: No significant differences were observed between RCs for various acquisition durations. The contrast to noise ratio (CNR) increased at all SBRs by expanding the acquisition duration from 60 to 600 seconds. PET scan time was reduced to 90 seconds per bed position while preserving image quality. Up to 50% improvement in CNR for the highest sub-iteration with a high level of smoothing was observed. PSF-based reconstruction produced a positive bias of RC max in high SBRs (8 and 10) using higher sub-iterations (30 to 60) with Gaussian filters less than 6 mm FWHM. Moreover, a Sub-iteration of more than 32 with a 4-6 mm FWHM Gaussian filter provides optimized reconstruction sets. Conclusion: Our study demonstrates it would be feasible for PET image acquisition and reconstruction settings to simultaneously allow optimal lesion detection with high image quality while providing accurate quantification.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 30 条
  • [1] A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
    Adams, Michael C.
    Turkington, Timothy G.
    Wilson, Joshua M.
    Wong, Terence Z.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) : 310 - 320
  • [2] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [3] Bai B, 2010, IEEE NUCL SCI CONF R, P2263, DOI 10.1109/NSSMIC.2010.5874186
  • [4] PET quantification: Strategies for partial volume correction
    Bettinardi V.
    Castiglioni I.
    De Bernardi E.
    Gilardi M.C.
    [J]. Clinical and Translational Imaging, 2014, 2 (3) : 199 - 218
  • [5] FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
    Boellaard, Ronald
    Delgado-Bolton, Roberto
    Oyen, Wim J. G.
    Giammarile, Francesco
    Tatsch, Klaus
    Eschner, Wolfgang
    Verzijlbergen, Fred J.
    Barrington, Sally F.
    Pike, Lucy C.
    Weber, Wolfgang A.
    Stroobants, Sigrid
    Delbeke, Dominique
    Donohoe, Kevin J.
    Holbrook, Scott
    Graham, Michael M.
    Testanera, Giorgio
    Hoekstra, Otto S.
    Zijlstra, Josee
    Visser, Eric
    Hoekstra, Corneline J.
    Pruim, Jan
    Willemsen, Antoon
    Arends, Bertjan
    Kotzerke, Joerg
    Bockisch, Andreas
    Beyer, Thomas
    Chiti, Arturo
    Krause, Bernd J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (02) : 328 - 354
  • [6] FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
    Boellaard, Ronald
    O'Doherty, Mike J.
    Weber, Wolfgang A.
    Mottaghy, Felix M.
    Lonsdale, Markus N.
    Stroobants, Sigrid G.
    Oyen, Wim J. G.
    Kotzerke, Joerg
    Hoekstra, Otto S.
    Pruim, Jan
    Marsden, Paul K.
    Tatsch, Klaus
    Hoekstra, Corneline J.
    Visser, Eric P.
    Arends, Bertjan
    Verzijlbergen, Fred J.
    Zijlstra, Josee M.
    Comans, Emile F. I.
    Lammertsma, Adriaan A.
    Paans, Anne M.
    Willemsen, Antoon T.
    Beyer, Thomas
    Bockisch, Andreas
    Schaefer-Prokop, Cornelia
    Delbeke, Dominique
    Baum, Richard P.
    Chiti, Arturo
    Krause, Bernd J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) : 181 - 200
  • [7] Standards for PET Image Acquisition and Quantitative Data Analysis
    Boellaard, Ronald
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 11S - 20S
  • [8] Investigation of 18F-FDG 3D mode PET image quality versus acquisition time
    Brown, Colin
    Dempsey, Mary-Frances
    Gillen, Gerry
    Elliott, Alex T.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (03) : 254 - 259
  • [9] Delbeke D, 2006, J NUCL MED, V47, P885
  • [10] Impact of PET reconstruction protocols on quantification of lesions that fulfil the PERCIST lesion inclusion criteria
    Devriese, Joke
    Beels, Laurence
    Maes, Alex
    Van de Wiele, Christophe
    Pottel, Hans
    [J]. EJNMMI PHYSICS, 2018, 5