Somatosensory alterations after single-unit dental implant immediate loading: A 1-year follow-up study

被引:0
|
作者
Herreira-Ferreira, Matheus [1 ]
Bonfante, Estevam Augusto [2 ]
Conti, Pauloesar Rodrigues [2 ]
Araujo-Junior, Everardo Napolea Santana de [2 ]
Machado, Camila Moreira [2 ]
Alves, Patrick Henry Machado [2 ]
Costa, Yuri Martins [3 ]
Bonjardim, Leonardo Rigoldi [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Biol Sci, Bauru, Brazil
[2] Univ Sao Paulo, Bauru Sch Dent, Dept Prosthodont & Periodontol, Bauru, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Biosci, Piracicaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Single; -tooth; Immediate dental implant loading; Somatosensory Disorders; QUALITY-OF-LIFE; HEALED ALVEOLAR RIDGES; PLACEMENT; MULTICENTER; SURVIVAL; PAIN;
D O I
10.1016/j.jdent.2024.105148
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This cohort study aimed to assess the incidence of somatosensory alterations after implant surgery using standardized quantitative and qualitative sensory testing. Methods: 33 participants with single-tooth loss, undergoing immediate implant loading were included. Quantitative Sensory Testing (QST) and Qualitative Sensory Testing (QualST) were conducted at eight time points over a year (baseline to 1 year). Two-Way Repeated Measures ANOVA and post hoc Tukey test were used on QST values and Cochran Q test on QualST. Results: The study revealed significant increase in thermal thresholds overtime. At the operated side, overall Cold Pain Threshold (extraoral: p = 0.030; intraoral: p < 0.001), and Cold Detection Threshold (intraoral: p < 0.001) increased overtime. In contralateral region, maxilla Cold Detection Threshold (extraoral: p = 0.024; intraoral: p = 0.031), Warm Detection Threshold (extraoral: p = 0.026; intraoral: p = 0.047) and overall Cold Pain Threshold (extraoral and intraoral: p < 0.001) also increased. QualST showed extraoral pinprick (p = 0.032) and intraoral pinprick (p = 0.000), cold (p = 0.000) and touch (p = 0.002) stimuli abnormalities overtime. Conclusions: Somatosensory alterations after implant surgery were detected in both quantitative and qualitative sensory assessments, but rapidly decreased during the first follow-ups, and then continuously until 1-year.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Psychological Distress After Severe Trauma: A Prospective 1-Year Follow-Up Study of a Trauma Intensive Care Unit Population
    Toien, Kirsti
    Myhren, Hilde
    Bredal, Inger Schou
    Skogstad, Laila
    Sandvik, Leiv
    Ekeberg, Oivind
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (06): : 1552 - 1559
  • [22] Outcomes and Complications of Surgical Treatment for LSS at 1-Year Follow-up - Prospective Study
    Jezek, J.
    Waldauf, P.
    Krbec, M.
    Dousa, P.
    Skala-Rosenbaum, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2019, 86 (04) : 256 - 263
  • [23] Do lifestyle factors influence pain prognosis? A 1-year follow-up study
    Louis, Marc-Henri
    Berquin, Anne
    Steyaert, Arnaud
    BRITISH JOURNAL OF PAIN, 2023, 17 (03) : 293 - 305
  • [24] Round and flat zygomatic implants: effectiveness after a 1-year follow-up non-interventional study
    Aparicio, Carlos
    Polido, Waldemar D.
    Chow, James
    Davo, Ruben
    Al-Nawas, Bilal
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [25] Buccal bone thickness at dental implants in the aesthetic zone: A 1-year follow-up cone beam computed tomography study
    Slagter, Kirsten W.
    Raghoebar, Gerry M.
    Bakker, Nicolaas A.
    Vissink, Arjan
    Meijer, Henny J. A.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (01) : 13 - 19
  • [26] Results at the 1-Year Follow-Up of a Prospective Cohort Study with Short, Zirconia Implants
    Balmer, Marc
    Fischer, Carolin
    Pirc, Miha
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    MATERIALS, 2022, 15 (16)
  • [27] Apathy in subarachnoid hemorrhage: study protocol for a 1-year follow-up study
    Tang, Wai Kwong
    Wong, Kwok Chu George
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [28] Quality of life of stroke survivors: A 1-year follow-up study
    Kwok, Timothy
    Lo, Raymond S.
    Wong, Eric
    Wai-Kwong, Tang
    Mok, Vincent
    Kai-Sing, Wong
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2006, 87 (09): : 1177 - 1182
  • [29] Masticatory ability improves after maxillary implant overdenture treatment: A randomized controlled trial with 1-year follow-up
    Boven, Geessien C.
    Speksnijder, Caroline M.
    Meijer, Henny J. A.
    Vissink, Arjan
    Raghoebar, Gerry M.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (02) : 369 - 376
  • [30] Immediate functional loading of single implants: A 1-year interim report of a 5-year prospective multicentre study
    Luongo, Giuseppe
    Lenzi, Carolina
    Raes, Filiep
    Eccellente, Tammaro
    Ortolani, Michele
    Mangano, Carlo
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (02) : 187 - 199