Finite element analysis of patient-specific additive-manufactured implants

被引:0
作者
Namvar, Arman [1 ,2 ]
Lozanovski, Bill [1 ]
Downing, David [1 ]
Williamson, Tom [1 ,3 ]
Kastrati, Endri [1 ,3 ]
Shidid, Darpan [1 ]
Hill, David [1 ]
Buehner, Ulrich [3 ]
Ryan, Stewart [4 ]
Choong, Peter F. [2 ]
Sanaei, Reza [4 ]
Leary, Martin [1 ]
Brandt, Milan [1 ]
机构
[1] RMIT Univ, RMIT Ctr Addit Manufacture, Sch Engn, Melbourne, Vic, Australia
[2] St Vincents Hosp, Dept Surg, Melbourne, Vic, Australia
[3] Stryker, Sydney, NSW, Australia
[4] Univ Melbourne, Melbourne Vet Sch, Fac Sci, Melbourne, Vic, Australia
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
bone tumors; patient-specific implants; endoprosthetic reconstruction; biomechanical testing; additive manufacturing; femur; LATTICE STRUCTURES; STRENGTH;
D O I
10.3389/fbioe.2024.1386816
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Bone tumors, characterized by diverse locations and shapes, often necessitate surgical excision followed by custom implant placement to facilitate targeted bone reconstruction. Leveraging additive manufacturing, patient-specific implants can be precisely tailored with complex geometries and desired stiffness, enhancing their suitability for bone ingrowth.Methods: In this work, a finite element model is employed to assess patient-specific lattice implants in femur bones. Our model is validated using experimental data obtained from an animal study (n = 9).Results: The results demonstrate the accuracy of the proposed finite element model in predicting the implant mechanical behavior. The model was used to investigate the influence of reducing the elastic modulus of a solid Ti6Al4V implant by tenfold, revealing that such a reduction had no significant impact on bone behavior under maximum compression and torsion loading. This finding suggests a potential avenue for reducing the endoprosthesis modulus without compromising bone integrity.Discussion: Our research suggests that employing fully lattice implants not only facilitates bone ingrowth but also has the potential to reduce overall implant stiffness. This reduction is crucial in preventing significant bone remodeling associated with stress shielding, a challenge often associated with the high stiffness of fully solid implants. The study highlights the mechanical benefits of utilizing lattice structures in implant design for enhanced patient outcomes.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Properties of Additive-Manufactured Open Porous Titanium Structures for Patient-Specific Load-Bearing Implants
    Zumofen, Livia
    Kopanska, Katarzyna S.
    Bono, Epifania
    Kirchheim, Andreas
    De Haller, Emmanuel B.
    Graf-Hausner, Ursula
    FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2022, 7
  • [2] Patient-specific finite element analysis of femurs with cemented hip implants
    Katz, Yekutiel
    Lubovsky, Omri
    Yosibash, Zohar
    CLINICAL BIOMECHANICS, 2018, 58 : 74 - 89
  • [3] Artificial Neural Network-Based Predictive Model for Finite Element Analysis of Additive-Manufactured Components
    Grozav, Sorin D.
    Sterca, Alexandru D.
    Kocisko, Marek
    Pollak, Martin
    Ceclan, Vasile
    MACHINES, 2023, 11 (05)
  • [4] Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area
    Mitsuru Takemoto
    Shunsuke Fujibayashi
    Eigo Ota
    Bungo Otsuki
    Hiroaki Kimura
    Takeshi Sakamoto
    Toshiyuki Kawai
    Tohru Futami
    Kiyoyuki Sasaki
    Tomiharu Matsushita
    Takashi Nakamura
    Masashi Neo
    Shuich Matsuda
    European Spine Journal, 2016, 25 : 1698 - 1705
  • [5] Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area
    Takemoto, Mitsuru
    Fujibayashi, Shunsuke
    Ota, Eigo
    Otsuki, Bungo
    Kimura, Hiroaki
    Sakamoto, Takeshi
    Kawai, Toshiyuki
    Futami, Tohru
    Sasaki, Kiyoyuki
    Matsushita, Tomiharu
    Nakamura, Takashi
    Neo, Masashi
    Matsuda, Shuich
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1698 - 1705
  • [6] Just-in-time design and additive manufacture of patient-specific medical implants
    Shidid, Darpan
    Leary, Martin
    Choong, Peter
    Brandt, Milan
    LASER ASSISTED NET SHAPE ENGINEERING 9 INTERNATIONAL CONFERENCE ON PHOTONIC TECHNOLOGIES PROCEEDINGS OF THE LANE 2016, 2016, 83 : 4 - 14
  • [7] An additively manufactured locking fixation system for potential application in patient-specific implants
    Fischer, Ralf D.
    Klasen, Jan
    Shmatok, Andrii
    Prorok, Barton C.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124 (124)
  • [8] Patient-Specific Orthopaedic Implants
    Haglin, Jack M.
    Eltorai, Adam E. M.
    Gil, Joseph A.
    Marcaccio, Stephen E.
    Botero-Hincapie, Juliana
    Daniels, Alan H.
    ORTHOPAEDIC SURGERY, 2016, 8 (04) : 417 - 424
  • [9] Development of 18 Quality Control Gates for Additive Manufacturing of Error Free Patient-Specific Implants
    Martinez-Marquez, Daniel
    Jokymaityte, Milda
    Mirnajafizadeh, Ali
    Carty, Christopher P.
    Lloyd, David
    Stewart, Rodney A.
    MATERIALS, 2019, 12 (19)
  • [10] Patient-specific finite element analysis of the human femur-A double-blinded biomechanical validation
    Trabelsi, Nir
    Yosibash, Zohar
    Wutte, Christof
    Augat, Peter
    Eberle, Sebastian
    JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1666 - 1672