Bleeding assessment following central venous catheter placement, a direct comparison of prospective and retrospective analyses

被引:0
作者
van Baarle, Floor L. F. [1 ,2 ]
van de Weerdt, Emma K. [1 ,2 ]
Raasveld, S. Jorinde [1 ,2 ]
Vlaar, Alexander P. J. [1 ,2 ]
Biemond, Bart J. [3 ]
机构
[1] Amsterdam UMC Locat Univ Amsterdam, Dept Intens Care Med, Amsterdam, Netherlands
[2] Amsterdam UMC Locat Univ Amsterdam, Lab Expt Intens Care & Anesthesiol, Amsterdam, Netherlands
[3] Amsterdam UMC Locat Univ Amsterdam, Dept Hematol, Amsterdam, Netherlands
关键词
central venous catheter; hemorrhage; methodology; INTERRATER RELIABILITY; PLATELET TRANSFUSION;
D O I
10.1111/trf.17930
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundReported bleeding incidences following central venous catheter (CVC) placement highly depend on methods of bleeding assessment. To determine the direction and magnitude of the bias associated with retrospective data collection, we used data from the PACER randomized controlled trial and a previous retrospective cohort study.Study Design and MethodsA patient-level comparison of CVC-related bleeding severity was made among (1) the prospectively collected clinical bleeding assessment of the PACER trial, (2) centralized assessment of CVC insertion site photographs, and (3) retrospective chart review. Interrater reliability for photographic bleeding assessment and retrospective chart review was assessed using Cohen's kappa. The magnitude of underreporting of both methods compared to prospective clinical bleeding assessment at different cutoff points of clinically relevant bleeding was assessed using McNemar's test.ResultsInterrater reliability was acceptable for both methods (kappa = 0.583 and kappa = 0.481 for photographic assessment and retrospective chart review, respectively). Photographic bleeding assessment led to significant underreporting of bleeding complications at all cutoff points. Retrospective chart review led to significant underreporting of minor bleeding complications, with an odds ratio (95% CI) of 0.17 (0.044-0.51) for the cutoff point grade 1 (i.e., self-limiting or requiring at most 20 min of manual compression) or higher. There was no significant underreporting of major bleeding complications with retrospective chart review.DiscussionCentralized photographic bleeding assessment and retrospective chart review lead to biased bleeding assessment compared to prospective clinical bleeding assessment.
引用
收藏
页码:1414 / 1420
页数:7
相关论文
共 50 条
  • [21] Serious Gaming to Improve the Safety of Central Venous Catheter Placement
    Katz, Daniel
    DeMaria, Samuel
    ICT&A 2011/DEMSET 2011: INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES AND APPLICATIONS / INTERNATIONAL CONFERENCE ON DESIGN AND MODELING IN SCIENCE, EDUCATION, AND TECHNOLOGY, 2011, : 298 - 301
  • [22] The carina as a landmark for central venous catheter placement in small children
    Knut Albrecht
    Dirk Breitmeier
    Bernhard Panning
    Hans Dieter Tröger
    Heike Nave
    European Journal of Pediatrics, 2006, 165 : 264 - 266
  • [23] Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography
    Zanobetti, Maurizio
    Coppa, Alessandro
    Bulletti, Federico
    Piazza, Serena
    Nazerian, Peyman
    Conti, Alberto
    Innocenti, Francesca
    Ponchietti, Stefano
    Bigiarini, Sofia
    Guzzo, Aurelia
    Poggioni, Claudio
    Del Taglia, Beatrice
    Mariannini, Yuri
    Pini, Riccardo
    INTERNAL AND EMERGENCY MEDICINE, 2013, 8 (02) : 173 - 180
  • [24] Retrospective Assessment of Patient and Catheter Characteristics Associated With Malpositioned Central Venous Catheters in Pediatric Patients
    Weber, Mark D.
    Conlon, Thomas
    Woods-Hill, Charlotte
    Watts, Stephanie L.
    Nelson, Eileen
    Traynor, Danielle
    Zhang, Bingqing
    Davis, Daniela
    Himebauch, Adam S.
    PEDIATRIC CRITICAL CARE MEDICINE, 2022, 23 (03) : 192 - 200
  • [25] Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography
    Maurizio Zanobetti
    Alessandro Coppa
    Federico Bulletti
    Serena Piazza
    Peyman Nazerian
    Alberto Conti
    Francesca Innocenti
    Stefano Ponchietti
    Sofia Bigiarini
    Aurelia Guzzo
    Claudio Poggioni
    Beatrice Del Taglia
    Yuri Mariannini
    Riccardo Pini
    Internal and Emergency Medicine, 2013, 8 : 173 - 180
  • [26] Neonatal hydrothorax following migration of a central venous catheter
    Sridhar S.
    Thomas N.
    Kumar T S.
    Jana A.K.
    The Indian Journal of Pediatrics, 2005, 72 (9) : 795 - 796
  • [27] Assistive technology for ultrasound-guided central venous catheter placement
    Ikhsan, Mohammad
    Tan, Kok Kiong
    Putra, Andi Sudjana
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (01) : 41 - 57
  • [28] Assistive technology for ultrasound-guided central venous catheter placement
    Mohammad Ikhsan
    Kok Kiong Tan
    Andi Sudjana Putra
    Journal of Medical Ultrasonics, 2018, 45 : 41 - 57
  • [29] Central venous catheter placement during extracorporeal membrane oxygenation therapy
    Picard, Lucile
    Cherait, Chamsedine
    Constant, Ophelie
    Boulanger, Boris
    Dorget, Amandine
    Vodovar, Dominique
    Fiore, Antonio
    Haouache, Hakim
    Dhonneur, Gilles
    Mongardon, Nicolas
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2018, 37 (03) : 269 - 270
  • [30] Central venous catheter placement by an interventional radiology unit: An Australian experience
    Lee, M. K. S.
    Mossop, P. J.
    Vrazas, J. I.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (01): : 35 - 41