Comparative Analysis of 500 kV Double-Circuit Transmission Line Electric Field Intensity: Ethiopian Lines Compliance With ICNIRP

被引:1
|
作者
Tefera, Tesfaye Nafo [1 ]
Punekar, Gururaj S. [2 ]
Yassin, Kemal Ibrahim [1 ]
Tuka, Milkias Berhanu [1 ]
机构
[1] Addis Ababa Sci & Technol Univ, Dept Elect & Comp Engn, Addis Ababa 1000, Ethiopia
[2] Natl Inst Technol Karnataka, Dept Elect & Elect Engn, Surathkal 575025, India
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Conductors; Power transmission lines; Poles and towers; Wires; Mathematical models; Electric fields; High-voltage techniques; Radiation protection; CSM; double-circuit 500 kV lines; E-field; INCIRP guideline; phase sequence arrangement; tower configuration; VOLTAGE;
D O I
10.1109/ACCESS.2024.3406902
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The high-intensity electric fields, which are in the vicinity of power transmission lines, have adverse effects on human and other living beings if they are not within the specified limits. The International Commission on Non-ionizing Radiation Protection (INCIRP) specifies guidelines for these E-fields from the perspective of public exposure at the ground level and sets it to 5 kV/m at 50 Hz. Thus, this study was aimed at analyzing and comparing the E-fields intensity of differently configured double-circuit 500 kV transmission lines at a height of 1 m above the ground plane. Charge Simulation Method (CSM) using MATLAB as a programming platform is used for this study. Among the tower configurations studied, a configuration that provided minimum E-fields with minimum ground clearance was identified. From the actual built transmission lines included in the study, vertical lines configuration produces a minimum E-fields intensity of 4.565 kV/m root mean square and fulfills the INCIRP requirement. However, triangular line configuration is the preferable configuration for 500 kV double circuit transmission lines giving the least E-fields at the ground with minimum ground clearance using optimized phase sequence arrangements irrespective of other comparative parameters. Additionally, an evaluation of these line configurations based on the distribution of the conductor surface E-fields was conducted. The study reveals that the E-fields on the surface of the transmission line conductors included in the study remains significantly below the intrinsic breakdown strength of atmospheric air. Therefore, it was anticipated that the designs will remain free from corona discharge under fair weather conditions.
引用
收藏
页码:76359 / 76366
页数:8
相关论文
共 50 条
  • [1] Distribution of Magnetic Field in 400 kV Double-Circuit Transmission Lines
    Deltuva, Ramunas
    Lukocius, Robertas
    APPLIED SCIENCES-BASEL, 2020, 10 (09):
  • [2] The analysis of Body Surface Electric Field during Live Working on 500kV double-circuit lines on same tower
    Liu, Xiaqin
    Yang, Qi
    Li, Hui
    Chen, Jianping
    Li, Jinliang
    Xu, Li
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [3] A calculation method for the electric field under double-circuit HVDC transmission lines
    Yang, Yong
    Lu, Jiayu
    Lei, Yinzhao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1736 - 1742
  • [4] Analysis of Safety Protection Measures for Maintenance Work of 500 kV Double-Circuit Transmission Lines on Same Tower
    Yang, Qi
    Zou, Dehua
    Zhang, Jianjun
    Li, Hui
    Chen, Jianping
    Li, Jinliang
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [5] Research on electromagnetic environment of ±800 kV and ±500 kV double-circuit DC transmission lines on the same tower
    Wu, Gaobo
    Li, Jian
    Chen, Yuan
    Luo, Chujun
    Wang, Rusong
    Lin, Fang
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2532 - 2538
  • [6] Application of line surge arresters to double-circuit transmission lines
    Institute of Industrial Science, University of Tokyo, Tokyo, Japan
    不详
    Int. Symp. Light. Prot., XI SIPDA, 2011, (312-318):
  • [7] Lightning performance of 500 kV double-circuit line on same tower of the Three Gorges outgoing lines
    Huang, Weigang
    Zhongguo Dianli/Electric Power, 2000, 33 (05): : 57 - 61
  • [8] Study on Simulating Test of Total Electric Field of Double-Circuit DC Transmission Line
    Ju Yong
    Lu Jiayu
    Zhang Wenliang
    Han Hui
    Jiang Jun
    Xue Chendong
    Zhao Peng
    Qu Xuedi
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 263 - 271
  • [9] Calculation of the total electric field at ground level for double-circuit HVDC overhead transmission lines
    Department of Electrical Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2008, 6 (32-36):
  • [10] Electric Field Distribution Calculation and Analysis of Composite Insulators Operating on Double Circuit Transposition Tower in 500kV Transmission Lines
    Guo, Chenjun
    Liu, Lishuai
    Yu, Hong
    Ma, Yi
    Mei, Hongwei
    Wang, Liming
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 486 - 489