Experimental assessment of the exposure to airborne exhaled contaminants using general and personalised ventilation systems in a hospital room

被引:4
作者
Sanchez-Jimenez, J. L. [1 ]
Peci, F. [1 ]
de Adana, M. Ruiz [1 ]
机构
[1] Cordoba Univ, Dept Chem Phys & Appl Thermodynam, Cordoba 14014, Spain
关键词
Hospital environments; Ventilation; Personalised ventilation systems; Exhaled contaminants; THERMAL MANNEQUINS; AIR-FLOW; PERFORMANCE; DISPERSION; COMFORT;
D O I
10.1016/j.buildenv.2024.111419
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ensuring good indoor air quality is critical in hospitals. An environment free from airborne particles can prevent the spread of various diseases and improve patient health. In this study, the efficiency of a personalised ventilation supply system (PSS) and personalised ventilation extraction system (PES) for diluting and removing contaminants exhaled by a patient in a hospital bed was evaluated. These systems, which were integrated into the head and foot of a hospital bed, were combined with three general ventilation strategies in the room. Fifteen ventilation strategies were analysed experimentally. Two breathing thermal manikins (BTMs) were used to simulate a patient and health worker in a hospital. The breathing of each BTM was controlled by the patient (source) generating particles that can increase the risk of infection in a healthy person (target). Experimental results show that using a PES combined with general ventilation of the room reduces the exposure of the target manikin compared to general ventilation strategies alone. However, no marked improvement was observed when the PSS was activated. The reduction in exposure to the target manikin was considerable when the PES was located at the foot of the hospital bed, which is the preferred option for integrating personalised systems in a hospital bed.
引用
收藏
页数:12
相关论文
共 35 条
  • [1] Natural Personalised Ventilation - A Novel Approach
    Adamu, Z. A.
    Cook, M. J.
    Price, A. D. F.
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2011, 10 (03) : 263 - 275
  • [2] An experimental study on the effects of positioning medical equipment on contaminant exposure of a patient in an operating room with unidirectional downflow
    Aganovic, Amar
    Cao, Guangyu
    Stenstad, Liv-Inger
    Skogas, Jan G.
    [J]. BUILDING AND ENVIRONMENT, 2019, 165
  • [3] [Anonymous], 2011, I.A.Q. Applications, Melikov_2011_Advanced Air Distribution, P73
  • [4] Experimental assessment of different mixing air ventilation systems on ventilation performance and exposure to exhaled contaminants in hospital rooms
    Berlanga, F. A.
    Olmedo, I.
    Ruiz de Adana, M.
    Villafruela, J. M.
    San Jose, J. F.
    Castro, F.
    [J]. ENERGY AND BUILDINGS, 2018, 177 : 207 - 219
  • [5] Experimental evaluation of thermal comfort, ventilation performance indices and exposure to airborne contaminant in an airborne infection isolation room equipped with a displacement air distribution system
    Berlanga, F. A.
    Ruiz de Adana, M.
    Olmedo, I.
    Villafruela, J. M.
    San Jose, J. F.
    Castro, F.
    [J]. ENERGY AND BUILDINGS, 2018, 158 : 209 - 221
  • [6] Experimental analysis of the air velocity and contaminant dispersion of human exhalation flows
    Berlanga, F. A.
    Olmedo, I.
    Ruiz de Adana, M.
    [J]. INDOOR AIR, 2017, 27 (04) : 803 - 815
  • [7] A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects
    Bivolarova, M.
    Ondracek, J.
    Melikov, A.
    Zdimal, V.
    [J]. INDOOR AIR, 2017, 27 (06) : 1201 - 1212
  • [8] Bivolarova M.P., 2014, 1IN P ROOMVENT 2014, P49
  • [9] Bed-integrated local exhaust ventilation system combined with local air cleaning for improved IAQ in hospital patient rooms
    Bivolarova, Mariya P.
    Melikov, Arsen K.
    Mizutani, Chiyomi
    Kajiwara, Kanji
    Bolashikov, Zhecho D.
    [J]. BUILDING AND ENVIRONMENT, 2016, 100 : 10 - 18
  • [10] Characterizing exhaled airflow from breathing and talking
    Gupta, Jitendra K.
    Lin, Chao-Hsin
    Chen, Qingyan
    [J]. INDOOR AIR, 2010, 20 (01) : 31 - 39