A parametric study regarding structural design of a bioprosthetic aortic valve by 3D fluid-structure interaction simulations

被引:0
|
作者
Kim, Yongwoo [1 ]
Pyo, Won Kyung [2 ]
Kim, Wan Kee [3 ]
Suh, Ga-Young [4 ]
Kang, Keonwook [1 ]
Lee, Seung Hyun [2 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
[2] Yonsei Univ, Severance Hosp, Coll Med, Dept Thorac Cardiovasc Surg, Seoul, South Korea
[3] Yonsei Univ, Yongin Severance Hosp, Coll Med, Dept Thorac & Cariovasc Surg, Yongin, Gyeonggi Do, South Korea
[4] Calif State Univ Long Beach, Dept Biomed Engn, Long Beach, CA 90840 USA
基金
新加坡国家研究基金会;
关键词
Aortic valve; Fluid-structure interaction; Hemodynamics; Biomechanics; MECHANICAL-PROPERTIES; BOVINE PERICARDIUM; SIZE; REPLACEMENT; COAPTATION; MODEL;
D O I
10.1016/j.heliyon.2024.e27310
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Since the introduction of transcatheter aortic valve (AV) implantation as a viable option, surgical bioprosthetic AVs have recently started incorporating shorter struts considering future valve -invalve procedures. However, the effect of leaflet coaptation geometry on the longevity of these valves remains unexplored. To address this gap, we performed a finite element analysis on bioprosthetic AVs with varying strut heights using a two-way fluid-structure interaction method. To establish a baseline, we used a standard height based on a rendered platform image of the CE PERIMOUNT Magna Ease valve from Edward Lifesciences in Irvine, CA. Bovine pericardium properties were assigned to the leaflets, while normal saline properties were used as the recirculating fluid in hemodynamic simulations. The physiological pressure profile of the cardiac cycle was applied between the aorta and left ventricle. We calculated blood flow velocity, effective orifice area (EOA), and mechanical stress on the leaflets. The results reveal that as the strut height increases, the stroke volume increases, leakage volume decreases, and EOA improves. Additionally, the maximum mechanical stress experienced by the leaflet decreases by 62% as the strut height increases to 1.2 times the standard height. This research highlights that a low-strut design in bioprosthetic AVs may negatively affect their durability, which can be useful in design of nextgeneration bioprosthetic AVs.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Fluid-structure interaction simulation of the three-leaflet aortic valve using COMSOL
    Xu, Xiaoyang
    Cheng, Jie
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [22] 3D fluid-structure interaction with fracturing: A new method with applications
    Dalla Barba, Federico
    Zaccariotto, Mirco
    Galvanetto, Ugo
    Picano, Francesco
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2022, 398
  • [23] Fully coupled dynamic simulations of bioprosthetic aortic valves based on an embedded strategy for fluid-structure interaction with contact
    Nestola, Maria G. C.
    Zulian, Patrick
    Gaedke-Merzhauser, Lisa
    Krause, Rolf
    EUROPACE, 2021, 23 : I96 - I104
  • [24] Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study
    Siguenza, Julien
    Pott, Desiree
    Mendez, Simon
    Sonntag, Simon J.
    Kaufmann, Tim A. S.
    Steinseifer, Ulrich
    Nicoud, Franck
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (04)
  • [25] A Fluid-Structure Interaction Study of Different Bicuspid Aortic Valve Phenotypes Throughout the Cardiac Cycle
    Yan, Wentao
    Li, Jianming
    Wang, Wenshuo
    Wei, Lai
    Wang, Shengzhang
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [26] Simulation Study of Aortic Valve Function Using the Fluid-structure Interaction Finite Element Method
    Sugiura, Seiryo
    Katayama, Susumu
    Umetani, Nobuyuki
    Hisada, Toshiaki
    ADVANCES IN UNDERSTANDING AORTIC DISEASES, 2009, : 53 - 60
  • [27] Fluid-structure interaction analysis of transcatheter aortic valve implantation
    Fumagalli, Ivan
    Polidori, Rebecca
    Renzi, Francesca
    Fusini, Laura
    Quarteroni, Alfio
    Pontone, Gianluca
    Vergara, Christian
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2023, 39 (06)
  • [28] Fluid-Structure Interaction Analysis on the Influence of the Aortic Valve Stent Leaflet Structure in Hemodynamics
    Liu, Xiangkun
    Zhang, Wen
    Ye, Ping
    Luo, Qiyi
    Chang, Zhaohua
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [29] The Comparison of Different Constitutive Laws and Fiber Architectures for the Aortic Valve on Fluid-Structure Interaction Simulation
    Cai, Li
    Zhang, Ruihang
    Li, Yiqiang
    Zhu, Guangyu
    Ma, Xingshuang
    Wang, Yongheng
    Luo, Xiaoyu
    Gao, Hao
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [30] Fluid-structure interaction modeling of aortic valve stenosis at different heart rates
    Bahraseman, Hamidreza Ghasemi
    Languri, Ehsan Mohseni
    Yahyapourjalaly, Niloofar
    Espino, Daniel M.
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2016, 18 (03) : 11 - 20