A parametric study regarding structural design of a bioprosthetic aortic valve by 3D fluid-structure interaction simulations

被引:0
|
作者
Kim, Yongwoo [1 ]
Pyo, Won Kyung [2 ]
Kim, Wan Kee [3 ]
Suh, Ga-Young [4 ]
Kang, Keonwook [1 ]
Lee, Seung Hyun [2 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
[2] Yonsei Univ, Severance Hosp, Coll Med, Dept Thorac Cardiovasc Surg, Seoul, South Korea
[3] Yonsei Univ, Yongin Severance Hosp, Coll Med, Dept Thorac & Cariovasc Surg, Yongin, Gyeonggi Do, South Korea
[4] Calif State Univ Long Beach, Dept Biomed Engn, Long Beach, CA 90840 USA
基金
新加坡国家研究基金会;
关键词
Aortic valve; Fluid-structure interaction; Hemodynamics; Biomechanics; MECHANICAL-PROPERTIES; BOVINE PERICARDIUM; SIZE; REPLACEMENT; COAPTATION; MODEL;
D O I
10.1016/j.heliyon.2024.e27310
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Since the introduction of transcatheter aortic valve (AV) implantation as a viable option, surgical bioprosthetic AVs have recently started incorporating shorter struts considering future valve -invalve procedures. However, the effect of leaflet coaptation geometry on the longevity of these valves remains unexplored. To address this gap, we performed a finite element analysis on bioprosthetic AVs with varying strut heights using a two-way fluid-structure interaction method. To establish a baseline, we used a standard height based on a rendered platform image of the CE PERIMOUNT Magna Ease valve from Edward Lifesciences in Irvine, CA. Bovine pericardium properties were assigned to the leaflets, while normal saline properties were used as the recirculating fluid in hemodynamic simulations. The physiological pressure profile of the cardiac cycle was applied between the aorta and left ventricle. We calculated blood flow velocity, effective orifice area (EOA), and mechanical stress on the leaflets. The results reveal that as the strut height increases, the stroke volume increases, leakage volume decreases, and EOA improves. Additionally, the maximum mechanical stress experienced by the leaflet decreases by 62% as the strut height increases to 1.2 times the standard height. This research highlights that a low-strut design in bioprosthetic AVs may negatively affect their durability, which can be useful in design of nextgeneration bioprosthetic AVs.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A computational study of the three-dimensional fluid-structure interaction of aortic valve
    Chen, Ye
    Luo, Haoxiang
    JOURNAL OF FLUIDS AND STRUCTURES, 2018, 80 : 332 - 349
  • [2] Bioprosthetic Valve Size Selection to Optimize Aortic Valve Replacement Surgical Outcome: A Fluid-Structure Interaction Modeling Study
    Li, Caili
    Tang, Dalin
    Yao, Jing
    Baird, Christopher
    Sun, Haoliang
    Gong, Chanjuan
    Ma, Luyao
    Zhang, Yanjuan
    Wang, Liang
    Yu, Han
    Yang, Chun
    Shao, Yongfeng
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2021, 127 (01): : 159 - 174
  • [3] Analysis of Fluid-Structure Interaction Mechanisms for a Native Aortic Valve, Patient-Specific Ozaki Procedure, and a Bioprosthetic Valve
    Fringand, Tom
    Mace, Loic
    Cheylan, Isabelle
    Lenoir, Marien
    Favier, Julien
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (11) : 3021 - 3036
  • [4] Fluid-structure interaction and structural analyses using a comprehensive mitral valve model with 3D chordal structure
    Toma, Milan
    Einstein, Daniel R.
    Bloodworth, Charles H.
    Cochran, Richard P.
    Yoganathan, Ajit P.
    Kunzelman, Karyn S.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (04)
  • [5] Fluid-Structure Interaction Analysis of Bioprosthetic Heart Valve
    Shen, B. S.
    Yuan, Q.
    Zhang, X.
    Zhang, X.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND INFORMATION TECHNOLOGY (SEIT2015), 2016, : 118 - 122
  • [6] Fluid-structure interaction simulation of calcified aortic valve stenosis
    Cai, Li
    Hao, Yu
    Ma, Pengfei
    Zhu, Guangyu
    Luo, Xiaoyu
    Gao, Hao
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2022, 19 (12) : 13172 - 13192
  • [7] Effects of body posture on aortic valve hemodynamics and biomechanics using the fluid-structure interaction method
    Shu, Peng
    Li, Daochun
    Zhao, Shiwei
    Lv, Rui
    JOURNAL OF BIOMECHANICS, 2024, 177
  • [8] Fluid-Structure Interaction Simulation of Aortic Valve Closure with Various Sinotubular Junction and Sinus Diameters
    Pan, Youlian
    Qiao, Aike
    Dong, Nianguo
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (06) : 1363 - 1369
  • [9] An approach to the simulation of fluid-structure interaction in the aortic valve
    Carmody, CJ
    Burriesci, G
    Howard, IC
    Patterson, EA
    JOURNAL OF BIOMECHANICS, 2006, 39 (01) : 158 - 169
  • [10] Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation?
    Luraghi, Giulia
    Wu, Wei
    De Gaetano, Francesco
    Matas, Jose Felix Rodriguez
    Moggridge, Geoff D.
    Serrani, Marta
    Stasiak, Joanna
    Costantino, Maria Laura
    Migliavacca, Francesco
    JOURNAL OF BIOMECHANICS, 2017, 58 : 45 - 51