The effect of electron backscatter and charge build up in media on beam current transformer signal for ultra-high dose rate (FLASH) electron beam monitoring

被引:2
|
作者
Pageot, Charles [1 ,2 ]
Zerouali, Karim [2 ]
Guillet, Dominique [2 ]
Muir, Bryan [3 ]
Renaud, James [3 ]
Lalonde, Arthur [2 ,4 ,5 ]
机构
[1] Ecole Polytech Montreal, Montreal, PQ, Canada
[2] Ctr Hosp Univ Montreal CHUM, Montreal, PQ, Canada
[3] CNR, Ottawa, ON, Canada
[4] Univ Montreal, Montreal, PQ, Canada
[5] Ctr Rech Ctr Hosp Univ Montreal CRCHUM, Montreal, PQ, Canada
关键词
ultra-high dose rate radiotherapy; flash radiotherapy; beam current transformer; electron UHDR radiotherapy; charge build-up; HIGH-ENERGY PHOTON; PHANTOM MATERIAL; IRRADIATION; CHAMBER; STORAGE; CELLS; WATER;
D O I
10.1088/1361-6560/ad40f7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Beam current transformers (BCT) are promising detectors for real-time beam monitoring in ultra-high dose rate (UHDR) electron radiotherapy. However, previous studies have reported a significant sensitivity of the BCT signal to changes in source-to-surface distance (SSD), field size, and phantom material which have until now been attributed to the fluctuating levels of electrons backscattered within the BCT. The purpose of this study is to evaluate this hypothesis, with the goal of understanding and mitigating the variations in BCT signal due to changes in irradiation conditions. Approach. Monte Carlo simulations and experimental measurements were conducted with a UHDR-capable intra-operative electron linear accelerator to analyze the impact of backscattered electrons on BCT signal. The potential influence of charge accumulation in media as a mechanism affecting BCT signal perturbation was further investigated by examining the effects of phantom conductivity and electrical grounding. Finally, the effectiveness of Faraday shielding to mitigate BCT signal variations is evaluated. Main Results. Monte Carlo simulations indicated that the fraction of electrons backscattered in water and on the collimator plastic at 6 and 9 MeV is lower than 1%, suggesting that backscattered electrons alone cannot account for the observed BCT signal variations. However, our experimental measurements confirmed previous findings of BCT response variation up to 15% for different field diameters. A significant impact of phantom type on BCT response was also observed, with variations in BCT signal as high as 14.1% when comparing measurements in water and solid water. The introduction of a Faraday shield to our applicators effectively mitigated the dependencies of BCT signal on SSD, field size, and phantom material. Significance. Our results indicate that variations in BCT signal as a function of SSD, field size, and phantom material are likely driven by an electric field originating in dielectric materials exposed to the UHDR electron beam. Strategies such as Faraday shielding were shown to effectively prevent these electric fields from affecting BCT signal, enabling reliable BCT-based electron UHDR beam monitoring.
引用
收藏
页数:18
相关论文
共 23 条
  • [21] Pencil Beam Scanning Bragg Peak FLASH Technique for Ultra-High Dose Rate Intensity-Modulated Proton Therapy in Early-Stage Breast Cancer Treatment
    Lattery, Grant
    Kaulfers, Tyler
    Cheng, Chingyun
    Zhao, Xingyi
    Selvaraj, Balaji
    Lin, Haibo
    Simone II, Charles B.
    Choi, J. Isabelle
    Chang, Jenghwa
    Kang, Minglei
    CANCERS, 2023, 15 (18)
  • [22] Design and validation of a dosimetric comparison scheme tailored for ultra-high dose-rate electron beams to support multicenter FLASH preclinical studies
    Jorge, Patrik Goncalves
    Melemenidis, Stavros
    Grilj, Veljko
    Buchillier, Thierry
    Manjappa, Rakesh
    Viswanathan, Vignesh
    Gondre, Maude
    Vozenin, Marie-Catherine
    Germond, Jean-Francois
    Bochud, Francois
    Moeckli, Raphael
    Limoli, Charles
    Skinner, Lawrie
    No, Hyunsoo Joshua
    Wu, Yufan Fred
    Surucu, Murat
    Yu, Amy S.
    Lau, Brianna
    Wang, Jinghui
    Schuler, Emil
    Bush, Karl
    Graves, Edward E.
    Maxim, Peter G.
    Loo, Billy W., Jr.
    Bailat, Claude
    RADIOTHERAPY AND ONCOLOGY, 2022, 175 : 203 - 209
  • [23] A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
    Wei, Shouyi
    Lin, Haibo
    Choi, J. Isabelle
    Simone, Charles B., II
    Kang, Minglei
    CANCERS, 2021, 13 (22)