Mitigation of Low Harmonic Ripples Based on the Three-Phase Dual Active Bridge Converter in Charging Station Applications

被引:1
|
作者
Goto, Takuya [1 ]
Pham, The-Tiep [2 ,3 ]
Nguyen, Nam-Danh [2 ]
Yukita, Kazuto [1 ]
Nguyen, Duy-Dinh [2 ]
机构
[1] Aichi Inst Technol, Dept Elect Engn, Yachigusa 1247 Yakusacho, Toyota, Aichi 4700356, Japan
[2] Hanoi Univ Sci & Technol, Sch Elect & Elect Engn, Hanoi 100000, Vietnam
[3] EVSELab Co Ltd, Hanoi 100000, Vietnam
关键词
three-phase dual active bridge (DAB3) converter; low frequency harmonics; CHAdeMO standard; DC-DC CONVERTER; POWER; TRANSFORMER; SYSTEM;
D O I
10.3390/electronics13132527
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To minimize the recharge time of EVs, Level 3 charging stations utilizing DC fast charging systems have become increasingly prevalent. Additionally, these systems offer bidirectional functionality, aiding in stabilizing the DC grid during peak hour. As a result, the DC-DC converters utilized in such systems must be capable of bidirectional energy transfer. Among existing typologies, DAB converters are preferred due to their simplicity and sustainability. The three-phase DAB (DAB3) is favored because the output ripple is lower compared to the single-phase structure. This characteristic assists in mitigating the negative effects on the battery caused by high-frequency current ripple. However, the input to DAB3 converters typically originates from AC-DC stages, leading to the inclusion of low harmonic frequency ripples (e.g., multiples of 360 Hz). These ripples are then transferred to the battery, increasing its temperature. To address this issue, this paper proposes a technique to mitigate negative effects by attenuating these low frequencies in the charging current. Simulations were conducted to demonstrate the effectiveness of the proposed technique. Scaled-down experiments utilizing a DAB3 prototype were conducted to corroborate the simulations. The findings demonstrated a reduction in ripple from 8.66% to below 2.67% when compared to the original controller. This reduction enabled the solution to meet the limiting current ripple criteria outlined in the CHAdeMO standard.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] A Three-Phase Asymmetrical Dual-Active-Bridge Converter With Series/Parallel-Reconfigurable Output for Wide Voltage Range Applications
    Shen, Chong
    Wu, Hongfei
    Liu, Tao
    Li, Mengxi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (09) : 7714 - 7724
  • [42] Analysis of Dual Active Bridge based Power Electronic Transformer as a Three-phase Inverter
    Moonem, M. A.
    Krishnaswami, H.
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 238 - 243
  • [43] Triple Active Bridge Series Resonant Converter for three-Phase Unfolding Based Isolated Converters
    Yelaverthi, Dorai Babu
    Mansour, Mahmoud
    Wang, Hongjie
    Zane, Regan
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 4924 - 4930
  • [44] Measurement-Based Harmonic Modeling of an Electric Vehicle Charging Station Using a Three-Phase Uncontrolled Rectifier
    Zhou, Niancheng
    Wang, Jiajia
    Wang, Qianggang
    Wei, Nengqiao
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (03) : 1332 - 1340
  • [45] Comparative Analysis of Single and Three-phase Dual Active Bridge Bidirectional DC-DC Converter Based on the Phase-Shifting Control
    Yan, Gangui
    Li, Yonglin
    Jia, Qi
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ELECTRICAL ENGINEERING, 2016, 56 : 326 - 333
  • [46] Modeling and Dynamic Control of a Three-Phase Dual-Active Bridge Converter Using a Hybrid Modulation Scheme
    Hu, Jingxin
    Yang, Zhiqing
    Averous, Nurhan Rizqy
    De Doncker, Rik W.
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 6291 - 6298
  • [47] An Analytical Modeling and Estimating Losses of Power Semiconductors in a Three-Phase Dual Active Bridge Converter for MVDC Grids
    Lee, Youngsil
    Vakil, Gaurang
    Watson, Alan. J.
    Wheeler, Patrick W.
    2017 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2017,
  • [48] Modelling and compensation of dead time in three-phase dual-active bridge DC-DC converter
    Siddique, Hafiz Abu Bakar
    Joebges, Philipp
    De Doncker, Rik W.
    EPE JOURNAL, 2020, 30 (03) : 122 - 138
  • [49] DC Fault Ride-Through of a Three-Phase Dual-Active Bridge Converter for DC Grids
    Hu, Jingxin
    Cui, Shenghui
    De Doncker, Rik W.
    2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 2250 - 2256
  • [50] Enhanced Modulation Strategy for a Three-Phase Dual Active Bridge-Boosting Efficiency of an Electric Vehicle Converter
    van Hoek, Hauke
    Neubert, Markus
    De Doncker, Rik W.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (12) : 5499 - 5507