Plastic hinge length in reinforced HPFRCC beams and columns

被引:2
|
作者
Almeida, Joseph A. [1 ]
Bandelt, Matthew J. [1 ]
机构
[1] New Jersey Inst Technol, John A Reify Jr Dept Civil & Environm Engn, 323 Dr Martin Luther King Jr Blvd, Newark, NJ 07102 USA
基金
美国国家科学基金会;
关键词
Plastic hinge length; Rotation capacity; HPFRCC; UHPC; ECC; Axial load; Column; Beam; HIGH-PERFORMANCE CONCRETE; FLEXURAL MEMBERS; BEHAVIOR; COMPOSITES; DUCTILITY; SHEAR;
D O I
10.1016/j.engstruct.2024.118345
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of ductile concrete materials such as High Performance Fiber Reinforced Cementitious Composites (HPFRCCs) within plastic hinge regions of structural components has garnered research interest in order to improve the seismic resistance of reinforced concrete structures. While experimental and numerical results appear promising in reducing component damage and probability of system level collapse, accurate nonlinear analysis tools capable of capturing the influence of axial load well into a component's inelastic regime is needed. In this study, a series of 180 high fidelity numerical simulations of HPFRCC beam-column elements are simulated and used to calibrate new plastic hinge length expressions for concentrated and distributed plasticity models for use in system level structural analysis. The numerical models cover a range of HPFRCC material properties, reinforcement ratios, shear span lengths, and axial load levels. The ability of the newly developed expressions to predict component inelastic rotations are subsequently compared to hinge length expressions in the literature and the inelastic rotations of 47 experimental components. The results of this study provide new insights into the effects of axial load on the plastic hinge behavior of HPFRCC components, significantly improves on the accuracy of past plastic hinge length expressions allowing for more accurate modeling of HPFRCC component responses and system level behavior.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Plastic Hinge Rotation Capacity of Reinforced HPFRCC Beams
    Hemmati, Ali
    Kheyroddin, Ali
    Sharbatdar, Mohammad Kazem
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (02)
  • [2] Plastic hinge length of reinforced concrete columns
    Bae, Sungjin
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2008, 105 (03) : 290 - 300
  • [3] Plastic Hinge Length of Reinforced Concrete Columns Discussion
    Subramanian, N.
    Elmenshawi, Abdelsamie
    ACI STRUCTURAL JOURNAL, 2009, 106 (02) : 233 - 237
  • [4] Assessment of plastic hinge length in reinforced concrete columns
    Pham, Phu-Anh-Huy
    Hung, Chung-Chan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2023,
  • [5] Plastic hinge length of circular reinforced concrete columns
    Ou, Yu-Chen
    Kurniawan, Raditya Andy
    Kurniawan, Dimas Pramudya
    Nguyen Dang Nguyen
    COMPUTERS AND CONCRETE, 2012, 10 (06): : 663 - 681
  • [6] Plastic Hinge Length of Corroded Reinforced Concrete Beams
    Ou, Yu-Chen
    Nguyen Dang Nguyen
    ACI STRUCTURAL JOURNAL, 2014, 111 (05) : 1049 - 1057
  • [7] Equivalent plastic hinge length of circular reinforced concrete bridge columns
    1600, Chinese Society of Civil Engineering (49):
  • [8] Probabilistic Approach for Estimating Plastic Hinge Length of Reinforced Concrete Columns
    Ning, Chao-Lie
    Li, Bing
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [9] Calculation method of equivalent plastic hinge length of corroded reinforced concrete columns
    Zheng Y.
    Zheng S.
    Dong L.
    Zhang Y.
    Yang S.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2021, 52 (12): : 4424 - 4433
  • [10] A novel formula for plastic hinge length of reinforced concrete columns in seismic regions
    Wei, Wang
    Shao, Changjiang
    Huang, Hui
    Zhuang, Weilin
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024, 20 (10) : 1484 - 1499