Influence of Sutureless Scleral Fixation Techniques With 3-Piece Intraocular Lenses on Dislocation Force

被引:1
|
作者
Zeilinger, Johannes [1 ]
Kronschlaeger, Martin [1 ]
Schlatter, Andreas [1 ]
Ruiss, Manuel [1 ]
Bayer, Natascha [1 ]
Findl, Oliver [1 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg VIROS, Karl Landsteiner Inst, Vienna, Austria
关键词
EYES; EXTERNALIZATION; COMPLICATIONS; IMPLANTATION; OUTCOMES;
D O I
10.1016/j.ajo.2024.03.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To compare 4 different secondary intraocular lens (IOL) fixation techniques regarding the least required force to dislocate a scleral fixated 3-piece IOL in human corneoscleral donor tissue. center dot DESIGN: Experimental laboratory investigation. center dot METHODS: The least required dislocation force (LRDF) of 4 different secondary IOL fixation techniques, namely, the techniques using transscleral tunnels (TTs; as described by Scharioth), glued haptics (GHs; Agarwal), flanged haptics (FHs; Yamane), and bent haptic ends (BH; Behera/Bolz), were investigated using 40 threepiece IOLs (Sensar AR40) fixated to human scleral tissue. The main outcome of the study, dislocation force between different techniques, was measured with a tensiometer. center dot RESULTS: The force needed to dislocate the haptics was highest with the FH technique and was significantly higher than with all the other techniques (GH vs FH: - 1.02 +/- 0.02 N, P < .001; TT vs FH: -1.08 +/- 0.21 N, P < .001; BH vs FH: -1.00 +/- 0.25 N, P = .044). There was no significant difference regarding the dislocation force between the other techniques: GH vs TT (-0.06 +/- 0.100 N, P = .988), GH vs BH (-0.02 +/- 0.03 N, P = .60), TT vs BH (-0.08 +/- 0.04 N, P > .99). center dot CONCLUSIONS: The FH technique as described by Yamane proved to be the strongest form of secondary IOL fixation regarding dislocation force in this in vitro study. The other fixation techniques showed significantly less resistance to axial traction. (Am J Ophthalmol 2024;264: 229-234. (c) 2024 Elsevier Inc. All rights reserved.)
引用
收藏
页码:229 / 234
页数:6
相关论文
共 50 条
  • [11] Anterior segment parameters: Comparison of 1-piece and 3-piece acrylic foldable intraocular lenses
    Behrouz, Mahmoud Jabbarvand
    Kheirkhah, Ahmad
    Hashemian, Hesam
    Nazari, Rahman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1650 - 1655
  • [12] Clinical outcomes of iris fixation and sutureless scleral fixation of dislocated foldable posterior chamber intraocular lenses
    Aydin, E.
    Kazanci, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (08):
  • [13] A New Technique with Scleral Grooves for Sutureless Scleral Fixation of the Carlevale Intraocular Lens
    Giannopoulos, Theodoros
    Panagiotou, Evangelia S.
    Giannoukaki, Aikaterini
    Mikropoulos, Dimitrios G.
    Konstas, Anastasios G.
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2255 - 2263
  • [14] Transconjunctival Sutureless Intrascleral Fixation of Secondary Intraocular Lenses in Patients with Uveitis
    Todorich, Bozho
    Thanos, Aristomenis
    Yonekawa, Yoshihiro
    Thomas, Benjamin J.
    Abbey, Ashkan M.
    Faia, Lisa J.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2018, 26 (03) : 456 - 460
  • [15] Sutureless scleral intraocular lens fixation: Report of nine cases and literature review
    Benayoun, Y.
    Petitpas, S.
    Turki, K.
    Adenis, J-P
    Robert, P-Y
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2013, 36 (08): : 658 - 668
  • [16] Comparison of sutured versus sutureless scleral-fixated intraocular lenses
    Sindal, Manavi D.
    Nakhwa, Chinmay P.
    Sengupta, Sabyasachi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 27 - 34
  • [17] Pathologic Comparison of Asymmetric or Sulcus Fixation of 3-Piece Intraocular Lenses with Square Versus Round Anterior Optic Edges
    Ollerton, Andrew
    Werner, Liliana
    Strenk, Susan
    Strenk, Lawrence
    Leishman, Lisa
    Bodnar, Zachary
    Kirk, Kevin R.
    Michelson, Jennifer
    Mamalis, Nick
    OPHTHALMOLOGY, 2013, 120 (08) : 1580 - 1587
  • [18] Intraocular lens capture in combined cataract extraction and pars plana vitrectomy: Comparison of 1-piece and 3-piece acrylic intraocular lenses
    Rudnisky, Christopher J.
    Cheung, Joseph
    Nanji, Jalal A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1645 - 1649
  • [19] Single-suture scleral fixation of subluxated foldable intraocular lenses
    Yarangumeli, Alper
    Alp, Mehmet Numan
    Kural, Gulcan
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (04) : 547 - 553
  • [20] Enhanced surgical technique for sutureless intrascleral fixation of intraocular lenses
    Gabai, Andrea
    Zeppieri, Marco
    Toneatto, Giacomo
    Salati, Carlo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : E75 - E79