BREAKAGES OF SODERBERG ELECTRODES DURING SUBMERGED ARC FURNACES START-UP

被引:0
|
作者
Kozlowski, Slawomir [1 ]
Koltun, Konrad [2 ]
Janik, Katarzyna [2 ]
Banasik, Lukasz [2 ]
机构
[1] Silesian Tech Univ, Katowice, Poland
[2] Re Alloys sp zoo, Laziska Gorne, Poland
关键词
Metallurgy; self-baking electrode; submerged arc furnaces; ferrosilicon;
D O I
10.37904/metal.2023.4676
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
This article presents a technological issue related to the operation of self-baking electrodes in six-electrodes submerged arc furnaces during the process of smelting high-grade silicon alloys with iron and other elements by carbothermal reduction, carried out in Re Alloys ferroalloys plant. Particular attention is paid to technological problems related to the use of Soderberg electrodes during start-ups of electric furnaces after shutdowns. The impact of furnace shutdowns and starts-ups on thermal conditions disturbance of electrode sintering process, formation of microcracks, and thus deterioration of mechanical strength of the electrode leading to increased risk of breaking, is presented. Actual examples of electrode breaking during SAF start-up, causes of breaking, and possible ways to avoid them are described in the article.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [31] Nitrifying biofilm acclimation to free ammonia in submerged biofilters.: Start-up influence
    Villaverde, S
    Fdz-Polanco, F
    García, PA
    WATER RESEARCH, 2000, 34 (02) : 602 - 610
  • [32] Decrease in the Consumption of Graphitized Electrodes in Arc Furnaces during Their Forced Cooling
    Yachikov, I. M.
    Kolokol'tsev, V. M.
    RUSSIAN METALLURGY, 2009, 2009 (07): : 622 - 624
  • [33] Effects of Stepwise Adjustment of C/N during the Start-Up of Submerged Membrane Bioreactors (SMBRs) on the Aerobic Denitrification of Wastewater
    Zhang, Yinan
    Fang, Yuxin
    Wang, Banglong
    Zhang, Hangjun
    Ding, Jiafeng
    WATER, 2021, 13 (22)
  • [34] START-UP OF 150-TON ELECTRIC ARC FURNACE AT LUKENS.
    Pongia, Vincent J.
    Iron and Steel Engineer, 1975, 52 (12): : 36 - 44
  • [35] Simulation of load amplification during start-up of gear compressors
    Althaus, J
    INTERNATIONAL CONFERENCE ON GEARS, 1996, 1230 : 175 - 186
  • [36] The effect of current density on cathode expansion during start-up
    Ratvik, Arne Petter
    Store, Anne
    Solheim, Asbjorn
    Foosnaes, Trygve
    LIGHT METALS 2008, 2008, : 973 - +
  • [37] LOOP VOLTAGE AND MHD ACTIVITY DURING THE START-UP OF AN RFP
    DRAKE, JR
    BRZOZOWSKI, J
    MAZUR, S
    NORDLUND, P
    PHYSICA SCRIPTA, 1994, 49 (02): : 224 - 227
  • [38] Loop voltage and MHD activity during the start-up of an RFP
    Drake, J.R.
    Brzozowski, J.
    Mazur, S.
    Nordlund, P.
    Physica Scripta, 1994, 49 (02) : 224 - 227
  • [39] An analysis of reactivity prediction during the reactor start-up process
    Bajgl, J.
    Krysl, V.
    Svarny, J.
    KERNTECHNIK, 2015, 80 (04) : 339 - 348
  • [40] ANALYSIS OF INDUCTION-MOTOR VIBRATION DURING START-UP
    ZUBRENKOV, BI
    KAPLIN, AI
    MALYSHEV, VS
    MANYUKOV, MF
    ELECTRICAL TECHNOLOGY, 1990, (04): : 87 - 94