Evaluation of radiation detectors for the determination of field output factors in Leksell Gamma Knife dosimetry using 3D printed phantom inserts

被引:0
|
作者
Perrett, Ben [1 ]
Seshadri, Venkatakrishnan [1 ]
Huxley, Cosmo [2 ]
Kumar, Sanjay [3 ]
Wawrzak, Michal [1 ]
Ramachandran, Prabhakar [1 ]
机构
[1] Princess Alexandra Hosp, Radiat Oncol, 199 Ipswich Rd, Woolloongabba, Qld 4102, Australia
[2] 3DOne Australia Pty Ltd, 30 Nashos Pl, Wacol, Qld 4102, Australia
[3] Elekta Australia & New Zealand Pty Ltd, Suite 10-02,146 Arthur St, North Sydney, NSW 2060, Australia
关键词
Gamma Knife; microSilicon; microDiamond; RAZOR Nano; Small fields; Dosimetry; Field output correction factors; Field output factors; CRYSTAL DIAMOND DETECTOR; MONTE-CARLO; PERFEXION; RADIOSURGERY;
D O I
10.1016/j.ejmp.2024.103370
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Leksell Gamma Knife (R) PerfexionTM and IconTM have a unique geometry, containing 192 60Co sources with collimation for field sizes of 4 mm, 8 mm, and 16 mm. 4 mm and 8 mm collimated fields lack lateral charged particle equilibrium, so accurate field output factors are essential. This study performs field output factor measurements for the microDiamond, microSilicon, and RAZORTM Nano detectors. 3D printed inserts for the spherical Solid Water (R) Phantom were fabricated for microDiamond detector, the microSilicon unshielded diode and the RAZORTM Nano micro -ionisation chamber. Detectors were moved iteratively to identify the peak detector signal for each collimator, representing the effective point of measurement of the chamber. In addition, field output correction factors were calculated for each detector relative to vendor supplied Monte Carlo simulated field output factors and field output factors measured with a W2 scintillator. All field output factors where within 1.1 % for the 4 mm collimator and within 2.3 % for the 8 mm collimator. The 3D printed phantom inserts were suitable for routine measurements if the user identifies the effective point of measurement, and ensures a reproducible setup by marking the rotational alignment of the cylindrical print. Measurements with the microDiamond and microSilicon can be performed faster compared to the RAZORTM Nano due to differences in the signal to noise ratio. All detectors are suitable for field output factor measurements for the Leksell Gamma Knife (R) PerfexionTM and IconTM.
引用
收藏
页数:7
相关论文
共 35 条
  • [21] Using TLD measurements in a 3D printed phantom and patient SPECT/CT scans to evaluate semi Monte Carlo dosimetry software
    Wormgoor, Willem
    Meeuwis, Antoi
    Sechopoulos, Ioannis
    Hippelinen, Eero
    Sohlberg, Antti
    Visser, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [22] Dosimetry Evaluation of Treatment Planning Systems in Patient-Specific 3D Printed Anthropomorphic Phantom for Breast Cancer after Mastectomy using a Single-Beam 3D-CRT Technique for Megavoltage Electron Radiation Therapy
    Endarko E.
    Aisyah S.
    Hariyanto A.P.
    Haekal M.
    Kavilani N.
    Syafi’i A.
    Journal of Biomedical Physics and Engineering, 2023, 13 (03): : 217 - 226
  • [23] Feasibility of Out-Of-Field Dosimetry in Photon, Proton, and Neutron Therapies Using a 3D-Printed Patient-Specific Phantom
    Tillery, H.
    Moore, M.
    Leuro, E.
    Argento, D.
    Moffitt, G.
    Taddei, P.
    Newhauser, W.
    Kranz, M.
    Gallagher, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E325 - E326
  • [24] Evaluation of dose profiles using Gafchromic EBT3 films in Leksell Gamma Knife 4C around inhomogeneities in the treatment of pituitary adenoma in anthropomorphic heterogeneous head phantom
    Najafi, M.
    Shirazi, A.
    Geraily, Gh.
    Esfahani, M.
    Teimouri, J.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 149 : 104 - 109
  • [25] Near-field clutter artifact reduction algorithm based on wavelet thresholding method in echocardiography using 3D printed cardiac phantom
    Kim, Minkyoung
    Han, Dong-Kyoon
    Lee, Youngjin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (05) : 441 - 449
  • [26] Near-field clutter artifact reduction algorithm based on wavelet thresholding method in echocardiography using 3D printed cardiac phantom
    Minkyoung Kim
    Dong-Kyoon Han
    Youngjin Lee
    Journal of the Korean Physical Society, 2022, 81 : 441 - 449
  • [27] Dosimetric Validation of Mask-Based Stereotactic Gamma Knife Radiosurgery Using Pseudo in Vivo 3D Dosimetry: End-To-End SRS Quality Assurance
    Osterman, K.
    Storey, P.
    Pappas, E.
    Kondziolka, D.
    Silverman, J.
    Das, I.
    Xu, A.
    Xue, J.
    Han, K.
    Lymberis, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2953 - 2953
  • [28] Small-field dosimetry with a high-resolution 3D scanning water phantom system for the small animal radiation research platform SARRP: a geometrical and quantitative study
    Arango, Erika Munoz
    Peixoto, Jose Guilherme
    de Almeida, Carlos Eduardo
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01):
  • [29] Comparing phase- and amplitude-gated volumetric modulated arc therapy for stereotactic body radiation therapy using 3D printed lung phantom
    Lee, Minsik
    Yoon, KyoungJun
    Cho, Byungchul
    Kim, Su Ssan
    Song, Si Yeol
    Choi, Eun Kyung
    Ahn, SeungDo
    Lee, Sang-Wook
    Kwak, JungWon
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (02): : 107 - 113
  • [30] Evaluation of a no-reference image quality metric for projection X-ray imaging using a 3D printed patient-specific phantom
    Buytaert, Dimitri
    Taeymans, Yves
    De Wolf, Daniel
    Bacher, Klaus
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 29 - 40