Effects of diameters of implant and abutment screw on stress distribution within dental implant and alveolar bone: A threedimensional finite element analysis

被引:5
作者
Shen, Yen -Wen [1 ,2 ]
Huang, Heng-Li [1 ,3 ,4 ]
Hsu, Jui-Ting [1 ,3 ]
Fuh, Lih-Jyh [1 ,2 ]
机构
[1] China Med Univ, Sch Dent, 91 Hsueh Shih Rd, Taichung 40402, Taiwan
[2] China Med Univ Hosp, Dept Dent, Taichung, Taiwan
[3] China Med Univ, Dept Biomed Engn, Taichung, Taiwan
[4] Asia Univ, Dept Bioinformat & Med Engn, Taichung, Taiwan
关键词
Abutment screw; Implant diameter; Bone; Stress; Finite element analysis; QUALITY;
D O I
10.1016/j.jds.2023.12.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Few studies have investigated the effects of abutment screw diameter in the stress of dental implants and alveolar bones under occlusal forces. In this study, we investigated how variations in implant diameter, abutment screw diameter, and bone condition affect stresses in the abutment screw, implant, and surrounding bone. Materials and methods: Three-dimensional finite element (FE) models were fabricated for dental implants with external hex -type abutments measuring 4 and 5 mm in diameter. The models also included abutment screws measuring 2.0 and 2.5 mm in diameter. Each implant model was integrated with the mandibular bone comprising the cortical bone and four types of cancellous bone. In total, 12 finite element models were generated, subjected to three different occlusal forces, and analyzed using FE software to investigate the stress distribution of dental implant and alveolar bone. Results: Wider implants demonstrated lower stresses in implant and bone compared with standard -diameter implants. The quality of cancellous bone has a minimal impact on the stress values of the implant, abutment screw, and cortical bone. Regardless of occlusal arrangement or quality of cancellous bone, a consistent pattern emerged: larger abutment screw diameters led to increased stress levels on the screws, while the stress levels in both cortical and cancellous bone showed comparatively minor fluctuations. Conclusion: Wider implants tend to have better stress distribution than standard -diameter implants. The potential advantage of augmenting the abutment screw diameter is unfavorable. It may result in elevated stresses in the implant system. <feminine ordinal indicator> 2024 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY -NC -ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1126 / 1134
页数:9
相关论文
共 50 条
  • [41] Effect of Different Implant-Abutment Mismatches on Stress Distribution: A 3-Dimensional Finite Element Study
    Esfahanian, Vahid
    Khosravi, Armin
    Ketabi, Mohammad
    Deporter, Douglas
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (05) : 370 - 374
  • [42] Stress Analysis in Anterior Single Unit Implant with Different Abutment Connection Designs: A Finite Element Study
    Kumma, Pattamapom
    Sareekuea, Patcharee
    Iadnagkhan, Panupong
    Puengpaiboon, Usanee
    Rattanapan, Nichapat
    Kunarak, Piriya
    Sukjamsri, Chamaipom
    2023 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND APPLICATIONS, ICBEA, 2023, : 93 - 97
  • [43] Implant-Bone Interface Stress Distribution in Immediately Loaded Implants of Different Diameters: A Three-Dimensional Finite Element Analysis
    Ding, Xi
    Zhu, Xing-Hao
    Liao, Sheng-Hui
    Zhang, Xiu-Hua
    Chen, Hong
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05): : 393 - 402
  • [44] Finite Element Analysis of the Influence of Implant Inclination on Stress Distribution in Mandibular Overdentures
    Ebadian, Behnaz
    Mosharraf, Ramin
    Khodaeian, Niloufar
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : 252 - 257
  • [45] Finite Element Analysis (FEA) for Influence of Variation in Dental Implant Dimensions (Length and Diameter) on Peri-implant Bone Stress/Strain Distribution: A Systematic Review
    Sayed, Arshad Jamal
    Mohsin, Syed Fareed
    Garg, Kamlesh Kumar
    Agwan, Muhammad Atif Saleem
    Tareen, Sabahat Ullah Khan
    Alruthea, Mohammed Sulaiman
    Mohan, Sasankoti
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2025, 41 (01) : 318 - 330
  • [46] Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone
    Schwitalla, A. D.
    Abou-Emara, M.
    Spintig, T.
    Lackmann, J.
    Mueller, W. D.
    JOURNAL OF BIOMECHANICS, 2015, 48 (01) : 1 - 7
  • [47] Assessment of Stress Shielding around a Dental Implant for Variation of Implant Stiffness and Parafunctional Loading using Finite Element Analysis
    Ishak, Muhammad Ikman
    Daud, Ruslizam
    Noor, Siti Noor Fazliah Mohd
    Khor, C. Y.
    Roslan, Husniyati
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2022, 24 (03) : 147 - 159
  • [48] Stress Distribution due to Loading on Premolar Teeth Implant: A Three Dimensional Finite Element Analysis
    Hisam, M. J.
    Lim, J. Y.
    Kurniawan, D.
    Nor, F. M.
    2ND INTERNATIONAL MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING CONFERENCE, MIMEC2015, 2015, 2 : 218 - 223
  • [49] Three-Dimensional Finite Element Analysis of Stress Distribution in Dental Implant Prosthesis and Surrounding Bone Using PEEK Abutments
    Hong, Min-Ho
    Choi, Hyunsuk
    BIOMIMETICS, 2024, 9 (08)
  • [50] Nonlinear finite element analysis of three implant-abutment interface designs
    Tang, Chun-Bo
    Liu, Si-Yu
    Zhou, Guo-Xing
    Yu, Jin-Hua
    Zhang, Guang-Dong
    Bao, Yi-Dong
    Wang, Qiu-Ju
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2012, 4 (02) : 101 - 108